STULZ Ultrasonic Humidification & EC Fan Retrofit

STULZ Ultrasonic Humidification & EC Fan Retrofit

Retrofit & Conditioning Ultrasonic Humidification Retrofit - EC Fans, Controller Replacement CRAH STULZ Ultrasonic Humidification & EC Fan Retrofit Kit Products and Services STULZ mission is to be the premier provider of energy efficient temperature and humidity control solutions for mission critical applications. ® www.STULZ.com STULZ, Your Trusted Partner STULZ is a global provider of innovative data center cooling solutions and services. Cooling Pre-Engineered Designed and Technology Leader Manufactured in STULZ products are available the U.S.A. STULZ is the technology in a variety of configurations leader, providing cooling and options based on our While some products are solutions and services for factory designed and tested merely assembled in America, mission critical applications. components and modules. STULZ is proud to research, This is accomplished We can also provide a design, manufacture, test through the design and custom touch to adapt and support our advanced manufacture of highly our products to meet your cooling technologies in our energy efficient temperature specific needs. Frederick, MD facility. and humidity control equipment for commercial Breadth and Depth STULZ products meet the and industrial applications. requirements of: With more than 20 years • Buy America Act Energy efficiency is at the of expertise in controls, core of every STULZ product economizers, and mission - including our HQ/Factory’s critical solutions, STULZ 950 kW solar array. offers the largest portfolio to fill any and all precision cooling needs. Product Support STULZ Product Support offers comprehensive service solutions to ensure our customers maximum efficiency and reliability. STULZ offers a comprehensive network of factory technicians and certified service partners throughout North America. STULZ Technical Support is available 24/7. Deployment Services: • Factory Authorized Warranty Inspection/Start-up • Basic Product Familiarization • BMS/Communication Services • Commissioning Assistance • Owner Training Planned Service: • Preventative Maintenance Contracts 2 www.STULZ.com Air Technology Systems, Inc. Benefits Summary & Comparisons STULZ • Provides precise static electricity & product quality control at a minimal operating cost • 93% less energy consumption than electric steam Ultrasonic • 90% smaller droplet than nozzles Humidifiers • Meets California Energy Commission Title 24 - 2013 Electric Steam High Pressure Design Attributes Infrared STULZ Ultrasonic Canister Nozzle Energy Consumption, kW per 100 lbs 33 43 0.3 2.4 of vapor Average Droplet Size, microns 1 NA 10-15 1 Feed Water Required Raw Raw Raw or Demi Demi Routine Maintenance Location Local Local Remote Remote Variable Control Type Analog NA Step Pulse Width Modulation Command to Action Time 2 minutes 3 minutes 1 Minute Instant Flush Cycle Requirement Regular Regular On Startup Periodic (optional) Evaporative Cooling No No Yes Yes Electric Utility Rebate Programs No No Yes Yes 100% Evaporation in Duct/AHU or Yes Yes No Yes Commericial Direct Room Application Complete Packaged Air Handling No No No Yes Humidifier/Water Treatment Systems • Improves overall performance of existing data center air conditioning equipment STULZ EC Fan • Eliminates maintenance & housekeeping associated with belt driven blower systems • Enjoy savings of 20% at constant speed and up to 60% at variable speed Retrofit Kit • Easy installation by a qualified HVAC technician Design Attributes VFD Only Under Floor ECM Blowers STULZ CyberMOD Can be installed in or under existing CRAHs and CRACs • • • Is easy to install in the field with the unit in place • • Replaces centrifugal fans and eliminates belt & dust • • Eliminates static regain requirement • • Reduces turbulence under floor • Eliminates DC to AC VFD conversion losses: 15%+ • • Provides drive redundancy with independent fan motors • • Increases motor life by removing harmonic speed limits and bearing effects • • Achieves lowest fan noise • Eliminates need to relocate infrastructure under floor • • Optimized blower performance with testing • Uses advanced controls with multiple analog input and outputs for various cooling / fan speed • strategies www.STULZ.com 3 STULZ Ultrasonic Humidifier State-of-the-art humidification for DRH - Direct Room Humidifier Wall or Shelf mission critical applications and any Mounted Units environment where clean, efficient, lbs/hr 4.4 - 17.6 and precise humidity control is kg / hr 2.0 - 8.0 required. DAH - Ducted Air Humidifier Duct and Air Handling Mounted Module 93% lbs/hr 5.3 - 39.6 energy kg / hr 2.4 - 18.0 Why Humidify? savings Today’s high tech environments require Design meticulous control of humidity • Multiple piezoelectric transducers immersed in a water bed impart high frequency oscillation to eliminate static electricity, • Alternating pressure and vacuum causes cavitation and production of very fine water mist ensure quality manufacturing • Average 1 micron diameter water droplets evaporate quickly in a room or moving air stream processes, preserve precious • All wetted surfaces are constructed of non-corrosive materials including plastic and stainless steel • Distributed power to the piezoelectric transducers is 48 Volts, AC or DC depending on application documents and works of art • Internal humidifier safeties include low and high water level switches and high temperature cutout and provide comfort while adhering to Indoor Air Quality standards. The specific Performance reasons to humidify are as • Adiabatic humidification process requires less than 10% of the energy required to boil water into steam numerous as the applications, • Evaporative cooling - improves efficiency of high sensible heat applications such as data centers but the purpose is common • All specifications and selections include mixed bed deionization water treatment systems by Culligan 100% of the demineralized water in the humidifier may be utilized and does not require a flush cycle across the board: to eliminate • • Extremely low operational expense equates to very short term Return on Investment (ROI) problems that can damage products, ruin buildings, or jeopardize health. Controls • STULZ Ultra-Series Proportional controls are engineered for single or multiple humidifier systems Indoor Air Quality affects • Utilizes STULZ E² Microprocessor Controller for integrated operation of up to 16 humidifiers per zone man and machine, and both • Ultra-Series control boxes enclose up to 8 power supplies each, providing power and control distribution operate best at optimum • Proportional analog output from microprocessor converted to Pulse Width Modulation at humidifiers • Monitors and communicates various system functions and alarms including water quality via integrated environmental conditions. • control and/or optional BMS A STULZ Ultrasonic Humidifier needs only 7% of the power required by an electric steam humidifier. Assuming a humidification requirement or 20 lbs/ Applications hr., a DAH-16 has a power requirement of 0.495 kW at 21.1 lbs/hr. Using a comparable capacity steam type humidifier, the power requirement is 6.8 kW at • Data Centers / Telecomm 20 lbs/hr, which is an energy premium of approximately 93%. • Libraries / Museums • High Tech Manufacturing In a typical application, the yearly humidification requirement is approximately • Printing / Duplication 2500-3000 hrs. ROI is typically 1-2 years verses Steam or Infrared. • Food & Beverage STULZ At a $0.08 per KWH utility rate: • Agriculture / Tobacco Energy Ultrasonic yearly power requirement.............= 3,000 hrs x 0.495 kW • Health Care Facilities = 1,485 kWH • Laboratories Analysis Yearly electrical energy cost........................... = 1,485 x $0.08/kWH • Commercial Offices = $118.80 Steam electrode yearly power requirement... = 3,000 hrs x 6.8 kW = 20,400 kWH Yearly electrical energy cost............................= 20,400 kWH x $0.08/kWH = $1,632 Yearly electrical energy savings................... = $1,513.20 4 www.STULZ.com 4 Air Technology Systems, Inc. DRH - Direct Room Humidifier DI Water • Mounts below the ceiling in a conditioned space Electrical 4 x DRH Units • On wall or column with factory furnished mounts • Suspended from above in open space • Integral blower and washable filter • Absorption distance determined by RH of room Ultra-Series Controller Demi- Cabinet Conditioned Space DAH - Ducted Air Humidifier • Mounts in moving air stream of AHU or ductwork DI Water Electrical • Multiple humidifiers assembled on factory rack system • Air velocity design similar to heating/cooling coils • Factory accessories for optimized airflow and mist control • Absorption distance determined by RH of airstream 4 x DAH Modules in Duct/AHU Section Skid Mount Ultra-Series RO/DI Controller Mechanical Room STULZ Water Treatment Demi-Cabinet Skid Mount RO/DI by • STULZ Demi-Cabinet enclosures for unitary • Culligan High Purity Reverse Osmosis (RO) plant RO and/or DI applied to small capacity and preconditioner for large capacity humidifier applications Mixed Bed Deionization (DI) provides high light commercial humidifier applications • CHP-250 to 8000 GPD RO/DI packages purity water quality specified for STULZ include prefiltration, storage, repressurization, UV Ultrasonic Humidification Systems sterilization, monitoring and start-up • Portable Exchange Deionizers (PEDI) and total water systems serviced by 700+ Culligan dealerships throughout North America • STULZ RO/DI by Culligan assures third party certification of industry standards and complete end-to-end

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    8 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us