TÜV RHEINLAND ENERGY GMBH Report on the performance test of the 48iQ ambi- ent air quality measuring system for carbon mon- oxide manufactured by Thermo Fisher Scientific TÜV Report 936/21242986/D Cologne, 4 February 2019 www.umwelt-tuv.de [email protected] TÜV Rheinland Energy GmbH and its Ambient Air Quality department in particular is accredited for the following activities: - Determination of emissions and ambient air quality affected by air pollutants and odorous substances, - Inspection of correct installation, functionality and calibration of continuous emission monitoring systems including systems for data evaluation and remote monitoring of emissions, - Measurements in combustion chambers; - Performance testing of measuring systems for continuous monitoring of emissions and air quality as well as electronic data evaluation and remote monitoring systems for emissions - Determination of the stack height and air quality forecasts for hazardous and odorous substances; - Determination of emissions and ambient air quality affected by noise and vibration, determination of - sound power levels and noise measurements at wind turbines; according to EN ISO/IEC 17025. The accreditation will expire on 10-12-2022 and covers the scope specified in the annex to certificate D-PL-11120-02-00. Reproduction of extracts from this test report is subject to prior written consent. TÜV Rheinland Energy GmbH D - 51105 Köln, Am Grauen Stein, Tel: + 49 (0) 221 806-5200. fax: +49 (0) 221 806-1349 740300_2019_936_21242986D_EN.docx TÜV Rheinland Energy GmbH Air Pollution Control Report on the performance test of the 48iQ ambient air quality measuring Page 2 of 369 system for carbon monoxide manufactured by Thermo Fisher Scientific, Report No.: 936/21242986/D Blank page 740300_2019_936_21242986D_EN.docx TÜV Rheinland Energy GmbH Air Pollution Control Report on the performance test of the 48iQ ambient air quality measuring sys- tem for carbon monoxide manufactured by Thermo Fisher Scientific, Page 3 of 369 Report No.: 936/21242986/D Report on the performance test of the 48iQ ambient air quality measuring system for carbon monoxide manufactured by Ther- mo Fisher Scientific AMS designation: 48iQ Manufacturer: Thermo Fisher Scientific 27, Forge Parkway Franklin, MA 02038 USA Test period: April 2018 to October 2018 Date of report: 4 February 2019 Report Number: 936/21242986/D Editor: Dipl.-Ing. Martin Schneider Phone: +49 221 806-1614 [email protected] Scope of the report: Report: 119 pages Manual 119 Manual 261 pages Total 369 pages 740300_2019_936_21242986D_EN.docx TÜV Rheinland Energy GmbH Air Pollution Control Report on the performance test of the 48iQ ambient air quality measuring Page 4 of 369 system for carbon monoxide manufactured by Thermo Fisher Scientific, Report No.: 936/21242986/D Blank page 740300_2019_936_21242986D_EN.docx TÜV Rheinland Energy GmbH Air Pollution Control Report on the performance test of the 48iQ ambient air quality measuring sys- tem for carbon monoxide manufactured by Thermo Fisher Scientific, Page 5 of 369 Report No.: 936/21242986/D Table of contents 1. SUMMARY AND CERTIFICATION PROPOSAL ...........................................................12 1.1 Summary Overview ........................................................................................................12 1.2 Certification proposal ......................................................................................................13 1.3 Summary report on test results .......................................................................................14 2. TASK DEFINITION ........................................................................................................20 2.1 Nature of the test ............................................................................................................20 2.2 Objectives ......................................................................................................................20 3. DESCRIPTION OF THE AMS TESTED ........................................................................21 3.1 Measuring principle ........................................................................................................21 3.2 AMS scope and set-up ...................................................................................................23 3.3 AMS adjustment .............................................................................................................25 4. TEST PROGRAMME ....................................................................................................26 4.1 General remarks .............................................................................................................26 4.2 Laboratory test ...............................................................................................................27 4.3 Field test .........................................................................................................................27 5. REFERENCE MEASUREMENT METHOD ...................................................................28 5.1 Method of measurement .................................................................................................28 6. TEST RESULTS IN ACCORDANCE WITH VDI 4202, PART 1 (2018) ..........................29 6.1 7.3 General requirements .........................................................................................29 6.1 7.3.1 Measured value display ...................................................................................29 6.1 7.3.2 Calibration inlet ................................................................................................30 6.1 7.3.3 Easy maintenance ...........................................................................................31 6.1 7.3.4 Functional check ..............................................................................................32 6.1 7.3.5 Set-up times and warm-up times ......................................................................33 740300_2019_936_21242986D_EN.docx TÜV Rheinland Energy GmbH Air Pollution Control Report on the performance test of the 48iQ ambient air quality measuring Page 6 of 369 system for carbon monoxide manufactured by Thermo Fisher Scientific, Report No.: 936/21242986/D 6.1 7.3.6 Instrument design ............................................................................................34 6.1 7.3.7 Unintended adjustment ....................................................................................35 6.1 7.3.8 Data output ......................................................................................................36 6.1 7.3.9 Digital interface ................................................................................................37 6.1 7.3.10 Data transmission protocol .............................................................................38 6.1 7.3.11 Measuring range ............................................................................................39 6.1 7.3.12 Negative output signals ..................................................................................40 6.1 7.3.13 Failure in the mains voltage ...........................................................................41 6.1 7.3.14 Operating states .............................................................................................42 6.1 7.3.15 Switch-over ....................................................................................................43 6.1 7.3.16 Instrument software........................................................................................44 6.1 7.4 Requirements on performance characteristics in the laboratory ..........................45 6.1 7.4.1 General requirements ......................................................................................45 6.1 7.4.2 Test requirements ............................................................................................46 6.1 7.4.3 Response time and memory effect ...................................................................48 6.1 7.4.4 Short-term drift .................................................................................................49 6.1 7.4.5 Repeatability standard deviation ......................................................................50 6.1 7.4.6 Linearity ...........................................................................................................51 6.1 7.4.7 Sensitivity coefficient to sample gas pressure ..................................................52 6.1 7.4.8 Sensitivity coefficient to sample gas temperature .............................................53 6.1 7.4.9 Sensitivity coefficient to surrounding temperature ............................................54 6.1 7.4.10 Sensitivity coefficient to electrical voltage .......................................................55 6.1 7.4.11 Cross sensitivity .............................................................................................56 6.1 7.4.12 Averaging effect .............................................................................................57 6.1 7.4.13 Difference between sample and calibration port .............................................58 6.1 7.4.14 Converter efficiency .......................................................................................59 740300_2019_936_21242986D_EN.docx TÜV Rheinland Energy GmbH Air Pollution Control Report on the performance test of the 48iQ ambient air quality measuring sys- tem for carbon

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    406 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us