Diagnostics for LM Characterization (Tsai)

Diagnostics for LM Characterization (Tsai)

Diagnostics for liquid metal (LM) characterization C. C Tsai, S. W. Allison, M. R. Cates, E. T. Manneschmidt, M. M. Menon, and B. Nelson Oak Ridge National Laboratory, Oak Ridge, TN 37831 Diagnostics are needed for liquid flow experiments for Chamber Technology Research Area. • Develop techniques to measure flow characteristics. – Flow velocity. – Flow thickness. – Flow instabilities. • Measure the thermal response of LM under high heat flux conditions. – Temperature profiles. – Temperature equilibration time after high heat flux pulse loads. • Estimating pumping characteristics of liquid is important prior to introducing LM test modules in major fusion experiments such as NSTX. – Pumping of room temperature hydrogen/deuterium gas – Pumping of energetic hydrogen particles Two novel diagnostics will be developed for LM characterization. • A frequency modulated (FM) coherent laser radar (CLR), utilizing Doppler effect, will be utilized for non-intrusive measurement of LM flow characteristics. – Flow velocity – Flow film thickness – Flow instabilities • Fluorescent phosphor thermometry for measurement of LM temperature – Temperature profile – Temperature equilibration times under high heat flux loading. The FM CLR would be very useful for LM flow characterization • Truly remote measurements using Doppler effect: – Flow velocity distribution – Film thickness distribution Window – Flow instabilities (slow time scale) V • v = f. CLR Laser beam Where, v is the velocity component of Flowing liquid surface the flow in the beam direction, and is the laser wavelength, and fis the Doppler shift in frequency. • By increasing the angle of incidence of the laser beam, the measurable velocity range can be extended. Fluorescent phosphor thermometry can be used for non- contact measurements of LM surface temperature • The technique involves dusting LM surface with special phosphor powder, exciting the phosphor with UV laser, and measuring the fluorescence characteristics using a photomultiplier tube. • The florescence decay characteristic is a measure of the temperature. • The technique can be used to measure surface temperature distribution as well as thermal equilibration time after pulsed heat input. Phosphor Thermometry for Liquid Gallium Drop Fluorescence decay characteristics of a phosphor in liquid gallium surface at two different temperatures • The response is very fast (~ 10µs) • Temperature resolution of few degrees is attainable Fluorescence decay characteristics of a phosphor in liquid gallium surface at different temperatures Preliminary Results Of Phosphor Thermometry Are Encouraging • We have done preliminary compatibility tests of phosphor on liquid Ga and liquid Li • We are preparing to do additional PT tests on static Li. • PT tests on a circulating liquid metal or conducting liquid will be pursued this year. • The design and fabrication of a LM module with an EM pumping will be initiated this year. Summary • Two diagnostics are proposed for liquid wall research – FM coherent laser rada – Phosphor Thermometry • Tests are planned to develop these methods: – Temperature tests on static liquid – Temperature and flow characteristic tests on moving liquid.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    10 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us