UFGS 07 12 00 Built-Up Bituminous Waterproofing

UFGS 07 12 00 Built-Up Bituminous Waterproofing

************************************************************************** USACE / NAVFAC / AFCEC / NASA UFGS-07 12 00 (February 2016) ------------------------------------ Preparing Activity: NAVFAC Superseding UFGS-07 12 00 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated July 2021 ************************************************************************** SECTION TABLE OF CONTENTS DIVISION 07 - THERMAL AND MOISTURE PROTECTION SECTION 07 12 00 BUILT-UP BITUMINOUS WATERPROOFING 02/16 PART 1 GENERAL 1.1 REFERENCES 1.2 SUBMITTALS 1.3 MANUFACTURER'S DETAIL 1.4 ENVIRONMENTAL CONDITIONS 1.5 DELIVERY AND STORAGE 1.5.1 Materials Packaging 1.5.2 Materials Storage 1.5.2.1 Asphalt 1.5.2.2 Reinforcement Fabrics 1.5.3 Bulk Liquid Asphalt 1.5.3.1 Asphalt Shipment Records 1.6 Flame Heated Equipment 1.6.1 Fire Protection 1.6.2 Operational Requirements 1.6.3 Drippage of Bitumen PART 2 PRODUCTS 2.1 PRODUCT SUSTAINABILITY CRITERIA 2.1.1 Reduce Volatile Organic Compounds (VOC) Contents 2.1.2 Recycled Content 2.2 BITUMEN 2.3 BITUMINOUS PLASTIC CEMENT 2.4 MEMBRANE FABRIC 2.4.1 Cotton Fabrics 2.4.2 Woven Burlap Fabrics 2.5 NAILS 2.6 PRIMER 2.7 PROTECTION BOARD 2.8 PREFABRICATED LAMINATED ASPHALT WATERPROOFING 2.9 PREFABRICATED COPPER FABRIC SHOWER PANS 2.10 WOOD NAILERS SECTION 07 12 00 Page 1 PART 3 EXECUTION 3.1 INSPECTION OF SURFACES 3.2 PREPARATION OF SURFACES 3.3 APPLICATION 3.3.1 Building Envelope Requirements 3.3.2 General Installation Requirements 3.3.3 Prefabricated Pan 3.3.4 Protection of Surrounding Areas 3.3.5 Heating and Application of Bitumen Coatings 3.3.6 Membrane Waterproofing 3.3.6.1 Below Grade Wall Waterproofing 3.3.6.2 Floor Waterproofing 3.3.7 Fabric Membrane Reinforcement 3.3.8 Keyed Joint Footings 3.3.9 Flashing Flanges 3.3.10 Clamping Devices 3.3.11 Reglets 3.4 FIELD TEST 3.4.1 Sampling and Testing of Bulk Liquid Asphalt 3.4.2 Test of Membrane Waterproofing 3.5 PROTECTIVE COVERING 3.5.1 Vertical Surfaces 3.5.2 Horizontal Surfaces 3.6 CLEAN UP 3.7 SCHEDULE OF MATERIALS -- End of Section Table of Contents -- SECTION 07 12 00 Page 2 ************************************************************************** USACE / NAVFAC / AFCEC / NASA UFGS-07 12 00 (February 2016) ------------------------------------ Preparing Activity: NAVFAC Superseding UFGS-07 12 00 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated July 2021 ************************************************************************** SECTION 07 12 00 BUILT-UP BITUMINOUS WATERPROOFING 02/16 ************************************************************************** NOTE: This guide specification covers the requirements for built-up bituminous membrane waterproofing. Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable item(s) or insert appropriate information. Remove information and requirements not required in respective project, whether or not brackets are present. Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR). ************************************************************************** ************************************************************************** NOTE: This specification is intended for use where local practice and experience indicates, or where International Code Council (ICC), International Building Code (IBC), section Dampproofing and Waterproofing allows, that protection against hydrostatic pressure or conditions of excessive dampness can be achieved by using membrane waterproofing. For other acceptable methods of waterproofing, refer to the appropriate unified facilities guide specification. NOTE: Verify compliance of the project with ICC IBC section Dampproofing and Waterproofing, particularly article 1805.3 which says "Where the ground water investigation required by Section 1803.5.4 indicates that if a hydrostatic pressure condition exists, and SECTION 07 12 00 Page 3 the design does not include a ground water control system as described in Section 1805.1.3, walls and floors must be waterproofed in accordance with this section". If the project is not compliant with this requirement, do not use this specification section; choose appropriate resilient membrane waterproofing system instead. ************************************************************************** PART 1 GENERAL 1.1 REFERENCES ************************************************************************** NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title. Use the Reference Wizard's Check Reference feature when you add a Reference Identifier (RID) outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates. References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process. ************************************************************************** The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM C208 (2012; R 2017; E 2017; E 2019) Standard Specification for Cellulosic Fiber Insulating Board ASTM C726 (2017) Standard Specification for Mineral Wool Roof Insulation Board ASTM D41/D41M (2011; R 2016) Standard Specification for Asphalt Primer Used in Roofing, Dampproofing, and Waterproofing ASTM D173/D173M (2003; R 2011; E 2012) Bitumen-Saturated Cotton Fabrics Used in Roofing and Waterproofing ASTM D226/D226M (2017) Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing SECTION 07 12 00 Page 4 ASTM D449/D449M (2003; R 2014; E 2014) Asphalt Used in Dampproofing and Waterproofing ASTM D517 (1998; R 2008) Asphalt Plank ASTM D1327/D1327M (2004; R 2020) Standard Specification for Bitumen-Saturated Woven Burlap Fabrics Used in Roofing and Waterproofing ASTM D1668/D1668M (1997a; R 2014; E 2014) Glass Fabrics (Woven and Treated) for Roofing and Waterproofing ASTM D2178/D2178M (2015a) Asphalt Glass Felt Used in Roofing and Waterproofing ASTM D4586/D4586M (2007; E 2012; R 2012) Asphalt Roof Cement, Asbestos-Free 1.2 SUBMITTALS ************************************************************************** NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list, and corresponding submittal items in the text, to reflect only the submittals required for the project. The Guide Specification technical editors have classified those items that require Government approval, due to their complexity or criticality, with a "G." Generally, other submittal items can be reviewed by the Contractor's Quality Control System. Only add a "G" to an item if the submittal is sufficiently important or complex in context of the project. For Army projects, fill in the empty brackets following the "G" classification, with a code of up to three characters to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: "AE" for Architect-Engineer; "DO" for District Office (Engineering Division or other organization in the District Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project Office. Codes following the "G" typically are not used for Navy, Air Force, and NASA projects. The "S" classification indicates submittals required as proof of compliance for sustainability Guiding Principles Validation or Third Party Certification and as described in Section 01 33 00 SUBMITTAL PROCEDURES. Choose the first bracketed item for Navy, Air Force, and NASA projects, or choose the second bracketed item for Army projects. ************************************************************************** Government approval is required for submittals with a "G" or "S" SECTION 07 12 00 Page 5 classification. Submittals not having a "G" or "S" classification are [for Contractor Quality Control approval.][for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.] Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data ************************************************************************** NOTE: Prefabricated laminated asphalt membrane waterproofing and copper fabric shower pans may be included as a Contractor's option for shower pans. ************************************************************************** Manufacturer's Standard Details, G[, [_____]] Protection Board; G[, [_____]] [ Prefabricated Laminated Asphalt Waterproofing; G[, [_____]] ][ Prefabricated Copper Fabric; G[, [_____]] ] Membrane Fabric; G[, [_____]] Reinforcing Fabric; G[, [_____]] SD-06 Test Reports ************************************************************************** NOTE: Bulk liquid asphalt may be included as a Contractor's option when the project is constructed

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    17 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us