
Effect of Photon Counting Shot Noise on TIRM Fan Cuia and David J. Pineab Total internal reflection microscopy (TIRM) measures changes in the distance between a colloidal particle and a transparent substrate by measuring the intensity of light scattered by the particle when it is illuminated by the evanescent field that is created from light totally internally reflected at the substrate interface. From these measurements, the height-dependent effective potential j(z) between the colloidal particle and the substrate can be measured. The spatial resolution with which TIRM can resolve the height z and effective potential j(z) is limited by the intrinsic shot noise of the photon counting process used to measure the scattered light intensity. We develop a model to determine the spatial resolution with which TIRM can measure j(z) and verify its validity with simulations and experiments. We establish the critical role of shot noise and intensity integration time t in TIRM measurements of colloidal interaction potentials, which is a trade-off between minimizing shot noise and preserving the spatial resolution of the potential. 1 Introduction evanescent wave, which is typically in the range of 70-200 nm. Total internal reflection microscopy 1 (TIRM) is a powerful Because the intensity I of the light scattered by the particle is pro- method for measuring the microscopic interactions of colloidal portional to the intensity Ie of the evanescent field that is incident particles in a liquid suspension. Since its development some 30 on the particle, the scattered intensity also depends exponentially years ago, 2 it has been used to measure various colloidal interac- on the height of the particle, 1,8 tions, including screened electrostatic repulsion, 3 steric repulsion −bz due to grafted or adsorbed polymers, 4,5 van der Waals attrac- I(z) = I0 e : (3) tion, 4 depletion attraction, 6 and critical Casimir interactions. 7 Thus, we see that the scattered intensity is related directly to the Spatial resolutions as small as 1 nm have been reported. 2 As such, height z of a particle. This gives us a way to determine the height TIRM has become an invaluable tool for understanding colloidal z of the particle. interactions at a microscopic scale. The probability P(I)dI that the scattered intensity is between I Figure 1 shows a schematic of a typical TIRM experiment and and I +dI is the equal to the probability p(z)dz that the particle is summarizes the basic experimental setup. between a height of z and z + dz, and thus are related by The TIRM technique is based on two simple ideas. First, the probability that a particle at equilibrium in a liquid suspension P(I)jdIj = p(z)jdzj : (4) is at a height z above the substrate is given by the Boltzmann distribution Solving for p(z) yields, p(z) = Ae−j(z)=kBT ; (1) dI p(z) = P(I) = b P(I)I(z) ; (5) dz where j(z) is the effective interaction potential between the par- ticle and the substrate. Inverting this equation, we obtain the where we have used eqn (3) to evaluate the derivative. Thus, the expression probability distribution of heights p(z) appearing in eqn (2) can j(z) − j(z ) p(z ) r = ln r ; (2) k T p(z) B photon counter where we have introduced a reference height zr to eliminate the normalization factor A that appears in eqn (1). Equation (2) tells us that if we can measure the distribution of particle heights p(z) arXiv:2109.11651v1 [cond-mat.soft] 23 Sep 2021 above the substrate, we can determine the effective interaction between the particle and the substrate. particle The second idea starts with the observation that the evanes- cent intensity Ie of light totally internally reflected from the z substrate decays exponentially with height above the substrate, laser beam −1 Ie(z) = Ie0 exp(−bz), where b is the penetration depth of the prism Fig. 1 TIRM schematic. Laser light enters from the right and is totally internally reflected at the substrate, launching an exponentially-damped a Department of Physics, Center for Soft Matter Research, New York University, 726 evanescent wave towards the particle, which is a distance z above the sub- Broadway, New York, NY 10003, USA. E-mail: [email protected], [email protected] strate in a liquid suspension. Light scattered by the particle is collected b Department of Chemical & Biomolecular Engineering, Tandon School of Engineering, by a microscope objective lens and directed toward a photon counter. New York University, 6 MetroTech Center, Brooklyn, New York 11201, USA. 1–10 | 1 Reconstruction in ALICE and calibration of TPC space-charge distortions in Run 3 Ernst Hellbär0,∗for the ALICE collaboration 0GSI - Helmholtzzentrum für Schwerionenforschung GmbH E-mail: [email protected] The ALICE experiment will run with continuous readout at interaction rates of up to 50 kHz in Pb–Pb collisions during Run 3 of the LHC. In order to achieve this goal, a new data processing scheme and software are developed. This scheme strongly relies on GPUs (Graphics Process- ing Unit) for fast online and offline calibration and reconstruction as well as on efficient data compression. On the hardware side, the Time Projection Chamber (TPC), among other detector systems, received major upgrades to its readout chambers and readout electronics. The multiwire proportional chambers were replaced by stacks of four Gas Electron Multiplier foils to allow for continuous readout while keeping the ion backflow below 1%, minimizing space-charge effects from amplification ions entering the drift volume. Nevertheless, significant space-point distortions due to space charge are expected at the highest interaction rates in Pb–Pb collisions. In addition, space-charge density fluctuations lead to distortion fluctuations which have to be corrected on time scales of 10 ms in order to preserve the intrinsic tracking resolution of the TPC. While the average space-charge distortions can be corrected using information from external detectors as a reference, data-driven machine learning algorithms and convolutional neural networks are foreseen to provide the correction for the distortion fluctuations. arXiv:2109.12000v1 [physics.ins-det] 24 Sep 2021 The Ninth Annual Conference on Large Hadron Collider Physics - LHCP2021 7-12 June 2021 Online ∗Speaker © Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0). https://pos.sissa.it/ Reconstruction in ALICE and calibration of TPC space-charge distortions in Run 3 Ernst Hellbär 1. Introduction The ALICE experiment aims to record a Pb–Pb minimum-bias data sample in Run 3 and Run 4 of the LHC which is 50–100 times larger than that recorded in the first two running periods. This will be realized by fully exploiting the capabilities of the LHC, which will deliver Pb–Pb collisions at interaction rates of up to 50 kHz. Contrary to the event-based triggered readout which was employed before Run 3, ALICE will now continuously process and record the data provided by the detectors, i.e. data from every collision will be available. Continuous readout poses several chal- lenges and new requirements for the global data processing strategy [1], including the calibration and reconstruction software and, for some of the detector systems, also requiring hardware up- grades. The data processing is performed in two stages, synchronous processing and asynchronous processing. The former takes place during data taking and includes a first calibration and tracking, while the final calibration and full reconstruction of the data is performed during the asynchronous processing at a later point in time. At both stages, the application of GPUs for a majority of the processing leads to a significant gain in computing time, which is required to continuously process the amounts of data expected to be delivered in Run 3 and Run 4. The Time Projection Chamber (TPC) [2] is the main detector for tracking and particle identifi- cation in ALICE. During the long shutdown of the LHC before Run 3, the readout chambers and electronics were upgraded [3] in order to provide the capability to run in continuous readout mode. Instead of multiwire proportional chambers and a triggered gating grid, which effectively limited the readout rate to about 3 kHz in order to avoid space-charge effects from ion backflow (IBF), the upgraded readout chambers are based on Gas Electron Multiplier (GEM) foils. A combination of four GEM foils with different hole pitches and an optimized high-voltage configuration suppresses the IBF to below 1%, eliminating the need for a gating grid and allowing the operation of the detector with continuous readout. Taking into account the high interaction rates foreseen for Pb–Pb collisions in Run 3, significant space-point distortions due to space charge from IBF are still ex- pected, requiring a sophisticated calibration approach to preserve the intrinsic tracking performance of the TPC. 2. Space-charge effects in the TPC The space-charge density depends on the amount of ions piling up within one ion drift time. It is driven by the number of ion pile-up events, which is the product of the collision rate and the ion drift time, as well as by the effective gain and the IBF, which are combined to Y = gain × IBF. The expected space-charge density distribution at 50 kHz Pb–Pb is derived using the hit distributions from Monte Carlo simulations. As dedicated measurements of the ion mobility in Ne-CO2-N2 (90-10-5) [4] indicate an ion drift time around 200 ms for the full drift, ions from 10000 events pile up on average in the TPC drift volume at any given moment at 50 kHz interaction rate.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages39 Page
-
File Size-