Analysis of 2,4-DNPH-Derivatized Aldehydes

Analysis of 2,4-DNPH-Derivatized Aldehydes

Hitachi High Performance Liquid Chromatograph Analysis of 2,4-DNPH-Derivatized Aldehydes Sick house syndrome, a syndrome in which air polluted by chemical substances dissipated from house building materials, interiors, etc., causes human health problems, has become an issue. Accordingly, in Japan the measurement of chemical substances such as formaldehyde and volatile organic compounds (VOC) became mandatory in 2002 and 2003, as directed by the Ministry of Education, Culture, Sports, Science and Technology, the Ministry of Land, Infrastructure, Transport and Tourism, and the Ministry of Health, Labor and Welfare. In addition, starting from March 1, 2009, working environment concentration controls were established for the production and all handling work of formaldehyde. Since aldehydes are not detected in a highly sensitive manner by UV detection methods, HPLC is utilized to measure solvent extracted samples of aldehydes from ambient air collected in trap tubes and derivatized*1 with 2,4-dinitrophenylhydrazine (DNPH). The following describes examples of analysis of 2,4-DNPH derivatized aldehydes. Analysis of 2,4-DNPH-Derivatized Aldehydes *1 Samples: DNPH derivatized aldehydes Example of 2.4-DNPH derivatization Aldehyde is derivatized by suctioning ambient air into trap tubes <Standard samples> filled with 2,4-DNPH-impregnated silica gel. Injection samples 1.Formaldehyde-DNPH are prepared by eluting the DNPH-aldehyde with acetonitrile. 2.Acetaldehyde-DNPH 3.Acetone-DNPH Atmosphere Ozone scrubber trap tube Pump Gas meter 4.Propionaldehyde-DNPH 5.Crotonaldehyde-DNPH 6.Isobutylaldehyde-DNPH 7.Benzaldehyde-DNPH 8.N-valeraldehyde-DNPH Used after preparation with acetonitrile and dilution as required Figure 1. Collection method for aldehyde in ambient air Analysis results of standard samples 5.00 [LC Conditions] 1. Formaldehyde (HCHO); concentration: 0.07 mg/L, 4.50 ( ) HITACHI Lachrom C18 (5 µm) 2. Acetoaldehyde CH3CHO ; concentration: 0.1 mg/L Column 1 4.6 mmI.D.150 mm 4.00 2 3 Eluent CH3CN / H2O = 60 / 40 (v/v) 3.50 4 Flow rate 1.0 mL/min 3.00 Column 5 40C temperature 2.50 6 Detection DAD 360 nm mAU 7 2.00 8 Injection volume 10 µL 1.50 [System configuration] 1.00 5110 Pump 0.50 5210 AutoSampler 5310 Column Oven 0.00 5430 DAD -0.50 Empower2 Data Processing System 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 min分 Chromatogram of 2.4–DNPH-derived aldehydes (concentration of each: 0.5 mg/L) [Notes] 0.07 mg/L(0.07 ppm), the concentration of formaldehyde in the sample solution, is equal to a concentration of 0.02 µg/m3 formaldehyde in ambient air eluted with acetonitrile at a constant volume (10 mL) after collection via suction with a pump at 1 L/min for 30 minutes, as shown in Figure 1. Therefore, the Chromaster is suitable for measurement of formaldehyde at concentrations of 100 µg/m3, the indoor concentration monitoring standard for formaldehyde established by Ministry of Health, Labor and Welfare, and 0.1 ppm, the control concentration established by the Occupational Health and Safety Law. NOTE: These data are an example of measurement; the individual values cannot be guaranteed. The system is for research use only, and is not intended for any animal or human therapeutic or diagnostic use.. Hitachi High-Technologies Corporation.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us