LF RELAYS Ideal for Compressor and Inverter Loads, 1 Form a 20 A, Power Relays

LF RELAYS Ideal for Compressor and Inverter Loads, 1 Form a 20 A, Power Relays

Power relays (Over 2 A) LF RELAYS Ideal for compressor and inverter loads, 1 Form A 20 A, Power relays Protective construction:Flux-resistant type FEATURES Ideal for compressor and inverter loads Insulation distance (between contact and coil): Clearance Min. 8 mm and Creepage Min. 9.5 mm Surge withstand voltage: 10,000 V 15.7 30.1 15.7 30.1 TMP type/PCB type 23.3 23.3 TYPICAL APPLICATIONS Air conditioner Refrigerators TMP type PCB type OA equipment (Unit:mm) ORDERING INFORMATION (PART NO.) ALF 1 Contact arrangement Terminal shape Rated coil voltage(DC) 1 Form A T:TMP type 05:5V, 06:6V, 09:9V P:PCB type 12:12V, 18:18V, 24:24V Note:Certified by UL/C-UL,VDE and TÜV TYPES Part No. Standard packing Contact arrangement Rated coil voltage TMP type PCB type Inner carton Outer carton 5 V DC ALF1T05 ALF1P05 6 V DC ALF1T06 ALF1P06 9 V DC ALF1T09 ALF1P09 1 Form A 50 pcs. 200 pcs. 12 V DC ALF1T12 ALF1P12 18 V DC ALF1T18 ALF1P18 24 V DC ALF1T24 ALF1P24 2021.05 industrial.panasonic.com/ac/e/ ー 1 ー Panasonic Corporation 2021 ASCTB195E 202105 Power relays (Over 2 A) LF RELAYS RATING Coil data • Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc. Therefore, please use the relay within ±5% of rated coil voltage. • ‘Initial’ means the condition of products at the time of delivery. Rated operating Max. allowable Rated coil Operate voltage* Release voltage* Coil resistance Rated operating current voltage voltage (at 20°C) (at 20°C) (±10%, at 20°C) power (±10%, at 20°C) (at 60°C) 5 V DC 180 mA 27.8 Ω 6 V DC 150 mA 40 Ω Max. 70% V of Min. 10% V of 9 V DC 100 mA 90 Ω 110% V of rated rated coil voltage rated coil voltage 900 mW coil voltage 12 V DC (Initial) (Initial) 75 mA 160 Ω 18 V DC 50 mA 360 Ω 24 V DC 37.5 mA 640 Ω *square, pulse drive Specifications Item Specifications Contact arrangement 1 Form A Contact resistance Max. 100 mΩ (by voltage drop 6 V DC 1 A) (initial) Contact material AgSnO2 type Contact rating 20 A 250 V AC (resistive) Contact data Max. switching power 6,250 VA (resistive) Max. switching voltage 250 V AC Max. switching current 25 A (AC) Min. switching load 100 mA 5 V DC (reference value)*1 Insulation resistance (initial) Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) Between open contacts 1,000 Vrms for 1 min (detection current: 10 mA) Dielectric strength (initial) Between contact and 5,000 Vrms for 1 min (detection current: 10 mA) coil Surge withstand Between contact and 10,000 V voltage (initial)*2 coil Time Operate time Max. 20 ms at rated coil voltage (at 20°C, without bounce) characteristics (initial) Release time Max. 15 ms at rated coil voltage (at 20°C, without bounce, with diode) 2 Shock Functional 100 m/s (half-sine shock pulse: 11 ms, detection time: 10 μs) resistance Destructive 1,000 m/s2 (half-sine shock pulse: 6 ms) Vibration Functional 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs) resistance Destructive 10 to 55 Hz (at double amplitude of 1.5 mm) Expected life Mechanical life Min. 2 x 106 (switching frequency: 180 times/min) Conditions for usage, Conditions Ambient temperature: -40 to +60°C, Humidity: 5 to 85% RH (Avoid icing and condensation) transport and storage*3 Unit weight Approx. 23 g *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50 μs according to JEC-212-1981 *3. For ambient temperature, please read “GUIDELINES FOR RELAY USAGE”. Expected electrical life Conditions: at 20°C Type Load Switching capacity Number of operations 20 A 250 V AC (cosφ = 1.0) Min. 100 x 103 (switching frequency 20 times/min) Resistive load 25 A 250 V AC (cosφ = 1.0) Min. 10 x 103 (switching frequency 20 times/min) Inrush 70 A (cosφ = 0.7), Steady 20 A (cosφ = 0.9) Compressor load Min. 100 x 103 (switching frequency 20 times/min) 250 V AC 1 Form A Inrush 200 A, Steady 20 A Min. 30 x 103 (switching frequency 10 times/min) 100 V AC Inverter load Inrush 100 A, Steady 10 A Min. 30 x 103 (switching frequency 10 times/min) 200 V AC Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 2 ー Panasonic Corporation 2021 ASCTB195E 202105 Power relays (Over 2 A) LF RELAYS REFERENCE DATA 1.Switching life curve 2.Coil temperature characteristics (Average) Tested sample:ALF1T12, 6 pcs. Measured portion:Coil inside Contact current : 20A Ambient temperature : 25℃, 60℃ 1,000 70 500 ) 60 ℃ 4 25 10 (℃) 50 60℃ (× 100 50 125V AC resistive load 40 30 250V AC resistive load Temperature rise No.of operations No.of 10 20 5 10 0 0 10 20 30 800 100 120 Contact current(A) Coil applied voltage(%V) 3-1.200 V AC Electrical life test (200 V AC Inverter load) Tested sample:ALF1T12, 6 pcs. Change of operate and release voltage Load:Inrush 102A(wave peak value), Steady 14.4A(wave peak value) 12 Contact welding:0times Inverter dummy 200V AC ) V Miscontact:0times Operation frequency:ON:OFF=1s:5s Circuit: ( 10 Operate voltage Max.Max. 8 Ave.Ave. Min.Min. LF relay contact 6 Release voltage Max. 200V AC 2,000μF 4 Ave.Ave. 1.9Ω Min. Operate and release voltage release and Operate 2 Switch 0 0 3 6 No. of operations(×104) 3-2.100 V AC Electrical life test (100 V AC Inverter load) Tested sample:ALF1T12, 6 pcs. Change of operate and release voltage Load : Inrush 224A(wave peak value), Steady 30.5A(wave peak value) 12 Contact welding:0times Inverter dummy 100V AC ) V : Operation frequency:ON:OFF=1s:5s Miscontact 0times Circuit : ( 10 Operate voltage 8 Max.Max. Ave.Ave. 470μF LF relay contact 6 Min.Min. Release voltage 2,000μF Max. 100V AC 4 Ave.Ave. 470μF Min. Operate and release voltage release and Operate 2 0 0 3 6 No. of operations(×104) Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 3 ー Panasonic Corporation 2021 ASCTB195E 202105 Power relays (Over 2 A) LF RELAYS 3-3.250 V AC Electrical life test (250 V AC Compressor dummy load) 3-4. Electrical life test (20 A 250 V AC Resistive load) Tested sample:ALF1T12, 6 pcs. Tested sample:ALF1T12, 6 pcs. Load: Inrush 70.7A, cosφ=0.7 Change of operate and release voltage Operation frequency:ON:OFF=1.5s:1.5s 20 φ 0 9 Steady A, cos = . 12 12 compressor dummy 250V AC Contact welding:0times : ) Contact welding 0times : : : ) Operation frequency ON OFF=1.5s 1.5s V Miscontact:0times V Miscontact:0times : ( Circuit 10 ( 10 Operate voltage 8 8 Max.Max. Ave.Ave. Operate voltage Max.Max. 6 Ave.Ave. 6 Min.Min. Min.Min. Release voltage Max. 4 Release voltage Max. 4 Ave.Ave. Ave.Ave. Min. Operate and release voltage release and Operate Min. Operate and release voltage release and Operate 2 2 0 0 0 5 10 0 10 20 No. of operations(×104) No. of operations(×104) DIMENSIONS CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website. Unit: mm TMP type CAD External dimensions Schematic 11.25 12.8 (BOTTOM VIEW) 0.8 0.8 #250 terminal 6.4 FASTON #250 9 . 2 . 7 2 10 PC board side 3 . 23 5 . Recommended PC board pattern 0 (BOTTOM VIEW) 4 27.6 0.8 0.8 1.6 0.3 2dia. 13.8 2dia. 1.6 1.6 12 22 27.6 30.1 12 1.8dia. 12 10 1.8dia. 7 General tolerance . Less than 1mm:±0.1 Tolerance ±0.1 15 Min. 1mm less than 3mm:±0.2 Min. 3mm:±0.3 PCB type CAD External dimensions Schematic (BOTTOM VIEW) 3 . 23 5 . 0 Recommended PC board pattern 4 (BOTTOM VIEW) 0.8 0.8 1.6 0.3 1.6 1.6 12 27.6 22 2dia. 13.8 2dia. 27.6 30.1 12 7 General tolerance 1.8dia. 1.8dia. 12 10 Less than 1mm:±0.1 15 Min. 1mm less than 3mm:±0.2 Tolerance ±0.1 Min. 3mm:±0.3 Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 4 ー Panasonic Corporation 2021 ASCTB195E 202105 Power relays (Over 2 A) LF RELAYS SAFETY STANDARDS Each standard may be updated at any time, so please check our Website for the latest information. UL/C-UL (Recognized) CSA (Certified) Ambient CSA standard certified by C-UL File No. Contact rating Operations temperature 25 A 277 V AC Resistive 6 × 103 40°C E43028 20 A 277 V AC Resistive 100 × 103 40°C VDE (Certified) TÜV (Certified) Ambient Ambient File No. Contact rating Operations File No. Contact rating Operations temperature temperature 20 A 250 V AC (cosφ = 1.0) 10 × 103 60°C 20 A 250 V AC 40009169 B 18 03 13461 374 10 × 103 60°C 10 A 250 V AC (cosφ = 0.4) 100 × 103 70°C (cosφ = 1.0) TV rating File No.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    8 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us