Grannie: a Scalable, Interactive, Artificial Intelligence Supervisory System for Medical Devices

Grannie: a Scalable, Interactive, Artificial Intelligence Supervisory System for Medical Devices

GRANNIE: A SCALABLE, INTERACTIVE, ARTIFICIAL INTELLIGENCE SUPERVISORY SYSTEM FOR MEDICAL DEVICES Paul Frenger MD A Working Hypothesis, Inc., P.O. Box 820506, Houston, TX 77282-0506 USA [email protected] ABSTRACT tached or embedded, intelligent, modular, open- systems, multiprocessor robotic control network Complex medical devices are difficult for patients on-or-in medical devices (as appropriate) to im- to use. The author suggests putting a biologically- prove patient interaction and supervision. These inspired, intelligent, modular, open-systems robot “smart” systems would replace a medical device’s control network into these devices for improved original complex user interface with a more intui- patient interaction and supervision. The author’s tive, patient-friendly one. system, GRANNIE (an acronym for “Generalized Some inspiration for this project came from Robotic Accessory with Neural Network, Intellect “terminal emulation” methodology, typically and Emotions”) emulates human sensory, motor, where decades-old financial applications running cognitive and emotional responses. GRANNIE has on obsolete mainframe computers are controlled a processor-neutral hardware bus and software by graphical-windowed PCs which interface these which is independent of CPU or programming programs in a more user-friendly fashion [1]. language. Improved plug-and-play functions and Encouragement also came from successful transducer interoperability were recently added. adaptations of my robot control system (RCS) Scalability for various hardware configurations is “ANNIE” (an acronym for Android with Neural provided. GRANNIE technology will help to cre- Network, Intellect and Emotions) [2] into artificial ate user-friendly, safety-promoting interactive su- intelligence (AI) areas: emulating human emo- pervisors for many varieties of medical devices. tions, cognition, brain growth and development [3], hormone functions and response to medica- KEYWORDS tions. My ANNIE AI design appeared to be flexi- ble enough to be developed into a customizable, IEEE P996.1, IEEE 1275, IEEE 1451.4, Artificial intelligent, anthropomorphic interface for medical Intelligence, Computer Network, Medical Device, devices and equipment. Motor System, Sensory System, Robotics MATERIALS AND METHODS INTRODUCTION 1. The Basic ANNIE Design: Devices for diagnostic, assistive, rehabilitative My ANNIE RCS design includes biologically- and eldercare services are increasingly complex inspired modalities: head and torso control, facial and difficult for patients to use without extensive gesturing, a dexterous hand, speech recognition / training and human supervision. For example, synthesis, artificial vision with optical character there are many brands and models of diabetic glu- recognition (OCR), sensation of pressure, humid- cose monitors on the market, each having unique ity, temperature and proprioception; and several human interfaces, calibration methods, blood col- which are non-biological: navigation (magnetic, lection requirements, data storage and download- inertial and GPS), ranging (ultrasonic and laser), ing techniques, and report printing procedures. To and communication (infrared / radio / cell phone). alleviate this problem, I suggest creation of an at- She does not walk but is wheelchair-mobile. ANNIE utilizes the IEEE P996.1 (PC/104) Network, Intellect and Emotions). GRANNIE processor-neutral hardware bus [4]. PC/104 cards technology may be employed in two ways: it may are slightly larger than 3.5-inch diskettes and can be placed in a separate chassis for interfacing with be connector-stacked on 0.6-inch centers to add existing medical devices, or it can be embedded functions. ANNIE has PC/104 prototyping cards within future enhanced medical devices. stacked on her CPU card to provide hardware co- processors for artificial neural network (ANN), 3. The Proof-of-Concept Experiments: OCR, emotion emulation, and content-addressable The initial GRANNIE proof-of-concept test memory (CAM) text-indexing accelerators. The involved simulating an interface between a blood head and extremities are controlled by networked glucose meter and the GRANNIE system. The regional processors. All hardware coprocessors emulated glucometer is the Roche Diagnostics have software-only versions available. ACCU-CHEK® Advantage® blood glucose me- ANNIE’s command software and AI functions ter. Instructions for using this unit and its specifi- employ a machine-independent, programming lan- cations are given in the owner’s booklet [12]. This guage-independent byte-coded script language device has three buttons, a multipurpose LCD based on an extension of the IEEE 1275-1994 display and a tone generator as the principal user (Open Firmware) standard [5], which contains a interface. A serial TTL UART jack is provided for Forth language compiler [6], but which may be data transfer to a personal computer, as is a slot implemented in ANSI C [7] or other computer for test-strip-specific electronic code keys. The languages. Open Firmware is employed by IBM, glucometer stores up to 480 test results (time and Apple Macintosh, and Sun Microsystems (under date stamped) for downloading to a PC. the trade name OpenBoot) for computer booting and plug-and-play initialization. A free portable version is available [8]. Normally after bootup Open Firmware loads another operating system over itself, but it can be used stand-alone [9]. ANNIE’s data files contain a knowledge base (64,000 words per dictionary in multiple lan- guages such as English and French), her personal- ity parameters, and her experience history. Also stored there is the AI schema-script system (a schema is a memorized data structure which has features of a digital neuron for decision-making, and a rule-based expert system for action control) [10]. ANNIE’s schema scripts are generally used in “subject-verb-object” format. I recently improved this design by adding a novel IEEE 1451.4 subsystem with enhanced plug-and-play and transducer interoperability to the base IEEE 1275 RCS [11]. 2. GRANNIE Adds Features Onto ANNIE: Extending ANNIE’s functions, I have de- Figure 1. GRANNIE – Glucometer Test Setup signed a medical device interface proof-of- concept system I call GRANNIE (which stands The hardware used in this test included a 500 for Generalized Robotic Accessory with Neural MHz PC/104 x86-type computer, to perform the GRANNIE functions. The glucometer emulator I then asked GRANNIE to request several was embodied in a “Flashlite” 4.2 by 3.6 inch sin- blood glucose tests from the SBC. Values be- gle board computer (SBC) containing an 8 MHz tween “0 mg/dl” and “255 mg/dl” (depending on NEC V25 (8086-like) controller [13]. The SBC the potentiometer setting on the SBC’s A/D port) has two flash ROM disk drives and an MS/DOS were displayed on GRANNIE’s PC display. 3.3 file system, a TTY serial port (for program- GRANNIE was next asked to request a down- ming and control), a secondary serial data port and load of the meter values in the SBC’s memory; A/D input channels. The glucometer-emulator these were also displayed on GRANNIE’s PC. SBC conversed with GRANNIE over the SBC’s Following this, GRANNIE was asked to tell second serial data port. As depicted in Figure 1, the SBC to clear its meter memory. one PC was attached to GRANNIE’s TTY port, These test runs simulated the operations an and another was attached to the SBC TTY port, actual glucometer user would routinely perform. for observation and control of each system. All were accomplished successfully, albeit with A Forth-83 interpreter (called “Flash-Forth”) some bug-eliminating adjustments to the SBC’s was installed on the SBC, in which the glucometer Forth program and GRANNIE’s schema scripts. simulator program was written. GRANNIE’s glu- cometer control and reading functions were cre- DISCUSSION ated as schema scripts specifically written to sup- port this particular SBC emulator. These first tests of GRANNIE’s capabilities To simplify testing, only the following glu- may not seem very challenging (except for its cometer functions were included: run a level 1 natural language AI input processing), but they control test; take a blood glucose reading; down- suggest her future potential. Subsequent testing load meter memory to computer; and clear mem- will be conducted with GRANNIE’s visual, OCR, ory. To further simplify tests, GRANNIE’s visual, auditory, speech recognition / synthesis and dex- OCR, auditory, speech recognition / synthesis and terous hand control systems re-enabled. This will dexterous hand control systems were disabled; allow users to verbally ask GRANNIE to perform instead, direct UART-to-UART data transfers the various functions on an actual glucometer and emulated these functions. hear GRANNIE recite the results. GRANNIE will Different simulated blood glucose values were be able to read the glucometer’s LCD, hear its produced by turning a potentiometer connected to buzzer and press its buttons to navigate the con- the SBC’s A/D input. Time and date values were trol menus in place of the user. obtained from the SBC. Test readings were down- An important future issue is providing scal- loaded as ASCII comma-separated-values (CSV). ability for GRANNIE over a variety of hardware configurations to accommodate 8 / 16 / 32 / 64-bit RESULTS CPUs with widely divergent memory capacities. Scalability is the obverse of code transportability. Multiple tests were run using the above ex- Currently, use of IEEE 1275 byte-code processing perimental setup, conducted as follows. software virtual machines (VM) created in the A communications check verified that the Forth and C languages makes this possible. Brad SBC glucometer and GRANNIE were talking to Eckert’s version of IEEE 1275 written in C runs each other and to their respective PCs. on 8-bit and 32-bit CPUs, requiring just 14 Kbytes I asked GRANNIE to request an initial level 1 combined ROM-RAM on the former and 24 control test from the SBC. The SBC reported “55 Kbytes ROM-RAM on the latter [14]. Using a mg/dl” (the strength of the actual glucometer test- FIG-Forth software VM byte-code processor ing solution) which GRANNIE displayed on the would allow use on any 8-bit to 64-bit CPU with a PC attached to her TTY port.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us