Cephalometric Regional Superimpositions -- Digital Vs

Cephalometric Regional Superimpositions -- Digital Vs

Nova Southeastern University Masthead Logo NSUWorks College of Dental Medicine Student Theses, College of Dental Medicine Dissertations and Capstones 1-1-2014 Cephalometric regional superimpositions -- digital vs. analog accuracy and precision : 3. the cranial base Douglas Shaw Nova Southeastern University This document is a product of extensive research conducted at the Nova Southeastern University College of Dental Medicine. For more information on research and degree programs at the NSU College of Dental Medicine, please click here. Follow this and additional works at: https://nsuworks.nova.edu/hpd_cdm_stuetd Part of the Dentistry Commons Share Feedback About This Item NSUWorks Citation Douglas Shaw. 2014. Cephalometric regional superimpositions -- digital vs. analog accuracy and precision : 3. the cranial base. Master's thesis. Nova Southeastern University. Retrieved from NSUWorks, College of Dental Medicine. (18) https://nsuworks.nova.edu/hpd_cdm_stuetd/18. This Thesis is brought to you by the College of Dental Medicine at NSUWorks. It has been accepted for inclusion in College of Dental Medicine Student Theses, Dissertations and Capstones by an authorized administrator of NSUWorks. For more information, please contact [email protected]. CEPHALOMETRIC REGIONAL SUPERIMPOSITIONS – DIGITAL VS. ANALOG ACCURACY AND PRECISION: 3. THE CRANIAL BASE. DOUGLAS R. SHAW, D.D.S. A Thesis Presented to the Faculty of the College of Dental Medicine, Nova Southeastern University in Partial Fulfillment of the Requirements for the Degree of MASTER OF SCIENCE February 2015 Orthodontics © Copyright by Douglas R. Shaw 2014 All Rights Reserved CEPHALOMETRIC REGIONAL SUPERIMPOSITIONS – DIGITAL VS. ANALOG ACCURACY AND PRECISION: 3. THE CRANIAL BASE. By Douglas R. Shaw, D.D.S. A Thesis Submitted to the College of Dental Medicine of Nova Southeastern University in Partial Fulfillment of the Requirements for the Degree of MASTER OF SCIENCE Orthodontic Department College of Dental Medicine Nova Southeastern University November 2014 Approved as to style and content by: APPROVED BY:___________________________________________________ Richard Singer, D.M.D., M.S. (Committee Chair) Date APPROVED BY:___________________________________________________ Patrick Hardigan, Ph.D. (Committee Member) Date APPROVED BY:___________________________________________________ Abraham Lifshitz, D.D.S., M.S. (Committee Member) Date APPROVED BY:___________________________________________________ Linda C. Niessen, D.M.D., M.P.H., M.P.P. Date (Dean, College of Dental Medicine) NOVA SOUTHEASTERN UNIVERSITY Health Professions Division Department of Orthodontics College of Dental Medicine STUDENT NAME: Douglas R Shaw, D.D.S. STUDENT E-MAIL ADDRESS: [email protected] STUDENT TELEPHONE NUMBER: (801) 230-4643 COURSE DESCRIPTION: Master of Science TITLE OF SUBMISSION: Cephalometric Regional Superimpositions – Digital vs. Analog Accuracy and Precision: 3. The Cranial Base. DATE SUBMITED: November 10, 2014 I certify that I am the sole author of this thesis, and that any assistance I received in its preparation has been fully acknowledged and disclosed in the thesis. I have cited any sources from which I used ideas, data, or words, and labeled as quotations any directly quoted phrases or passages, as well as providing proper documentation and citations. This thesis was prepared by me, specifically for the M.S. degree and for this assignment. STUDENT SIGNATURE:____________________________________________________ Douglas R. Shaw, D.D.S. Date DEDICATION I would like to dedicate this to my wonderful wife and children who have supported me through this whole process. I could not have done this without you. I love you! ACKNOWLEDGEMENTS I would like to acknowledge everyone who assisted me in compiling this manuscript. I could never have done this without you and sincerely thank you all for the time and energy put forth in my behalf. I specifically would like to acknowledge my mentor Dr. Singer for pushing me to limits I never knew existed. I have learned a great deal along the way and am grateful for it. I want to acknowledge my co-residents Glenn Krieger and Kevin McCaffrey for being the help and support needed to complete this manuscript. I am forever grateful to you all. vi ABSTRACT CEPHALOMETRIC REGIONAL SUPERIMPOSITIONS – DIGITAL VS. ANALOG ACCURACY AND PRECISION: 3. THE CRANIAL BASE. DEGREE DATE: DECEMBER 12, 2014 DOUGLAS R. SHAW, B.S., UNIVERSITY OF UTAH D.D.S., UNIVERSITY AT BUFFALO SCHOOL OF DENTAL MEDICINE COLLEGE OF DENTAL MEDICINE NOVA SOUTHEASTERN UNIVERSITY Directed By: Richard Singer, D.M.D., M.S., Department of Orthodontics, College of Dental Medicine Nova Southeastern University Objective. To assess the accuracy and precision in measurement of pairwise implant displacement across three methods of cranial base superimposition. Background. Cephalometric superimposition is the principal radiographic method used to evaluate changes within the craniofacial skeleton. Many studies have examined the accuracy of software intended to produce cephalometric superimposition. Such studies have utilized anatomic landmarks, selected by the respective software manufacturers, as registration points for constructing superimpositions and their analysis. As a result, these studies are only as accurate as the stability and validity of anatomic registration landmarks used. To our knowledge, no other study has utilized metallic implants to critically assess digital vs. analog cephalometric cranial base superimposition. Methods. Serial cephalograms from twenty-two patients across three time points containing metallic implants were obtained vii from the Mathews Acquisition Group. Each of the sixty-six cephalograms was traced by hand and digitally. Cranial base superimpositions were completed according to the analog structural method proposed by Björk and Skieller, and Johnston, and then by Dolphin version 11.5 and Quick Ceph Studio V3.2.8 digital software according to manufactures instructions. Total displacement measurements of selected implants across paired time points were recorded for both digital methods and analog method of superimposition with analog serving as the reference. Results: There were no statistically significant contrasts of mean total displacement of implants by superimposition method (p = 0.999). No significant differences are reported in mean implant displacement when comparing digital to analog superimposition methods for contrasts by time, structure, or implant location. Conclusions: The results show that there are no significant differences in accuracy and precision of digital and analog cranial base superimposition. The results of this study suggest that cranial base superimpositions on S-Na that are registered on S may be a good approximation of the structural method of cranial base superimposition. There are many methodological differences between digital and analog cranial base superimposition and future research examining such differences is recommended. viii TABLE OF CONTENTS LIST OF TABLES ............................................................................................................. xi LIST OF FIGURES .......................................................................................................... xii CHAPTER 1: INTRODUCTION ....................................................................................... 1 1.1 Cephalometry - Historical Evolution. ....................................................................... 1 1.2 Superimposition ...................................................................................................... 12 1.2.1 Overview .......................................................................................................... 12 1.2.2 Structural Method ............................................................................................ 16 1.2.3 Regional Method .............................................................................................. 19 1.5 Radiography ............................................................................................................ 20 1.5.1 Analog .............................................................................................................. 20 1.5.2 Digital .............................................................................................................. 20 1.6 Digital Cephalometry .............................................................................................. 23 1.6.1 Challenges in Cephalometry. ........................................................................... 23 1.6.2 Digital vs. Analog Superimposition ................................................................. 24 1.7 Importance of the study .......................................................................................... 26 1.8 Purpose, specific aims and hypothesis .................................................................... 27 1.8.1 Purpose ............................................................................................................. 27 1.8.2 Specific Aims ................................................................................................... 27 1.8.3 Hypothesis........................................................................................................ 28 1.9 Location of Study .................................................................................................... 29 CHAPTER 2: MATERIALS AND METHODS .............................................................. 30

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    71 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us