Free Standard provided by BIS via BSB Edge Private Limited to Directorate State Fire Prevention Services - Gandhinagar([email protected]) 43.250.164.250 [for non-commercial use only]. IS 8758 : 2013 Hkkjrh; ekud vLFkkbZ ljapukvksa vkSj iaMkyksa ds fuekZ.k esa vfXu 'keu ds fy, ,gfr;krh mik; µ jhfr lafgrk ¼ nwljk iqujh{k.k ½ Indian Standard FIRE PRECAUTIONARY MEASURES IN CONSTRUCTION OF TEMPORARY STRUCTURES AND PANDALS — CODE OF PRACTICE ( Second Revision ) ICS 13.220.01 © BIS 2013 B U R E A U O F I N D I A N S T A N D A R D S MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002 May 2013 Price Group 3 Free Standard provided by BIS via BSB Edge Private Limited to Directorate State Fire Prevention Services - Gandhinagar([email protected]) 43.250.164.250 [for non-commercial use only]. Fire Safety Sectional Committee, CED 36 FOREWORD This Indian Standard (Second Revision) was adopted by the Bureau of Indian Standards, after the draft finalized by the Fire Safety Sectional Committee had been approved by the Civil Engineering Division Council. Temporary structures including large pandals normally erected at fairs, festivals and such other outdoor assembly have not, in general, been subjected to adequate regulations from fire safety point of view though in certain regions certain minimum fire precautionary measures in the construction of such structures are ensured before giving a licence or permission for the erection of such structures. Therefore, with a view to give necessary guidance with regard to fire protection measures to be adopted in the erection of such structures, it has been felt necessary to formulate this standard. This standard was first published in 1978, covering the safety aspects for temporary structures and pandals used by public excluding the temporary structures used for private functions. Since then the number of Indian Standards in regard to details of construction, fire safety and equipment have been formulated. The standard was revised in 1993 wherein having seen the more usage of temporary structures for private functions, the scope of this standard was enlarged to cover such type of structures also. This revision has been prepared so as to cover details of construction and use of fire fighting equipment according to the latest standards. Further the provisions have been aligned with National Building Code 2005. The composition of the Committee responsible for the formulation of this standard is given in Annex A. Free Standard provided by BIS via BSB Edge Private Limited to Directorate State Fire Prevention Services - Gandhinagar([email protected]) 43.250.164.250 [for non-commercial use only]. IS 8758 : 2013 Indian Standard FIRE PRECAUTIONARY MEASURES IN CONSTRUCTION OF TEMPORARY STRUCTURES AND PANDALS — CODE OF PRACTICE ( Second Revision ) 1 SCOPE minimum of 10 minutes or total evacuation time whichever is more. This standard covers the fire safety in respect of construction, location, maintenance and use of 3.1.1 Each temporary structure shall be permitted only temporary structures including pandals used by public in Fire Zones No.1 & 2 as the case may be, according and private functions for outdoor assembly. to the purpose for which these are to be used, by special permit from the authority for a limited period and the NOTE — Temporary structure shall apply to all structures with roof or walls made of straw, hay, ulu grass, golpatta, hogla, provisions of this standard shall be complied with. darma, mat, canvas cloth or other like material which is not adopted for permanent or continuous occupancy. 3.1.2 Such temporary structures shall be completely removed on the expiry of the period specified in the 2 REFEERENCES permit. The Indian Standards given below contain provisions 3.2 The choice of materials for such constructions shall which, through reference in this text, constitute preferably be of non-combustible or fire resistance provisions of this standard. At the time of publication, type. The materials used for the decor shall be such the editions indicated were valid. All standards are that it shall not generate toxic smoke/fumes. Wherever subject to revision and parties to agreements based on materials of combustible nature are used these shall this standard are encouraged to investigate the be treated with a fire retardant material of Class-I flame possibility of applying the most recent editions of the spread of IS 12777. standards indicated below: 3.3 The main structure shall be erected with at least IS No. Title 100 mm diameter post of non-combustible material or 1646 : 1997 Code of practice for fire safety of wooden post (preferably of sal, casurina or bamboo) buildings (general): Electrical and the rest of the structure may be of lighter poles installations (first revision) and trusses tied/screwed properly with steel wire. The 2190 : 1992 Selection, installation and poles and trusses shall be nailed/screwed, wherever maintenance of first-aid fire required. All supporting members shall be of sufficient extinguishers — Code of practice size and strength to support the structure. (second revision) 3.4 The height of the ceiling of the structure or pandal 12349 : 1988 Fire protection — Safety signs from the ground shall not, in any case, be less than 3 m. 12407 : 1988 Graphic symbols for fire protection plans 3.5 No decorative paper/synthetic material shall be used 12777 : 1989 Method for classification of flame — anywhere in the pandal/structure. Spread of products 3.6 All fabrics, decorative clothing used in the 15612 (Part 1) : Textiles — Burning behaviour to construction and decoration of the structure shall 2005 curtains and drapes: Part 1 conform to IS 15612 (Part 1) and IS 15741. Classification scheme 15741 : 2007 Textiles — Resistance to ignition of 3.7 No nylon or synthetic ropes shall be used anywhere curtains and drapes — Specification in the structure. Only ropes made of coir, manila or coconut fibres shall be treated with fire retardant 3 GENERAL REQUIREMENTS solutions in accordance with 3.2 before use. 3.1 The materials, design, construction, fabrication of 3.8 Temporary structures shall be adequately guyed/ structures or devices within the scope of this standard braced and made secure to withstand a wind pressure shall meet the requirements for resistance to fire of a of 0.98 kN/m2 (0.01 kgf/cm2). 1 Free Standard provided by BIS via BSB Edge Private Limited to Directorate State Fire Prevention Services - Gandhinagar([email protected]) 43.250.164.250 [for non-commercial use only]. IS 8758 : 2013 3.9 In no case, the height of corridor/passageway shall provided, depending on the capacity of the assembly, be less than 3 m. as given in 7.3 to 7.9. 4 LOCATION 7.3 A minimum of two exits of not less than 2.5 m width separately, located at extremities from each other, 4.1 There shall be a clear space of 4.5 m on all sides shall be provided for any type of temporary structures. between the structure and the adjacent buildings or other structures. In cases where temporary structures 7.3.1 Each of the exits shall be minimum 3 m wide for are erected in the lawns which are part of residential larger pandals and these exits may be provided after premises, the entire frontage shall be kept open. gap of 10 m. 4.2 No temporary structure shall be erected beneath 7.4 The clear width of exits shall be determined on the and adjacent to any live electrical line. The gap between basis of not less than one unit of 50 cm for each 50 the live wires and any part of the structure shall in no persons to be accommodated. The width of each exit case be less than 2 m. shall not be less than 2.5 m. 4.3 No temporary structure shall be erected near 7.5 The line of travel from any seat to the nearest exit furnace, railway line, electrical sub-station, chimney on the seating area shall not be greater than 15 m. or under high tension wire or like hazard unless a safety 7.6 All exit points shall be clearly indicated with sign distance of 15 m is maintained. ‘EXIT’ (including in local language) over each door- way or opening in plain legible letters ( not less than 5 MEANS OF ACCESS 5 cm high and with principal strokes of such letters 5.1 All temporary structures shall be approachable and not less than 1.8 cm in width) enabling everybody in the gate provided shall have a clear opening of 5 m. the auditorium to visualize the exit points easily. Fire Arch way shall not be at a height less than 5 m from protection-safety signs and fire protection plans shall the ground level. be in accordance with IS 12349 and IS 12407. 5.2 The temporary structure shall be approachable to 7.6.1 Exit light should be adequately illuminated with fire engine. No part of temporary structures shall be reliable light source when the structure is occupied by more than 45 m away from the motorable road. the public. Suitable directions signs shall be displayed in a conspicuous location to indicate the proper 6 CAPACITY direction of egress. Exit and direction signs shall also 6.1 The capacity of any temporary structure or pandal be painted with fluorescent paint. Doors wherever fitted or enclosure for outdoor assembly shall be the number to exits shall open outwards and shall not be closed or of fixed seats plus an allowance of one person for each bolted during the presence of persons in the structure.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages9 Page
-
File Size-