HFC, DOCSIS Maintenance and Service Meter: Oneexpert CATV

HFC, DOCSIS Maintenance and Service Meter: Oneexpert CATV

VIAVI Solutions Data Sheet VIAVI OneExpert CATV A full-featured handheld for technicians at any skill level OneExpertTM CATV helps field technicians fix problems right— the first time. A technician-friendly interface and OneCheck™ automated tests ease complex tasks with a simple dashboard that shows clear pass/fail results. And its future-proof modularity ensures years of use supporting CATV networks. Comprehensive Tools Increase Productivity Benefits We built expertise into OneExpert so that technicians at y Simplifies and speeds testing and any skill level can quickly optimize performance. With a troubleshooting modular platform that adapts easily to rapidly changing y Improves compliance and audit performance technologies, OneExpert CATV is: y Reduces rework y Simple — Auto channel identification eliminates y Turns any technician into an expert channel plan build, maintenance, and deployment Features overhead and enables automated testing without the y Real-time channel identification eliminates the potential for channel plan related test failures need for channel plans and plan-related errors y Fast — OneCheck uses powerful processing and y 32x8 DOCSIS® 3.0, DOCSIS 3.1, WiFi, 1 Gigabit exceptional speed to make more complete testing Ethernet capable, and TrueSpeed™ option practical: a tech can run a comprehensive test, y Field-exchangeable DOCSIS/RF module including MER and BER on all channels, in about y A unique dual-diplexer design supports a minute transition to extended return band y WiFi 2.4/5 GHz, wireless personal area network, y Powerful — More intelligent, powerful algorithms and StrataSync™ enabled running in the background while testing enables the y Simultaneous ingress and downstream testing meter to point out any problems and suggest next y Optional fiber scope and power meter troubleshooting steps y Optional ISDB-T Module Applications y Troubleshooting QAM carriers/home networks y Verifying WiFi in 2.4 GHz and 5 GHz networks Now with y Testing Gigabit DOCSIS services y Installing PON/RFoG including inspection, DOCSIS 3.1 power levels, and RF performance y Optional QAM video MPEG analysis for RPD activation y Optional home leakage testing y Network maintenance with forward and reverse sweep Specifications Frequency Range Upstream Analysis — Port 2 Automatically Ingress 0.5 – 204 MHz Switching Upstream Downstream spectrum Diplexer scan 4-42 MHz and 54-1,004 MHz and Sensitivity −45 dBmV 42/85 4-85 MHz 108-1,218 MHz RBW 300 kHz 4-42 MHz and 54-1,004 MHz and Min −55 dBmV 42/204 MHz 4-204 MHz 258-1,218 MHz detectable level 4-65 MHz and 83-1,218 MHz and 65/204 upstream 4-204 MHz 258 MHz-1,218 MHz Dynamic ONX-630 – 60dB; ONX-620 – 50dB ±10 ppm typical Accuracy range @25°C Max total 55 dBmV, 4 – 10 MHz; 60 dBmV, 10 to Downstream Analysis — Port 1 integrated 204 MHz AutoChannel Auto detection of channel parameters power plan builder (analog/digital, symbols, QAM) Accuracy ±2 dB typical at 25°C Max input TM 60 dBmV total integrated power Sampling rate Hyper Spectrum FFT gapless power technology - no missed samples, spans Operation on Operate with up to 90 V AC/DC on 0.5 -110 MHz, 110 to 160 MHz, and 160 powered tap input port to 204 MHz Power Notify of AC/DC power presence on Return loss >9.5 dB detection/ port 2 above 2 Volts Operation on Operate with up to 90 V AC/DC on notification powered tap input port Return loss >9 dB Power Notify of AC/DC power presence on detection/ port 2 notification above 2 Volts Upstream Signal Generator Number From 1 to 8 of signals generated simultaneously Signal types signals either all CW or all modulated Modulation QPSK, 16 QAM, and 64 QAM supported Symbol rates 5.12, 2.56, 1.28, 0.64, 0.32, and 0.16 supported Msym/s 2 VIAVI OneExpert™ CATV Data Sheet Specifications Continued Analog Channel Measurement Hum Specification Video and audio levels (dual) Hum frequency 25 Hz to 1000 Hz Standards NTSC , PAL, SECAM range Min −50 dBmV (single channel) Minimum MER 33 dB detectable Accuracy up to +/- 0.8% signal 5% hum Level accuracy ±1.5 dB from −20 dBmV to +50 dBmV From 5 to 10% +/- 1.0% typical at 25°C; ±2.0 dB, −10°C to OFDM Signal Performance Metrics +50°C OFDM Channels 24 - 192 MHz wide - up to 3 RBW 300 kHz active OFDM channels Carrier to Noise Level — max, min, relative to a 6 MHz carrier per Channel types NTSC , PAL, SECAM, non-scrambled average, standard CableLabs© Range 30 to 51 dB deviation (NTSC, 4 MHz measurement MER — max, 12 to 50 dB bandwidth) min, average, Required 0 to +40 dBmV with 77 analog standard deviation, input level channels present, maximum ±15 dB tilt percentile 50 to 1,000 MHz MER channel band max, min, avg across entire OFDM Accuracy ±2.0 dB within specified measurement graph carrier range Noise max ≤ 600 MHz Echo dBc Downstream Digital Channel Analysis ICFR in-carrier frequency response (dB) Calibrated -20 dBmV to +50 dBmV Spectrum/IUC spectrum display, including carrier power levels and ingress under carrier Level accuracy ±1.5 dB from -20 dBmV to +50 dBmV OFDM Profile Analysis typical at 25°C; ±2.0 dB, -10°C to Profiles A, B, C, D, NCP, and PLC +50°C (more profiles as implemented) Modulation(s) 64, 128, and 256 QAM, OFDM Lock status, codeword errors Annex A: 5.057 to 6.952 MSPS (corrected and uncorrected) Annex B: 5.057 for 64 QAM and 5.361 MSPS for 256 DOCSIS Testing QAM Supports DOCSIS 3.1 bonding up to 32 SC-QAM + 2 Annex C: 5.274 MSPS for 64 QAM and 5.361 MSPS for OFDM downstream channels, 8 SC-QAM + 2 OFDMA 256 QAM upstream channels Regional DVB-C Compliant with CableLabs® specifications for DOCSIS demods 3.1 Full span MER Compliant with CableLabs® specifications for DOCSIS Ingress under carrier — full span ingress noise trace 3.0 (32x8 bonding) Group delay and in-channel frequency response (ICFR) Digital quality index (DQI) over time Errored/severely errored seconds Level, measured symbol rate, carrier frequency, modulation, interleaver depth 3 VIAVI OneExpert™ CATV Data Sheet Specifications Continued Displayed DOCSIS Results MER Top level Number of bonded channels, min Specified range1 21 to 40 dB, 64 QAM; 28 to 40 dB, receive level, max BER (pre-FEC), (with input level 256 QAM; 16 to 44 dB OFDM min and max MER, max transmit -5 to +20 dBmV) level, max ICFR (in-channel Max displayable 50 dB frequency response) range Details Downstream SC-QAM (over time Resolution 0.1 dB charts: level, MER, BER, DQI), Accuracy ±2 dB typical at 25°C Upstream (charts: transmit over Minimum lock level −15 dBmV time, upstream ICFR, upstream BER — Down to 1E-9 (pre and post FEC) EQ taps ChannelCheck Service tests Registration, Throughput, Ping/ and DOCSISCheck Traceroute, Packet Quality; cable mode modem pass-through BER — OneCheck Down to 1E-8 (pre and post FEC) OFDM OFDM selected in scan, number mode default; 1E-9 user selectable of subcarriers, PLC lock status, Interleaver depth 128, 8 max frequency, level, and MER, CWE (corr, uncorr); OFDM channel(s) - Display/Interface/Usability Level variation (max, min, avg), High-brightness 5 inch diagonal MER variation (max, min, avg), color LCD (800 x ICFR, profile analysis (locked, CWE 480) corr, CWE uncorr) Touch screen Capacitive Downstream Hard key navigation capable Frequency range 54/85/108/258 to 1,000/1,218 MHz Boot time Approximately 20 sec (dependent on currently active Environmental diplexer frequency) For indoor/outdoor IP 54 light rain (0.5 in/hr; 1.27 cm/ Upstream use hr) Frequency range 5 to 204 MHz (dependent Pollution 2° on currently active diplexer Drop 1 m (3.3 ft) onto concrete frequency) Temp range Operating −10 to 50°C OFDMA channels ≥2, per DOCSIS specification (14 to 122°F) Transmit level +61 to +48 dBmV depending on Storage −20 to 60°C range (max) modulation format and number temp (-4 to 140°F) of bonded carriers, per DOCSIS Humidity 10 – 90% RH non-condensing specification RF immunity 8.5 V/m (for CATV measurements) SC-QAM channels up to 8 per DOCSIS specification Maximum altitude 4000 m (13,123 ft) 1MER range declines as input levels decrease. Expected MER range at MIN LOCK level of –15 dBmV. 4 VIAVI OneExpert™ CATV Data Sheet Specifications Continued Input/Outputs Weight RF (2) F connectors replaceable ONX-620 & ONX- 5.95 lb (2.7 kg) Port 1 Downstream 54/85/108/258 MHz 630 depending on diplexer Protective case and 0.95 lb Port 2 Upstream 4 – 204 MHz and TDR shoulder strap USB host (2) WiFi Ethernet (2) RJ45 10/100/1000T Test interface 802.11 a/b/g/n (2.4/5 GHz) Power Polarized Tests WiFi scan; WiFi access point (2.4 Remote Access/Connectivity GHz only) VNC accessible via IP address Scan results SSID (secure set identification); HTTPS file access via IP address Channel; Security setting; Power Mobile application via wireless personal area network level; MAC address Battery Scan modes AP list (access point); Channel graph; Field replaceable 96 W/hr 10.4 V, 10-cell LiIon Time graph Typical battery life 6 – 8 hr continuous, 15 – 20 hr Access point (IPX, Configure OneExpert CATV as typical usage TSX models only) WiFi access point (Ethernet to Battery charge 4 Hrs (90%) 6 - 8 Hrs 100% (AC WiFi bridge) time charger) StrataSync Reporting Capability Session based (job/work order) file saving of results gathered at TAP, GB, and CPE Measurement screen capture save and recall StrataSync Core Asset and data management StrataSync Plus Optional extended data management (6 years) Warranty Mainframe and 3-yr warranty (See http://www.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    14 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us