Solicitation AMD 003 E Final

Solicitation AMD 003 E Final

1 1 RETURN BIDS TO: Title - Sujet RETOURNER LES SOUMISSIONS À: LaSalle Causeway Bridge Engineering Bid Receiving - PWGSC / Réception des soumissions Solicitation No. - N° de l'invitation Date TPSGC EQ754-201337/A 2019-12-10 10th Floor, 4900 Yonge Street / Client Reference No. - N° de référence du client Amendment No. - N° modif. 10e étage, 4900 rue Yonge EQ754-201337 003 Toronto Ontario File No. - N° de dossier CCC No./N° CCC - FMS No./N° VME M2N 6A6 PWL-9-42060 (034) GETS Reference No. - N° de référence de SEAG PW-$PWL-034-2496 Date of Original Request for Standing Offer 2019-10-21 Revision to a Request for a Standing Offer Date de la demande de l'offre à commandes originale Révision à une demande d'offre à commandes Solicitation Closes - L'invitation prend fin Time Zone Fuseau horaire Departmental Individual Standing Offer (DISO) at - à 02:00 PM on - le 2020-01-07 Eastern Standard Offre à commandes individuelle du département(OCID) Time EST Address Enquiries to: - Adresser toutes questions à: Buyer Id - Id de l'acheteur Somaratna, Chinthaka pwl034 The referenced document is hereby revised; unless otherwise indicated, all other terms and conditions of Telephone No. - N° de téléphone FAX No. - N° de FAX the Offer remain the same. (416) 305-7369 ( ) (416) 952-1257 Delivery Required - Livraison exigée Ce document est par la présente révisé; sauf indication contraire, les modalités de l'offre demeurent les mêmes. Destination - of Goods, Services, and Construction: Destination - des biens, services et construction: Comments - Commentaires Lasalle Causeway Lift Bridge THIS DOCUMENT CONTAINS A SECURITY Kingston, ON REQUIREMENT. Vendor/Firm Name and Address Security - Sécurité Raison sociale et adresse du This revision does not change the security requirements of the Offer. fournisseur/de l'entrepreneur Cette révision ne change pas les besoins en matière de sécurité de la présente offre. Instructions: See Herein Instructions: Voir aux présentes Acknowledgement copy requiredYes - Oui No - Non Accusé de réception requis Issuing Office - Bureau de distribution Public Works and Government Services Canada The Offeror hereby acknowledges this revision to its Offer. Ontario Region Le proposant constate, par la présente, cette révision à son offre. 10th Floor, 4900 Yonge Street Toronto Ontario Signature Date M2N 6A6 Name and title of person authorized to sign on behalf of offeror. (type or print) Nom et titre de la personne autorisée à signer au nom du proposant. (taper ou écrire en caractères d'imprimerie) For the Minister - Pour le Ministre Page 1 of - de 1 N° de l’invitation - Solicitation No. N° de la modif - Amd. No. Id de l’acheteur - Buyer ID EQ754-201337/A 003 pwl034 N° de réf. du client - Client Ref. No. File No. - N° du dossier N° CCC / CCC No./ N° VME - FMS EQ754-201337 PWL-9-42060 Amendment No. 003 This amendment is being raised to 1) incorporate revisions to the following sections of the Request for a Standing Offer: Submission Requirements and Evaluation (SRE) 3, 3.2 Rated Requirements, a) 3.2.4 Senior Personnel Expertise and Experience, and b) 3.2.6 Hypothetical Projects and 2) provide responses to Requests for Clarification. 1) Revisions to the Request for a Standing Offer a) Reference: Submission Requirements and Evaluation (SRE) 3, 3.2 Rated Requirements, 3.2.4 Senior Personnel Expertise and Experience, article 2.II.b. Proponents are instructed to: Delete: Short pertinent examples of at least 3 projects/inspection/evaluations on bridges that are pertinent to the range of services listed in the Required Services (RS) section. Eligible projects should have received substantial certificate of completion within the past five (5) years. Proponents will receive a lower score if examples are for projects that have no comparison in scope and scale to the type of project to be delivered under this Standing Offer, or are not related to the range of services listed in the Required Services; and Insert: Short pertinent examples of at least 3 projects/inspection/evaluations on bridges that are pertinent to the range of services listed in the Required Services (RS) section. Eligible projects should have received substantial certificate of completion within the past ten (10) years. Proponents will receive a lower score if examples are for projects that have no comparison in scope and scale to the type of project to be delivered under this Standing Offer, or are not related to the range of services listed in the Required Services; and b) Reference: Submission Requirements and Evaluation (SRE) 3, 3.2 Rated Requirements, 3.2.6 Hypothetical Projects i) Project 1 – Design and Supervision of a Bridge Rehabilitation Project Proponents are instructed to: Delete: Project 1 – Design and Supervision of a Bridge Rehabilitation Project: a) Scenario: PWGSC is planning a rehabilitation project of the Alexandra Bridge superstructure steel. The Alexandra Bridge is a steel truss cantilever bridge that was constructed from 1898 to 1901 and is an interprovincial crossing that connects the cities of Ottawa, Ontario and Gatineau, Quebec, lying on either side of the Ottawa River. The bridge carries 18,000 vehicles per day composed of a mix of some trucks, but mainly buses and light vehicles. The total length of bridge is 575 m and the bridge was rehabilitated at several occasions since it was put in service in 1901. The Alexandra Bridge was painted entirely in 1995-96 and it has been observed over time that corrosion and deterioration does not progress at the same rate on the different parts of the structure because of the difference in environmental exposure conditions of the bridge components. Areas located below the travelled deck are prone to more exposure to road salt de-icing and debris accumulation. Therefore, the corrosion and deterioration rates progress more quickly below the deck than above the deck. Some parts of the Page 1 of – de 10 N° de l’invitation - Solicitation No. N° de la modif - Amd. No. Id de l’acheteur - Buyer ID EQ754-201337/A 003 pwl034 N° de réf. du client - Client Ref. No. File No. - N° du dossier N° CCC / CCC No./ N° VME - FMS EQ754-201337 PWL-9-42060 trusses upper structure are still quasi-intact from the 1995-96 paint project, while some parts of the structure below the deck now show important needs of steel replacement due to deterioration. In recent inspection reports, consultants have recommended that PSPC proceed with steel replacement with paint protection to re-establish the steel capacity of those components where deterioration has been identified. A major rehabilitation was completed from 2009 to 2010 which included the following: replacement of the center lane concrete deck including guardrails, strengthening of the truss structure, retrofitting of the superstructure and substructure to live load and seismic capacity, addition of tuned mass dampers, addition of catwalks, replacement of the pedestrians wooden boardwalk and its railings and partial retrofit to the lighting system. The various components of a bridge all have different rates of wear and tear. During the establishment of the scope of work of this 2009-10 major rehabilitation, overall painting of the structure was excluded because PSPC wanted to evaluate the exiting painting system and take on a recommended approach of zone coating as opposed to an overall painting. In 2013-14, the 118 m long north Gatineau Trestle area was strengthened and fully painted through a zone painting contract. The area of Pier 3 along with other specific locations were partially strengthened as part of a contract completed in 2016-17. The present project will concentrate on replacement, strengthening, and coating of steel components in the area of Pier 2, other specific components throughout the bridge and the components removed from the 2016-17 contract. Traffic interruptions on the bridge, on the loading dock of the museum, and on the bicycle/pedestrian path must be kept to a minimum during the contract. Access to the Alexandra Bridge needs to be coordinated with NCC, the city of Gatineau (marina operator), the Museum of History and PSPC. For this steel replacement contract, the scaffolding, enclosure and environmental protection system will need to be erected around and supported by the bridge structure. The area of work is over the Ottawa River. The goal of the present contract is to keep the structure in a safe state of service with a target start date of construction assumed to be Fall of 2021. b) Engineering Services Required — The services required would fall into RS 2.1 Pre- Design Services through to RS 2.7 Post Construction Warranty Review. 1. Your firm has been requested to prepare design for the: (1) Steel replacement to be completed for the steel structure below the roadway deck in the Pier 2 area from floor beam 5 to 14, as well as steel replacement from the tops of pier 2 to the height of the top HSS rail of the center lane deck parapet wall; (2) Within this zone of work, selected components of the steel structure will need to be identified and evaluated for deteriorations and will need to be replaced or strengthened due to loss of section, perforations, cracks and others; (3) Steel replacement or strengthening to specific locations of the structure; and (4) Prepare and administer a zone painting contract for the existing steel within the area of Pier 2. 2. Provide a description of the studies required to complete rehabilitation to satisfy requirements of the CHBDC. c) Take into consideration phasing of project for Health and Safety reasons (time and space separation) in order to minimize traffic interruptions on the bridge, on the loading dock of the museum, and on the bicycle/pedestrian path. d) In addition, provide an analysis of issues, and list studies that would be required prior to proceeding with design development work.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    11 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us