ELECTRONIC GOVERNOR LOW PROFILE GASOLINE GENERATORS ADJUSTMENT /CALIBRATION and COMPONENT TROUBL HOOTING GUIDE ~-·~:·

ELECTRONIC GOVERNOR LOW PROFILE GASOLINE GENERATORS ADJUSTMENT /CALIBRATION and COMPONENT TROUBL HOOTING GUIDE ~-·~:·

~ ............... 'c,}'"················ '•• •.. · .. l_-./ ~··•\. ELECTRONIC GOVERNOR LOW PROFILE GASOLINE GENERATORS ADJUSTMENT /CALIBRATION and COMPONENT TROUBL HOOTING GUIDE ~-·~:·--- ·.I.r 4th EDITION AUGUST2016 ~r~ •WESTERBEKE j WESTERBEKE CORPORATION • 150 JOHN HANCOCK ROAD j MYLES STANDISH INDUSTRIAL PARK • TAUNTON MA 02780 ..,WEBSITE:__ _ WWW. WESTERBEKE.COM ..,,...,.,NMMA Member National Marine Manufacturers Association GOVERNOR SYSTEM COMPONENTS and OPERATION DESCRIPTION MAGNETIC PICK·UP [MPUJ INSTALLATION The Electronic Governor consists of three components, the The MPU is installed· in the threaded opening on the side CONTROLLER, a pc board installed in the control panel. A of the flywheel bellhousing. This positions the MPU over MAGNETIC PICK-UP (MPU) installed in the bellhousing over the teeth of the flywheel ring gear. the engine flywheel and the linear ACTUATOR mounted on the Viewing through this opening, manually rotate the engine engine and attached by linkage to the injection pump crankshaft so as to position the flat of one of the ring throttle control. · gear's teeth directly under the opening. Thread the MPU into the opening until it gently contacts the flat of this SYSTEM OPERATION tooth (Thread is 3/8" x 24). Back the MPU out of the On start up system DC voltage is supplied to the controller to opening one tum and then lock it in this position with the use for actuator operation. When the starter is energized and jam nut. This will position the end of the MPU the engine cranks, the magnetic pick-up (MPU) that is approximately 0.030 inches away from the flats of the ring positioned over the engines flywheel ring gear sends a low gear teeth. AC signal to the controller (1.5 - 2.5 AC volts). To ensure the MPU is positioned correctly, slowly rotate The controller interprets this as engine cranking speed and the crankshaft by 360° by hand to assure there is no sends a DC voltage to the actuator to operate the carburetor's physical contact between the MPU and the ring gear teeth. throttle ann. The position of the throttle by the actuator has If contact is felt between the MPU and the flywheel teeth, been previously determined by the speed adjustment on the the MPU may be damaged. Remove the MPU and inspect speed controller. The engine carries up to a set speed it. Replace if necessary and repeat the above determined by the AC voltage sent by the MPU. installation procedure. The speed controller maintains this signal no load to full load by varying the DC voltage to the actuator providing more or less throttle depending on the generator load. Gain Adjustment The gain can be adjusted using a small screwdriver. Adjustment should be between 30% and 40% as is required / to dampen speed oscillation under load. An adjustment of more than 40% can cause the unit to race (speed up) when //~ ,{/ ---- the load is removed or go into a hunting mode. / BACK PLATE 50 NOTE: If replacing the Magnetic Pick-Up (MPU) it MUST \ I I be replaced without cutting and splicing into the existing 'CS); wiring cable. Doing so will cause a erratic' AC signal to -, ....- GAIN ADJUSTMENT the controller. I \ 0 '\00 GOVERNOR CIRCUIT VOLTAGES Monitoring the voltages found in the electronic governor's Speed Controller circuit will be helpful in determining where in the circuit The speed controller has a green LED indicating power to the operating fault lies and with which component. the controller, a plus and minus speed adjustment (buttons) The circuit voltages listed with the circuit "wiring and a gain adjustment. The green LED blinks when the schematic" are the approximate voltages found in the power is turned on and after it receives a signal from the governor circuit with the unit running at idle and at magnetic pick-up, it blinks at a faster rate. normal 1800rpm. The electronic governor's circuit voltages can all be read and monitored from the connections on the 12 position GAIN terminal strip as illustrated. 2 ELECTRONIC SPEED ~ CONTROUER Engines & Generators 1 PANEL COMPONENT.S/WIRING OVERSPEED PC BOARD ELECTRONIC SPEED PN: 056075 • 60/50 Hz CONTROLLER PN 046945 ~NOTE: For wiring connection NOTE: For wiring connection::::-. to the diagram below. refer to the diagram SPEED ACTUATOR MAGNETIC PICK·UP PN 046490 (MPU) PN 046874 3.0 ·3.2 OHM 950 • 1000 OHM MAGNETIC PICK-UP (MPU) PN 046874 950 ·1 ODD OHM WIRING SCHEMATIC NOMINAL VOLTAGES at IDLE and 1800 RPM OVERSPEED PC . IDLE ( 700-800 rpm ) BOARD PN 046490 (Use DEC button on Controller .TERMINALS ~----I1 l I to lower engine rpm.) #7-+ #6 1.5-2.5 VAC #9 •+ #8 5.0-5.5 DC Irf?JI (illl®J~ffffiUi+ " -· '/ '- #10-+ #11 6.5 -7.0 0~ ' 9 8 #16-+ #16 12.2 DC · RED BLACK VOLTAGES #16 BLACKIWHI~ SHOWN ARE #16 WHITE 1800 RPM TYPICAL ONIC SPEED ELECTR 116 VIOLET/WHITE(+) CONTRO . TERMINALS r... ,..... #16 VIOLET(-) \ #7-+ #6 4 ·7 AC NOTE:~£ WIRE ARE #9-+ #8 5.5-6.5 DC POLARITY SENSAT/V£ 116 BLACK (DC·) . OBSERVE WIRE TERM/ 11/AL #10-+ #11 6.0-6.5 DC· ~ I NUMBERS ;:, l;g. #16-+ #16 13.1 DC RED BLACK ~ I HOURMETER NOTE: SPEED IS ADJUSTED USING iNC/DEC PODS Engines & Generators ON THE CONTROLLER 2 CARBURETOR • LOW PROFILE CARBURETOR ADJUSTMENT: THE IDLE MIXTURE CAN BE The carburetor is a single barrel, side-draft type with a ADJUSTED BY PRYING OFF THE PLASTIC CAP. cleanable metal screen air intake filter/spark arrester. TURN THE SCREW ALL THE WAY DOWN- THEN BACK THE SCREW OUT 3 1/2 TURNS. ONCE Air Screen RUNNING, ADJUST NO MORE THAN 1/2 TURN IN The air screen can easily be removed. Clean after the first 50 EITHER DIRECTION WHEN STABILIZING THE ENGINE hours of operation and every 100 hours from then on. Clean SPEED. the air screen in a water soluble cleaner such as GUNK. CHOKE SOLENOID The choke solenoid is a 12 volt DC operated unit that func­ tions to close the choke plate in the carburetor when the ON switch is depressed during engine start-up. SPARK ARRESTER SILENCER ON SWITCH {CHOKE ENERGIZED] The choke solenoid de-energizes once the engine starts and the ON switch is released. Some unstable running may be present when the engine starts cold but should smooth out as the engine reaches operating temperature. NOTE: THE CHOKE MECHANISM SHOULD FLUTTER WHEN THE ENGINE IS CRANKING. THE RETURN Confirm Proper Operation SPRING MUST REST AGAINST THE ACTUATORS Start the engine and allow the engine to warm up. Once MOUNTING BRACKET- NOT IN THE HOLE IN THE CASTING BOSS. warm, engage the ON switch. If the engine chokes and stops, SPEED ACTUATOR: the choke linkage needs to be lengthened to hold the choke THE SPEED ACTUATOR open slightly more. If the engine slows but continues to run, SHOULD MOVE FREELY. the adjustment is ok. KEEP THE SOLENOID DRY AND LUBRICATE THE LINKAGE WITH TEFLON Linkage Adjustment OR GRAPHITE LUBRICANT Adjust the linkage so that when the choke solenoid is ONLY. energized, the choke butterfly/ .lever is open approximately 1116". Adjust the linkage so the pin hole in the linkage is approximately 1116" beyond the fully closed choke lever.. then connect the choke lever to the linkage. Refer to the IDLE MEASURE ADJUSTMENT at the top of this page. e Speed Actuator Adjustment sumRFLvli.EVEi (}) -· The speed actuator ad jus. tment should be the only device in OPEN 1116 .~"!-- control of the throttle's position. The throttle linkage's eye II !===== bolts must be 2 5/8" apart (see illustration. The throttle · should be in full fuel position when the unit is shutdown. Engines & Generators 3 BATTERY CHARGE CONTROLLER THE CHARGING SYSTEM Testing the Battery Charger (PN:03B469J Westerbeke's low profile generators are equipped with a To test the battery charger, put a multimeter between the battery charge controller that is powered from a separate positive(+) and negative(-) leads to the battery. It should winding in the generator. The battery charger controller is an indicate 13.0V to 13.1 V with the engine running. If only the encapsulated, solid-state unit that supplies a DC charging battery voltage is indicated, check that the battery charger voltage to the generator's starting battery while the generator terminal connections are tight. With the unit running, test is operating. between the (+) and (-) on the battery charger ( as illustrated) Charging Voltage: 13.0 • 13.1 Volts DC for 13.0V to 13.lV: If no charge is indicated, replace the Charging Amperage: 0 • 12 Amps DC charger. '. NOTE: The battery charging circuit is totally separate from Use of a dedicated and isolated starting battery is strongly recommended. the AC output of the generator. The generator output affects the circuits output, but not the reverse. FUSE • INTEGRAL CONTROLLER WINDING: NO TIME DELAY------__, A separate group of stator windings supplies AC voltage to a Pn#43634 30A bridge rectifier which converts the AC current to supply the 250V MDA-30 . BRIDGE charging unit. The unit senses the needs of the starting battery and supplies a DC charge when one is needed. If you suspect that the unit is faulty (if the battery's charge is low), check the charging circuit and it's components(see TESTING (·) THE BATTERY CHARGER). Check all connections for cleanliness and tightness including the ground before 50Hz replacing the I.C. charger. NOTE: When the generator is first started, the charger will produce a low charging rate. This charging rate will rise as the generator is operated. Fuse Protection There are two 30 amp fuses protecting the DC charge circuit. One 30 amp buss fuse mounted on the control panel box and a spade type automotive 30 amp fuse in a holder adjacent to the starter motor.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    9 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us