Genetically Encoded Neural Activity Indicators

Genetically Encoded Neural Activity Indicators

CONEUR-1001; NO. OF PAGES 6 Available online at www.sciencedirect.com Genetically encoded neural activity indicators 1 2 Loren L Looger and Oliver Griesbeck Recording activity from identified populations of neurons is a brane depolarization and ion flux to downstream signal central goal of neuroscience. Changes in membrane transduction cascades. Critically, genetically encoded depolarization, particularly action potentials, are the most indicators facilitate targeted long-term expression with important features of neural physiology to extract, although repeated observation of individual cells, to address ques- ions, neurotransmitters, neuromodulators, second tions of nervous system development and maintenance, messengers, and the activation state of specific proteins are learning and memory. Here we review recent progress in also crucial. Modern fluorescence microscopy provides the neural activity indicator engineering, and highlight basis for such activity mapping, through multi-photon imaging important results and approaches. and other optical schemes. Probes remain the rate-limiting step for progress in this field: they should be bright and photostable, Membrane potential and ideally come in multiple colors. Only protein-based Although it is a more ‘fundamental’ signal in neuro- reagents permit chronic imaging from genetically specified science, membrane potential (‘voltage’) imaging has been cells. Here we review recent progress in the design, notoriously difficult [6]. Small molecule probes (‘voltage- optimization and deployment of genetically encoded indicators sensitive dyes’, VSDs) have been in use for nearly three for calcium ions (a proxy for action potentials), membrane decades [7], but none has sufficient performance to potential, and neurotransmitters. We highlight seminal achieve common usage. VSDs are typically quite hydro- experiments, and present an outlook for future progress. phobic, which makes them difficult to load; toxicity has Addresses also been a problem. The nature of the underlying voltage 1 Howard Hughes Medical Institute, Janelia Farm Research Campus, signal makes imaging it inherently troublesome: action Ashburn, VA 20147, USA potentials persist on a scale of 1–5 ms, and are quite 2 Max-Planck-Institut fu¨ r Neurobiologie, Am Klopferspitz 18, 82152 local. This means that cellular-resolution voltage imaging Martinsried, Germany must be performed with both high temporal and spatial Corresponding authors: Looger, Loren L ([email protected]) and resolution; this in turn limits photon budget, which chal- Griesbeck, Oliver ([email protected]) lenges signal-to-noise ratio (SNR). In the end, voltage imaging is commonly practiced as a ‘bulk imaging’ tech- nique, to determine the relative activity of largish cellular Current Opinion in Neurobiology 2011, 22:1–6 aggregates; at the other extreme, single cells are loaded with VSDs through a patch pipette. The former fails to This review comes from a themed issue on Neurotechnology take advantage of the features of the voltage signal, and Edited by Winfried Denk and Gero Miesenbo¨ ck falls within the purview of calcium imaging (see next section). The latter cannot address systems neuroscience questions. 0959-4388/$ – see front matter Published by Elsevier Ltd. The first genetically encoded voltage indicator (GEVI) was developed in 1997 [8], the same year as the first DOI 10.1016/j.conb.2011.10.024 GECI. In spite of this, none has yet been used for other than ‘proof-of-principle’ experiments, owing to poor properties. Early indicators, such as FlaSh [8], SPARC Introduction [9], and VSFP1 [10], were based either on intact voltage- The injection of aequorin purified from jellyfish [1] into gated potassium channels, or their ‘voltage paddle’ the barnacle muscle fiber [2] heralded the beginning of domains. Such indicators had poor membrane targeting, protein-based indicators of neural activity. The ‘DNA low SNR, slow kinetics, and caused cytotoxicity [11]. The revolution’ quickly led to the cloning of the aequorin next generation of GEVIs was based on the paddle gene and its partner green fluorescent protein (GFP). domain of a voltage-gated phosphatase, CiVSP [12]. Such Several years later, the first genetically encoded calcium probes have dramatically improved targeting and toxicity indicators (GECIs), produced by the host organism, were profiles, and marginally improved SNR, but remain slow, introduced [3,4]. The parallel development of fluor- on the order of current GECIs [13,14]. Two-photon escence microscopy, most notably multi-photon imaging, excitation of these probes also remains elusive, which and its subsequent adoption for in vivo imaging of the limits imaging to wide-field modalities. One of the most nervous system [5], has spurred interest in such activity advanced probes of this class, VSFP2.3, was expressed in 2 reporters. A growing number of sensors are being devel- mouse somatosensory cortex; responses in 1 mm areas oped for many aspects of neural physiology, from mem- to single whisker deflection events were observed, but www.sciencedirect.com Current Opinion in Neurobiology 2011, 22:1–6 Please cite this article in press as: Looger LL, Griesbeck O. Genetically encoded neural activity indicators, Curr Opin Neurobiol (2011), doi:10.1016/j.conb.2011.10.024 CONEUR-1001; NO. OF PAGES 6 2 Neurotechnology single-trial signal was low (ratio change 0.25%; SNR mutants of these rhodopsins, potentially combined with 2–3) [15 ]. brighter retinal chromophore derivatives, may address the fundamental concern with this technology: the probes are Another GEVI variant is the hybrid ‘hVOS’ indicator [16], prohibitively dim in their current form. Improved ver- which transduces the voltage-dependent migration of sions of these indicators may finally facilitate systems dipicrylamine (DPA) through the membrane leaflet to level, cellular-resolution voltage imaging. ‘dark FRET’ with a membrane-targeted GFP. DPA is extremely toxic, however, and distribution in tissue is Calcium 2+ problematic. Given this, and the low SNR of the sensor, Action potential firing leads to Ca influx through voltage hVOS has not achieved much usage. gated calcium channels located throughout the cell [19]. 2+ Synaptic input directly gates Ca through neurotrans- A new class of GEVI is based instead on voltage-induced mitter-gated ion channels [20], primarily NMDA and fluorescence modulation of the retinal co-factor of bac- nicotinic receptors. Calcium is unique among ions in terial and archaeal rhodopsins. The first of these, PROPS terms of the magnitude of activity-induced changes 2+ [17 ], harnesses local pKa and pH modulation of the pore [21]. Quantification of free [Ca ] changes can thus be of a non-conducting proton pump (a mutant of green used as a reliable proxy for neural activity, in spine, proteorhodopsin) to control protonation, and resulting dendrite, axon, or soma. Calcium transients are signifi- fluorescence, of the retinal co-factor. Such voltage- cantly longer in duration than the voltage fluctuations that induced proton movements are extremely fast, and the give rise to them – this both integrates signal and funda- 2+ resulting sensors have submillisecond kinetics, sufficient mentally limits the temporal resolution with which Ca to resolve clear blinking events in individual Escherichia indicators may resolve neural activity. Small molecule 2+ coli bacteria [17 ]. An improved version of this sensor, Ca dyes have achieved widespread use in the last three VIP1, based on the archaerhodopsin-3 (Arch) proton decades, and state-of-the-art indicators like Oregon pump, robustly targets eukaryotic membranes and has Green BAPTA-1 (OGB-1) and fluo-4 have been the been used to image single action potentials and subthres- workhorses of in vivo functional imaging. These dyes hold depolarization in cultured neurons [18 ] (Figure 1a). are bright, photostable, high-affinity, and show very large 2+ A non-conducting Arch mutant, VIP2, had significantly Ca -dependent fluorescence changes. They are, how- slower kinetics but improved SNR. It is likely that further ever, limited to acute imaging experiments owing to Figure 1 (a) (b) Fluorescence 40 mV Voltage 100 ms (c) Current Opinion in Neurobiology Three new classes of genetically encoded sensors. (a) Archaerhodopsin-3 (Arch)-based voltage sensor. Left, rat hippocampal neuron expressing Arch (VIP1). Time-averaged fluorescence shown in cyan, voltage-responsive pixels shown in pink. Scale bar 50 mm. Right, recorded membrane potential (blue) and deconvolved fluorescence signal (red). Spiking induced by injection of 200 pA DC. Data are single-trial recording. Panel adapted from reference 18 courtesy of Adam Cohen. (b) New colors of GCaMP-based calcium indicators. 3-color fluorescence imaging of HeLa cells expressing nuclear red R-GECO1, cytoplasmic blue G-GECO1, and mitochondrial green B-GECO1. Figure adapted from reference 31 courtesy of Takeharu Nagai. (c) IntenseGluSnFr glutamate sensor displayed on the surface of cultured hippocampal neurons. Left, resting; middle, after a ‘puff’ of glutamate and AlexaFluor 568; right, after washout with buffer. Figure courtesy of Jonathan Marvin. Current Opinion in Neurobiology 2011, 22:1–6 www.sciencedirect.com Please cite this article in press as: Looger LL, Griesbeck O. Genetically encoded neural activity indicators, Curr Opin Neurobiol (2011), doi:10.1016/j.conb.2011.10.024 CONEUR-1001; NO. OF PAGES 6 Neural activity indicators Looger and Griesbeck 3 2+ clearance and accumulation in high-[Ca ] organelles. are the most widely

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us