MTGW Installation Guide EN CAN-RS-485 BUS Gateway MTGW | Installation Instructions | 1.0 Overview CAN bus wiring requirements are as follows: Trademarks • CAN Bus Interface: Connect the CAN bus to the Microsoft® Windows® 98/2000/XP are registered MTR Communication Receiver with at least trademarks of Microsoft Corporation in the United 1.5 mm (16 AWG) shielded twisted-pair wire; States and other countries. maximum length: 2000 m (6500 ft). • RS-485 Buses 1-3: Use at least 1.0 mm (20 AWG) 1.0 Overview shielded twisted-pair wire for the RS-485 bus; maximum length: 1200 m (3900 ft). RS-485 bus 1.1 Multi-Tenant System (MTS) Overview wiring status is supervised. MTS is a distributed security system for monitoring 1.2 MTS Device Address and controlling a large number of small sites. You must assign an address to each device in the Examples include apartment and condominium system. The address consists of at least four segments. complexes, retail plazas, office buildings, and For example: educational and hospital campuses. 1.2.5.3.6 A typical MTS installation consists of the following components: • 1: This segment identifies the number assigned to the MTR central receiver (1 to 99). • MTSW Security Station Software: MTSW is an ® ® • 2: This segment identifies the CAN bus number application based on Microsoft Windows , occupied by the MTGW (1 or 2). installed on a PC and monitored by guard station • personnel. 5 : This segment identifies the MTGW’s CAN bus address (1 to 100). • MTR Communication Receiver: The MTR • receives and handles alarm events from devices 3 : This segment identifies the device’s RS-485 connected to the CAN RS-485 bus. It monitors address (1 to 120). and reports CAN bus status and other system • 6 : This segment identifies the zone number of an internal events, and interfaces with MTSW to input or output device connected to the RS-485 synchronize system data. device. • MTGW CAN RS-485 Bus Gateway: The MTGW To set the DIP switch address on this device, refer to converts data back and forth from an RS-485 Section 4.0 Setting DIP Switches on page 5. format to a Controller Area Network (CAN) bus 1.3 MTGW Overview format. The system supports up to 100 MTGWs on each CAN bus line. The MTGW provides three The MTGW CAN RS-485 Bus Gateway is used in RS-485 loops that support a total of 120 RS-485 Bosch Security Systems, Inc. Multi-tenant Systems devices spread across the three loops. (MTS) to convert data sent over an RS-485 Bus into a format usable by a Controller Area Network (CAN) • RS-485 Bus Devices: Refer to Table 1 for a list of bus, and to convert CAN bus data into a format usable supported RS-485 devices. by an RS-485. This data includes events that occur at Table 1: MTS RS-485 Bus Devices devices attached to an RS-485 and commands sent from the Multi-tenant Receiver (MTR) Central Receiver to the devices. The MTGW can buffer up to RS-485 Device Description 64 events for conversion. It also monitors the DS6R2 Six Zone Keypad Controller connection status of the entire CAN and RS-485 nodes. IUI-DS12R Twelve Zone Keypad Controller Each Multi-tenant Gateway (MTGW) has three MT1-1 Single Zone Input Module separate RS-485 buses. The MTGW has one RS-232 ICP-MT1-2 Two Zone Input Module interface for upgrading firmware. MT1-8 Eight Zone Input Module ICP-MT2-8 Eight Relay Output Module ICP-MT3-1 One Input/One Output Module 2 Bosch Security Systems, Inc. | 4/08 | F01U009985-03 MTGW | Installation Instructions | 2.0 Wiring . One MTGW has three isolated RS-485 bus terminal 2.0 Wiring pairs. Each MTGW can support up to 120 RS-485 • Install the MTGW according to this devices, including the DS6R2 Keypad Controller, document to avoid damage to the MT1-1 Single Zone Input Module, MT1-8 Eight Zone devices. Input Module, IUI-DS12R Twelve Zone Keypad Controller, ICP-MT1-2 Two Zone Input Module, • Remove power to the MTGW before ICP-MT2-8 Eight Relay Output Module, and connecting or removing it. ICP-MT3-1 One Input/One Output Module. Divide • Perform a system test after the the devices as evenly as possible across all three installation to verify that all functions terminals for improved system loading and fault work properly. tolerance. Refer to Table 2 and Figure 1. Table 2: Power and Wiring Specifications* Power Supply Input 18.5 VAC provided by transformer (included) Accessory Output Power 500 mA maximum Battery 12 V battery connectors; chargeable; battery status is monitored Recommended battery: 12 VDC, 7 Ah sealed lead-acid (at least 12 V 3 Ah) Wiring CAN bus interface Connect the CAN Bus to the MTR Central Receiver with at least 1.5 mm (16 AWG) shielded twisted-pair wire; maximum length, 2000 m (6500 ft). RS-485 Bus 1 1.0 mm (20 AWG) shielded twisted-pair wire for the RS-485 bus. RS-485 Bus 2 Maximum length, 1200 m (3900 ft). RS-485 Bus 3 RS-485 bus wiring status is monitored. * Refer to Table 3 on page 4 for detailed specifications. Figure 1: System Diagram CAN 1 CAN 2 MTR Central Receiver MTGW MTGW RS-485 RS-485 RS-485 RS-485 RS-485 RS-485 1 2 3 1 2 3 DS6R2 DS 6R2 DS6R2 DS6R2 DS6R2 DS6R2 MT1-8 MT1-8 MT1-8 MT1-8 MT1-8 MT1-8 MT1-1 MT1-1 MT1-1 MT1-1 MT1-1 MT1-1 Bosch Security Systems, Inc. | 4/08 | F01U009985-03 3 MTGW | Installation Instructions | 2.0 Wiring Figure 2: MTGW Circuit Board and Interface Description 1 2 3 4 15 14 13 12 11 10 9 8 7 6 5 Table 3: MTGW Description and Specifications Figure 2 Callout Description Description and Specifications Callouts 1 CAN BUS ADDRESS DIP switch address of the MTGW on the CAN bus (refer to Section 4.0 Setting DIP Switches on page 5). 2 RS-485 DEVICE DIP switch addressing for the amount of installed RS-485 devices (refer to Section 4.0 AMOUNT Setting DIP Switches on page 5). 3 RS-232 programming RS-232 programming port; use to upgrade MTR firmware (refer to Section 3.0 MTGW port Firmware Upgrade on page 5). 4 TAMPER Tamper switch terminals (2); connect to tamper switch wires in the MTGW’s enclosure 5 COM Common ground (optional) 6 RS-485 A3 and B3 RS-485 Bus 3 Use at least 1.0 mm (20 AWG) Use standard CAN or 7 RS-485 A2 and B2 RS-485 Bus 2 (shielded* twisted-pair wire for the RS-485 repeaters to RS-485 bus; maximum length increase the wiring run for 8 RS-485 A1 and B1 RS-485 Bus 1 1200 m (3900 ft). both the CAN Bus and 9 RESET Reset Button RS-485 bus wiring status is RS-485 bus. Multi- monitored. repeaters can be used in one system. 10 CANH and CANL CAN bus interface Connect the CAN Bus to the MTR Central Receiver with at least Avoid branch wiring 1.5 mm (16 AWG) shielded* (T-taps or star topology) the twisted-pair wire; maximum length CAN and RS-485 bus. 2000 m (6500 ft). 11 EOL jumper CAN bus EOL jumper. This jumper must be closed on the last MTGW on the bus. 12 BATT + and – 12 V battery connectors; chargeable; MTGW 100 mA standby battery status is monitored Current Up to 1500 mA @ 13.5 V ± 5% Recommended battery: 12 VDC, 7 Ah Draw: when using both the battery sealed lead-acid (at least 12 VDC 3 Ah) charging and auxiliary outputs 13 AUX + and – Accessory output power Output: 13 VDC ± 5% for battery charging 500 mA maximum and auxiliary power 14 EARTH Earth ground 15 AC1 and AC2 Power Supply: Input 18.5 VAC provided by transformer (included) * To terminate shielded twisted-pair wire, ground the bus by connecting the wire to the MTGW’s COM terminal. 4 Bosch Security Systems, Inc. | 4/08 | F01U009985-03 MTGW | Installation Instructions | 3.0 MTGW Firmware Upgrade . 3.0 MTGW Firmware Upgrade Figure 3: Binary Address 0000110 Upgrade the MTGW firmware using MTRAM, a ON DIP Windows PC application software with a Chinese and English interface. It is provided as a separate tool in the Multi-tenant Software (MTSW) CD (P/N: F01U011231). 0123456 1. Connect the PC COM port to the RS-232 port, Figure 2, Item 3 on page 4 using an RS-232 cable. CAN BUS ADDRESS is the address of the MTGW The cable is included with the MTR. on the CAN bus. The RS-485 DEVICE AMOUNT equals the number of RS-485 devices connected. 2. Insert the MTSW CD into a PC that supports ® Refer to Figure 2, Items 1 and 2 on page 4. For each Windows 98/2000/XP. CAN Bus, you can connect up to 100 MTGWs. The 3. Select System→Management→Firmware highest binary address is 1100100, which Utilities→Manual Upgrade Wizard, then corresponds to an address of 100. select MTGW and follow the software’s You can connect 120 RS-485 devices. The highest instructions to finish the firmware upgrade. binary amount for the RS-485 Bus is 1111000, which MTRAM opens automatically and guides you corresponds to 120. Use Table 5 on page 6 to through the installation. determine the appropriate address settings for the 4. Press the RESET button on MTGW to start the devices on your system.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages8 Page
-
File Size-