Fv-08Vqc5 Fv-11Vqc5

Fv-08Vqc5 Fv-11Vqc5

FV-08VQC5 FV-11VQC5 6 8 Centered/ 9 11 11 11 12. Do not install with a method which is not approved in the instructions. These Panasonic ventilating fan models are equipped with a motion sensor and a humidity sensor that turn on automatically when motion is detected, when humidity increases rapidly, or when humidity rises above a 30% ~ 80% relative humidity set-point. It is user-adjustable to operate 0.5 ~ 60 minutes after the sensors are no longer detected. s a ) 8 9 ( 8 / 7 3 Motion sensor unit Humidity sensor unit 11 Fan body Junction box Main control circuit Red White White Neutral AC120V 60Hz Live (VENT.) Capacitor Black Black (Power supply) White White Motor Yellow Black Red (114 C Fuse in Motor) White lmpedance-protected Humidity sensor Black Black Green (Earth ground) Green Yellow Adjustment White Red switch Red White Motion sensor Humidity setting Timer Humidity Timer preset switch preset switch MA ~ X 80% % N I 0 3 M ~ MA X ~80% % N I 0 3 M ~ Humidity preset switch positions (Tolerance:±10%) MIN ~ MAX ~ 30% ~ 40% ~ 50% ~ 60% ~ 70% ~ 80% Factory setting: ~ 50% RH (" ~ " means "about") Timer preset switch positions Timer Position : refer to 0.5 minute Panasonic ventilating fan responds to: (1) Motion sensor detectible condition. (2) Humidity sensor detectible condition. Room temperature is Motion sensor detectible 25 (77 F). condition The delay time is determined by timer preset switch. Human activity The unit continues running for an adjustable duration Remains running of 0.5 to 60 minutes, after Fan activity Stop until the delay time motion is no longer detected. has passed Humidity sensor detectible condition (a) rapid to moderate humidity increases and (b) humidity above a 30% ~ 80% relative humidity set-point. (a) and (b) are set with "HUMIDITY SETTING" adjustment. Fan may occasionally turn on when environmental conditions change. The "TIMER" controls how long the fan remains on (a) after rise in humidity and (b) humidity level is below the set-point decreasing about 5%RH. 1. If this unit is to be install over a tub or shower, for best results, locate it near the shower head. 2. Long-time operation will influence the detecting precision as dust accumulates. Humidity preset switch may need to be adjusted. Motion sensor unit 6 Motion sensor unit page 4 7 fix (3 position) (Fig.6). 9. Adjust timer preset switch and humidity preset switch (Fig.7). Refer to switch indication on page 5. 8 CENTERED/ 9 4. Do not use cleaning sprays, solvents, or water on or near the sensors. Remove grille by pulling down the mounting spring opposite the sensor lead. 10 FV-08VQC5 15.5 815 FV-11VQC5 23.0 960 110 11 T0511-0 08VQC5420 .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    12 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us