Clock and Timer Panels Time-Of-Day Clock, General Clock - Timer Displays Elapsed Timer, Countdown Timer

Clock and Timer Panels Time-Of-Day Clock, General Clock - Timer Displays Elapsed Timer, Countdown Timer

Clock and Timer Panels Time-of-Day Clock, General Clock - Timer Displays Elapsed Timer, Countdown Timer Timer-Clock-Panel_D00207_00_D_XXEN/11.2014 BENDER Group Clock and Timer Panels Surgical Chronometer Time-of-Day Clock, Elapsed Timer, Countdown Timer General Clock - Timer Displays Application Clock and Timer systems are often used in medically used areas like operating theatres, intensive care units and even none medical area. Not only to display of the accurate time of day is very important in many applications but also the information of the elapsed time or a countdown time. In most applications the time of day is shown by an analogue clock whereas the timers are of digital type in all cases. To distinguish the digital displays between time of day, elapsed time and a countdown time the display colours are different in these multiple clock-timer applications. Description of the Time of Day Clocks The time of day clocks are of an analogue type in most cases but also extra bright digital Panel LED displays are being used. The clock display is being synchronized by a signal from a remote master clock. This can Characteristics either be a signal transmitted from a time server via LAN using the Network Time Protocol • Individual combinations of clocks and (NTP), a GPS signal via an antenna or in Europe the DCF77 signal. Simple synchronisation timers can also be achieved by using polarized DC impulses of an existing installation. An analogue clock can be synchronized simply by the 50 Hz Frequency of the supply voltage. The dial • Analogue or digital clock of the analogue clock is printed on a white background with black Arabic numbers. The • Various time synchronisation options e.g. size of the analogue dial is 165x165 mm. The digital clock can be set to a 12 hour or 24 hour display mode. The four digits are 57mm in height (HH:MM). On six digit displays the seconds – NTP network time protocol are 38 mm in height (HH:MM:SS). – GPS signal – radio controlled DCF77-signal Description of the Timers (in Europe only) The timers are running independent to a master clock since no synchronisation is required. The timers can be controlled by a simple timer remote control or by an alarm and control – polarized minutes DC impulse panel of the FM, TM or TCP series. The timers can be pre-set either as an elapsed timer or – stand-alone by the 50 Hz as a countdown timer. of the supply voltage Elapsed Timer: – MOBA line signal Start/Stop Resume Start the timer at 00:00 . • Digital timer for elapsed time or count- Stop will halt the timer and won’t continue in the background. down time Resume will activate the timer again. • Countdown time can be programmed to Interim Time/Reset Interim time will stop the timer display but the elapsed time will stop at zero Continue to count up. optional: to continue with elapsed time Reset will set the elapsed time back to 00:00 . • Optional: showing time interval (laps), The elapsed timer will count upwards in seconds up to 24hours. freeze timer or accumulating time intervals Countdown Timer: • Timer steps by seconds Start/Stop Resume Starts a countdown from a pre-set initial time down to 00:00. optional 1/100 sec or minutes Stop will halt the countdown and won’t continue in the Back ground. • 7-segment digital LED displays can easily Resume will activate the timer again. be read at a distance up to 25m Interim Time/Reset Interim time will stop the countdown display (laps) but the timer • Extra bright 57 mm digital red LED display, will continue to countdown. optional also in yellow, green or blue Reset will set the elapsed time back to a pre-set time. • Sensor controlled automatic or manual Setting initial time Pre-setting the initial time for a countdown. intensity control of the display The countdown will stop at 00:00 . • Individual enclosures for surface wall mounting or flush mounting with bezel Mechanical Design frame The clock and timer panels do come in various designs of front plates and enclosures. All panels are equipped with concealed hinges and the screw less front plates are covered • Surface with antibacterial front foil or by a unique life-long antibacterial foil surface or a 4mm thick safety glass plate for easy 4 mm glass cleaning. The standard background colour is silver matching the aluminium colour of the • Background of the surface in standard bezel frame and surface mounted enclosure. A wide variety of different background colours silver colour matching the enclosure or can optionally be chosen from. Two enclosures with a minimum depth of 90mm are its bezel frame available: • Many other background colours on request • Flush-mounting with aluminium bezel frame (UPB) The bezel frame made of anodised aluminium makes it possible to cover a gap between the flush-mounting housing and the wall of up to approx. 12 mm. It is possible to com- pensate for a height difference of up to 20 mm. • Surface mounted (AP) The anodised aluminium surface-mounting enclosure AP is suitable both for pure surface-mounting and also for partially recessed mounting. 2 Timer-Clock-Panel_D00207_00_D_XXEN/11.2014 Clock and Timer Panels Standard Configuration Table Single Display ( = standard configuration) Function Front Enclosure Control Display Face Sync. Standard Display Time of Foil UPB External via control panel Digital HH:MM NTP Dwg# 9800643 SS Day Clock Glass 483x300x100 Internal push button LED colour HH:MM: minute pulse mm (WxHxD) red Dial DC 12/24/48/60 V AP optional: 50 Hz Mode 450x260x60 yellow GPS, or DCF77 Time mm (WxHxD) green blue Analogue Dwg# 9800646 Elapsed Digital HH:MM - / - Timer LED colour HH:MM:SS 12 Countdown red 11 1 10 2 Timer 9 3 optional: 8 4 7 5 yellow 6 green blue Doppelanzeige ( = Standardkonfiguration) Function Front Enclosure Control Display Face Sync. Standard Display Time of Foil UPB External via control panel Digital HH:MM NTP Dwg# 9800644 SS Day Clock Glass 483x300x100 Internal push button LED colour HH:MM: minute pulse mm (WxHxD) red Dial DC 12/24/48/60 V AP optional: 50 Hz Mode 450x260x60 yellow GPS, or DCF77 Time mm (WxHxD) green blue Mode Time Analogue Elapsed Digital HH:MM - / - Timer LED colour HH:MM:SS Countdown red Timer optional: yellow green blue Dreifach Anzeige ( = Standardkonfiguration) Function Front Enclosure Control Display Face Sync. Standard Display Time of Foil UPB External via control panel Digital HH:MM NTP Dwg# 9800645 SS Day Clock Glass 483x300x100 Internal push button LED colour HH:MM: minute pulse mm (WxHxD) red Dial DC 12/24/48/60 V AP optional: 50 Hz 450x260x60 GPS, or DCF77 Mode yellow Time mm (WxHxD) green blue Mode Time Analogue Mode Elapsed Digital HH:MM - / - Time Timer LED colour HH:MM:SS Countdown red Timer optional: yellow green blue Elapsed Digital HH:MM - / - Timer LED colour HH:MM:SS Countdown red Timer optional: yellow green blue Timer-Clock-Panel_D00207_00_D_XXEN/11.2014 3 Clock and Timer Panels Typical Time Distribution Possible time distribution via Time over Ethernet (ToE) using the Network Time Protocol (NTP): DCF77 GPS Antenna Antenna LTS LTS Time Server Time Server NTP NTP NTP Mode Mode Time Time Time over NTP MoBa Line Ethernet NCI Network Interface DCF-Code (ToE) 12 12 11 1 11 1 10 2 10 2 9 3 NTP 9 3 8 4 8 4 7 5 7 5 6 NTP 6 NTP Firewall TCP Touch Control Panel Internet Time Server DWg# 9800655 Further ways of Time Distribution Supply of Clock and Timer Clock systems can be synchronized either by Time over Ethernet Single clocks and timers are being supplied by a 230 V/50 Hz voltage via the NTP protocol or optional via polarized minute DC impulses. or optional via a DC 24 V voltage. Only single clock displays may Systems with minute impulse are widely spread out in older optionally be supplied via the RJ45-Ethernet connection. In this installations. case an Power over Ethernet switch is mandatory from the Other ways of synchronisation are the MoBa line time signal or Ethernet side. the DCF-code transmission via an additional Network Clock Because a timer does not need an Ethernet connection, all double Interface (NCI). The simplest way of synchronisation is by using or triple clock and timer displays are generally utilized to accom- the 50 Hz frequency of the supply voltage. modate a 230 V/50 Hz supply or optional a DC 24 V supply. 4 Timer-Clock-Panel_D00207_00_D_XXEN/11.2014 Clock and Timer Panels Additional Clock Functions (Optional) Additional Timer Functions (Optional) Apart from the standard settings these functions can also be set Apart from the standard timer settings these functions can also be or chosen from: set or chosen from: • Time display in 12 or 24 hour cycle; four-digit (HH:MM) or six-di- • Upwards counting, starting from zero, up to 24 hours; git (HH:MM:SS) format. • Countdown from a set up value, with stop at zero or automatic Digits of the same height on request (HH:MM SS); optionally restart or counting to negative values; four-digit or six-digit format (including indication of the year); • Indication of interim times or “freezing“ of the display or accu- • Possibility of zero visualisation or suppression of the initial zero mulated interim time; when displaying the time and date; • Counting per one minute, one second or 1/100 second; • Display of the calendar date in four-digit or six-digit format • Control using the controller or remote control unit; including indication of the year. • Internal relay – possibility to adjust the time period of a closing • Temperature indication (providing the temperature sensor is relay contact in the time countdown mode when passing to zero connected) in °C or °F.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us