Proposed Permananet Campus of at Village

Proposed Permananet Campus of at Village

For PROPOSED PERMANANET CAMPUS OF “IIT DHARWAD” [INSTITUTIONAL PROJECT] AT VILLAGE- KELAGIRI, CHIKKAMALLIGEWAD, DHARWAD DEVELOPED BY M/s INDIAN INSTITUTE OF TECHNOLOGY, DHARWAD, KARNATAKA Proposed Permanent Campus of IIT Dharwad M/s IIT Dharwad (Institutional Project) At Kelagiri, Chikkamalligewad, Dharwad, Karnataka Contents Introduction ........................................................................................................................... 4 General .............................................................................................................................. 4 Project Location and Connectivity ............................................................................................ 4 Land Environment ................................................................................................................. 7 Topography ........................................................................................................................ 7 Area Details ....................................................................................................................... 8 Building Components of site ................................................................................................. 8 Population Density ................................................................................................................11 During the Construction Phase ...........................................................................................11 During Operational Phase ..................................................................................................11 Water Environment ...............................................................................................................12 Hydrology .........................................................................................................................12 Drainage ...........................................................................................................................14 Freshwater demand and source ...........................................................................................16 Construction Phase.........................................................................................................16 Operational Phase ..........................................................................................................17 During Construction Phase .............................................................................................19 During Operational Phase ..............................................................................................19 Parking Details......................................................................................................................24 Rainwater Harvesting and Storm Water Drain ........................................................................24 Need for Rainwater Harvesting ...........................................................................................24 Power Requirement ................................................................................................................26 Energy Conservation Measures ...............................................................................................27 Solid Waste Generation .........................................................................................................29 During Operational Phase ..................................................................................................29 Collection and Segregation of waste .....................................................................................30 Treatment of Waste ...........................................................................................................31 Organic Waste Converter ....................................................................................................31 Technique for disposal of biodegradable waste ......................................................................31 Disposal ............................................................................................................................33 Conceptual Plan Page | 2 Proposed Permanent Campus of IIT Dharwad M/s IIT Dharwad (Institutional Project) At Kelagiri, Chikkamalligewad, Dharwad, Karnataka Landscape details ...................................................................................................................34 List of building materials being used at site ..............................................................................36 List of Machinery Used During Construction ...........................................................................37 Figure 1-Project location showing site coordinates ...................................................................... 5 Figure 2- site and Its surroundings ........................................................................................... 6 Figure 3- Hydrology map of District Dharwad Dikstrict ...........................................................14 Figure 4- Drainage Map of Dharwad District ..........................................................................16 Figure 5- Water balance diagram ............................................................................................19 Figure 6-Process and Instrumentation of STP technology ..........................................................23 Figure 7-Waste Management-Construction Phase ....................................................................29 Figure 8-Organic Waste Convertor ..........................................................................................33 Figure 9: Solid Waste Management Scheme -Domestic Waste ...................................................34 Table 1-Geographical co-ordinates of the site ............................................................................. 4 Table 2- Building Components of all the phases ......................................................................... 8 Table 3- Area Details .............................................................................................................11 Table 4-Population details for proposed area ............................................................................12 Table 5-water demand during construction phase ................................................................17 Table 6-water conservation measure ........................................................................................17 Table 7-Water demand for the operational phase ......................................................................18 Table 8- Wastewater calculation with respect to STP ................................................................18 Table 9- Summary of recycled and reused water .......................................................................18 Table 10-Wastewater Details ..................................................................................................20 Table 11- Total Parking Proposed ...........................................................................................24 Table 12-Calculation for Storm water load ..............................................................................26 Table 13-Electrical Load Details .............................................................................................26 Table 14-Energy Conservation by Solar PV .............................................................................28 Table 15: Calculation of Solid Waste Generation .....................................................................30 Table 16-Optimum condition for composting ...........................................................................32 Table 17-Characterstic of Final Compost .................................................................................32 Table 18-Landscape area details .............................................................................................35 Table 19-List of Plantation Proposed .......................................................................................36 Conceptual Plan Page | 3 Proposed Permanent Campus of IIT Dharwad M/s IIT Dharwad (Institutional Project) At Kelagiri, Chikkamalligewad, Dharwad, Karnataka Introduction General As per EIA Notification, 2006 & its amendments, all building construction and area development projects comes under schedule 8 and are required to obtain prior environmental clearance from State Environmental Impact Assessment Authority (SEIAA)/MoEF&CC. For the category 8(b), application seeking prior environmental clearance shall be made in the prescribed Form 1 with proposed ToR annexed herewith and supplementary Form 1A and Conceptual Plan in SEIAA/MoEF&CC. The project shall be screened and scrutinized by respective SEAC/EAC. Following the appraisal of the project to the satisfaction of the SEAC/ SEIAA/MoEF&CC, Environmental Clearance shall be granted. Since, the total plot area of the project is greater than 50 hectares, it is categorized as 8(b) project, under the EIA Notification, 2006 and requires environmental clearance from the SEIAA, Karnataka. About project Indian Institute of Technology Dharwad (IIT Dharwad) is an autonomous premier engineering and technology university in Dharwad, India. The Indian Institute of Technology (IIT) at Dharwad started functioning from July 2016 in a temporary campus, previously of the Water and Land Management Institute (WALMI) in Belur village on the outskirts of Dharwad city. It was

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    37 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us