Leeza SOHO, Beijing, China Project Data

Leeza SOHO, Beijing, China Project Data

Studio London Leeza SOHO, Beijing, China 10 Bowling Green Lane London EC1R 0BQ Project Data T +44 20 7253 5147 F +44 20 7251 8322 [email protected] Project Start Date: October 2013 www.zaha-hadid.com Siteworks Start Date: April 2015 Completion Date: 19 November 2019 Structural Material: ‐ Below ground: • Foundation piles: concrete • Core, columns, beams and slabs: concrete - Above ground: • Core: Concrete • Columns: Steel, concrete infill • Beams : Steel • Trusses : Steel • Slabs : Composite, corrugated sheet with concrete topping • Helipad main structure : Steel Building function: ‐ Office tower with retail basement (B1,B2) ‐ Carpark on B2‐B4 ‐ Bicycle parking on B1 ‐ Subway cooling towers and public access to subway station. Height figures: ‐ Top of helipad: 207m ‐ Top of façade: 199.99m ‐ Top of core (parapet): 199.97m ‐ Top of core (FFL): 199.52m ‐ Top of atrium: 194.15m ‐ Top of roof (F46): 190.5m ‐ Standard floor to floor height: 4.1m ‐ Premium office floor (F45) floor to floor height: 5.7m Number of floors: ‐ 4 floors below ground, B1 to B4 ‐ 45 floors above ground, including 3 MEP floors on F13, 24, 35 Site area: ‐ 14.365 sqm Gross floor area: ‐ 124.000 sqm overground ‐ 48.800 sqm underground Elevator information: ‐ F1 – F45 : 16 Hitachi double deck system elevators, accessible from F1 and F2: o F1/F2 to F3 – F27 low zone elevators: ▪ 4 m/s ▪ 4 double deck elevators per tower – halve, 8 elevators with 16 cabins in total. o F1/F2 to F28 – F45 high zone elevators: Reg. VAT 0BQ. EC1R London Lane, Green Bowling Office:10 Registered 3749443. EnglandNo in Registered Architects. Hadid Zaha t/a ZahaLtd Hadid ▪ 6 m/s ▪ No. 4 double deck elevators per tower halve, 8 elevators with 16 cabins in total. 743 7288 09 7288 743 ‐ F2 – B4 : Retail and parking single cabin lift: ▪ 1.6 m/s ▪ 2 elevators per tower halve, 4 in total. ‐ B4 – F45 : Fire and goods lift: ▪ 1.6m/s ▪ 1 elevator per tower halve, 2 in total. Number of parking spaces: 480 Number of bicycle spaces: 2680 Sustainability: LEED pre Gold award in May 2019 Ventilation system/ fresh air: ‐ 30m3/hour/person ‐ PM 2.5 particle filtering .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us