Appendix B: HVAC Systems and Indoor Air Quality

Appendix B: HVAC Systems and Indoor Air Quality

Appendix B: HVAC Systems and Indoor Air Quality This appendix provides information ■ age of the design about specific HVAC system designs and ■ climate components in relation to indoor air ■ building codes in effect at the time of quality. It also serves as introductory the design material for building owners and managers ■ budget that was available for the project who may be unfamiliar with the terminol- ■ planned use of the building ogy and concepts associated with HVAC ■ owners’ and designers’ individual (heating, ventilating, and air conditioning) preferences system design. Further detailed informa- ■ subsequent modifications tion can be found in ASHRAE manuals HVAC systems range in complexity and guides and in some of the guidance from stand-alone units that serve developed by other trade and professional individual rooms to large, centrally associations. (See Guidelines of Care controlled systems serving multiple zones Developed by Trade Associations in in a building. In large modern office Section 5.) Additional information can be buildings with heat gains from lighting, obtained using Appendix G or through people, and equipment, interior spaces discussion with your facility engineer. often require year-round cooling. Rooms at the perimeter of the same building (i.e., BACKGROUND rooms with exterior walls, floors, or roof All occupied buildings require a supply of surfaces) may need to be heated and/or Working with the electrical components of an HVAC outdoor air. Depending on outdoor cooled as hourly or daily outdoor weather system involves the risk of conditions, the air may need to be heated conditions change. In buildings over one electrocution and fire. A or cooled before it is distributed into the story in height, perimeter areas at the lower knowledgeable member of the building staff should occupied space. As outdoor air is drawn levels also tend to experience the greatest oversee the inspection of the into the building, indoor air is exhausted or uncontrolled air infiltration. HVAC controls. allowed to escape (passive relief), thus removing air contaminants. The term “HVAC system” is used to refer to the equipment that can provide heating, cooling, filtered outdoor air, and humidity control to maintain comfort conditions in a building. Not all HVAC systems are designed to accomplish all of these functions. Some buildings rely on only natural ventilation. Others lack mechanical cooling equipment (AC), and many function with little or no humidity control. The features of the HVAC system in a given building will depend on several variables, including: HVAC Systems and Indoor Air Quality 121 Some buildings use only natural complains that it is too cold or too hot and ventilation or exhaust fans to remove odors the observed (measured) conditions are and contaminants. In these buildings, outside of the ASHRAE comfort zone, thermal discomfort and unacceptable then the HVAC system needs to be indoor air quality are particularly likely evaluated. Sometimes the problem can be when occupants keep the windows closed relieved by fine tuning or repairing the because of extreme hot or cold tempera- HVAC system, but in some cases the tures. Problems related to underventilation system cannot perform as expected, and a are also likely when infiltration forces are long-term solution must be investigated. weakest (i.e., during the “swing seasons” and summer months). TYPES OF HVAC SYSTEMS Modern public and commercial build- Single Zone ings generally use mechanical ventilation systems to introduce outdoor air during the A single air handling unit can only serve occupied mode. Thermal comfort is more than one building area if the areas commonly maintained by mechanically served have similar heating, cooling, and distributing conditioned (heated or cooled) ventilation requirements, or if the control air throughout the building. In some system compensates for differences in designs, air systems are supplemented by heating, cooling, and ventilation needs piping systems that carry steam or water to among the spaces served. Areas regulated the building perimeter zones. As this by a common control (e.g., a single document is concerned with HVAC thermostat) are referred to as zones. systems in relation to indoor air quality, Thermal comfort problems can result if the the remainder of this discussion will focus design does not adequately account for on systems that distribute conditioned air differences in heating and cooling loads to maintain occupant comfort. between rooms that are in the same zone. This can easily occur if: Roles of the HVAC System Operator ■ The cooling load in some area(s) with- and Facility Manager in a zone changes due to an increased The system operator(s) and facility occupant population, increased lighting, manager(s) (or IAQ manager) are among or the introduction of new heat-produc- the most significant factors in determining ing equipment (e.g., computers, copiers). whether IAQ problems will occur in a ■ Areas within a zone have different solar properly designed, constructed, and exposures. This can produce radiant heat commissioned HVAC system. HVAC gains and losses that, in turn, create systems require preventive maintenance and unevenly distributed heating or cooling prompt repairs if they are to operate needs (e.g., as the sun angle changes correctly and provide comfortable condi- daily and seasonally). tions. The operator(s) must have an adequate understanding of the overall Multiple Zone system design and its limitations. The Multiple zone systems can provide each HVAC system capacity and distribution zone with air at a different temperature by characteristics should be evaluated before heating or cooling the airstream in each renovations to the building, changes in its zone. Alternative design strategies involve occupancy, or changes in the use of an area. delivering air at a constant temperature System operators must be able to while varying the volume of airflow, or respond appropriately to occupant com- modulating room temperature with a plaints. For example, if an occupant 122 Appendix B supplementary system (e.g., perimeter hot water piping). TESTING AND BALANCING Constant Volume Modern HVAC systems typically use sophisticated, automatic controls to Constant volume systems, as their name supply the proper amounts of air for heating, cooling, and ventilation in commercial buildings. Problems during installation, operation, mainte- suggests, generally deliver a constant nance, and servicing the HVAC system could prevent it from operating as airflow to each space. Changes in space designed. Each system should be tested to ensure its initial and contin- temperatures are made by heating or ued performance. In addition to providing acceptable thermal conditions cooling the air or switching the air han- and ventilation air, a properly adjusted and balanced system can also reduce operating costs and increase equipment life. dling unit on and off, not by modulating Testing and balancing involves the testing, adjusting, and balancing of the volume of air supplied. These systems HVAC system components so that the entire system provides airflows that often operate with a fixed minimum are in accordance with the design specifications. Typical components and system parameters tested include: percentage of outdoor air or with an “air economizer” feature (described in the ■ all supply, return, exhaust, and outdoor airflow rates ■ Outdoor Air Control discussion that control settings and operation ■ air temperatures follows). ■ fan speeds and power consumption Variable Air Volume ■ filter or collector resistance Variable air volume systems maintain The typical test and balance agency or contractor coordinates with the thermal comfort by varying the amount of control contractor to accomplish three goals: verify and ensure the most heated or cooled air delivered to each effective system operation within the design specifications, identify and correct any problems, and ensure the safety of the system. space, rather than by changing the air A test and balance report should provide a complete record of the temperature. (However, many VAV design, preliminary measurements, and final test data. The report should systems also have provisions for resetting include any discrepancies between the test data and the design specifica- tions, along with reasons for those discrepancies. To facilitate future the temperature of the delivery air on a performance checks and adjustments, appropriate records should be kept seasonal basis, depending on the severity on all damper positions, equipment capacities, control types and loca- of the weather). Overcooling or tions, control settings and operating logic, airflow rates, static pressures, fan speeds, and horsepowers. overheating can occur within a given zone Testing and balancing of existing building systems should be per- if the system is not adjusted to respond to formed whenever there is reason to believe the system is not functioning the load. Underventilation frequently as designed or when current records do not accurately reflect the actual occurs if the system is not arranged to operation of the system. The Associated Air Balance Council recom- mends the following guidelines in determining whether testing and introduce at least a minimum quantity (as balancing is required: opposed to percentage) of outdoor air as ■ When space has been renovated or changed to provide for new occu- the VAV system throttles back from full pancy. airflow, or if the system supply air ■ When HVAC

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    19 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us