Reclosers and Controls Reclosers and Controls Catalog Information Reclosers and Controls Catalog Technical Data Effective August 2014 

Reclosers and Controls Reclosers and Controls Catalog Information Reclosers and Controls Catalog Technical Data Effective August 2014 

Eaton’s Cooper Power Systems catalog Reclosers and controls Reclosers and controls Catalog information Reclosers and controls catalog Technical Data Effective August 2014 Reclosers and controls catalog contents Contents Description Page Smart single-phase automation and protection solutions (B280-13004) .................. 3 General ratings information and catalog guide for single-phase and three-phase reclosers (280-05) ................................................. 5 Types E, 4E, V4E, H, 4H, V4H, L, V4L, single-phase and 6H, V6H threephase reclosers (280-10) ................................................. 21 Types D and DV single-phase hydraulically controlled recloser (280-20) ................. 33 Types W, WV27, WV38X, VW, VWV27, and VWV38X, three-phase hydraulically controlled reclosers (280-30) ........................................ 41 Types VWE, VWVE37, VWVE38X, WE, WVE27, and WVE38X, three-phase electronically controlled reclosers (280-40) ............................. 65 NOVA15, NOVA27, and NOVA38 three-phase, microprocessorcontrolled recloser (280-42) ...................................... 81 Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser (280-45) ................... 93 Type VSO three-phase electronically controlled recloser (280-57) ..................... 105 MET electronic recloser control tester (280-76) .................................. 121 SPEAR™ single-phase recloser system (280-101) ................................ 123 Form 4D microprocessor-based recloser control and accessories (280-104) ............ 143 www.cooperpower.com SPEAR™ Single-Phase Recloser System Smart single-phase automation and protection solutions With full system protection, Improve customer reliability Reduce maintenance costs Utilizing field-proven and lower total life-cycle costs recloser technology and the SPEAR recloser system SPEAR recloser technology is perfect for multiple grid The SPEAR recloser design is provides durable service and based on field-proven NOVA™ reliability: the industry leading applications, up to 38 kV. recloser technology. The • Solid Outdoor Cycloaliphatic ProView™ NXG encapsulated axial-magnetic Epoxy—no gas, oil, or foam to platform, the SPEAR™ vacuum interrupter, and a check and maintain, and no lightweight, solid cycloaliphatic- noxious by-products to dispose epoxy design make the SPEAR single-phase recloser recloser a durable and flexible • Vacuum Interruption with Axial- and control hosts a single-phase choice for Magnetic Field—extended demanding application contact and mechanical life complete set of requirements. • Magnetic-Actuator Operated protection, automation, Environmentally preferred Mechanism—low power mechanism provides reliable metering, and data Using Cooper Power Systems™ operation, year after year NOVA solid-insulation system, acquisition functionality SPEAR reclosers are designed and manufactured to be SF6 to maximize system gas-free and oil-free. NOVA solid performance and reduce insulation eliminates the need for insulating gas or liquid; customer outages. thereby, greatly reducing the recloser life-cycle maintenance costs, and reducing user’s environmental concerns. Reduce installation time The SPEAR recloser, with its compact size and narrow profile, simplifies pole installation which reduces total installation time. Operators can be confident with handle, indicator and control functions being similar in look and feel to decades of installed electronic reclosers from Cooper Power Systems. B280-13004-1 Adding intelligent SPEAR single-phase Protection flexibility Data acquisition recloser control The two separate protection To prevent future outages and single-phase Cooper The new microprocessor-based profiles include: improve grid performance, Power Systems SPEAR SPEAR recloser control numerous data acquisition integrates real-time valuable grid • Overcurrent protection features are standard: reclosers and controls and outage data to be ported to including 54 standard time- current curves available • Data Profiler, user configurable to distribution lines can your SCADA or feeder with memory of 21 days for automation system. Complete • Time current curve modi- 10 analogs meet today's system with a separate regulated power fiers—including minimum supply, the control is response time adder • Event Recorder with a reliability needs and automation-ready for your choice 1000 event memory of radio. Also, tailor your digital • High-current trip and high- easily transition for communications performance current lockout sequence Receive real-time system data: with the user- configurable coordination future Smart Grid • Metering mapping of protocol DNP3. The • Cold load pickup applications. control can be easily configured • Sequence of events through the simple front panel • Hot-line tag • Data profiler display or with a laptop through • Fast trip disabled a USB port on the front panel. • Active control data • Reclose retry • Smart Grid ready • Recloser status Metering data • Improve customer reliability • Hot-line tag The SPEAR recloser control has • Lower total life-cycle costs • Non-reclosing instantaneous and demand • Easy operation metering with programmable • Alternate profile integration intervals for system • Greater application flexibility • loading and planning: Battery test voltage and current • Full metering • Demand power • Data acquisition • Demand current • Remote monitoring • Instantaneous current and • Simple, intuitive programming voltage • Common look and feel to • Energy and power factor other Cooper Power Systems controls • Frequency • CBC-8000 capacitor control • Power metering • F4D recloser control • CL-7 regulator control Table 1. SPEAR Ratings Voltage - kV Continuous - A Interrupting - kA BIL - kV 400 8 630 110 15 12.5 800 400 8 27 630 125 12.5 800 400 8 38 630 170 12.5 800 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Power Systems Business 2300 Badger Drive Waukesha, WI 53188 Eaton, Cooper Power Systems, SPEAR, United States NOVA, and ProView are valuable trademarks CooperPower.com of Eaton in the U.S. and other countries. You are not permitted to use the © 2013 Eaton Eaton Trademarks without the prior written All Rights Reserved consent of Eaton. Printed in USA Publication No. B280-13004 All other trademarks are property August 2013 of their respective owners. B280-13004-1 Effective August 2013 Technical Data 280-05 Supersedes October 2012 General ratings information and catalog guide for single-phase and three-phase reclosers Contents Description Page Description Page Description .............................. 2 Interrupting medium: oil or vacuum ........... 5 Temporary faults .......................... 2 Oil interrupters .......................... 5 Recloser classifying features ................. 2 Vacuum interrupters ...................... 5 Recloser: single-phase or three-phase ......... 2 Recloser application. 5 Single-phase reclosers .................... 2 Application criteria ....................... 5 Three-phase reclosers .................... 2 Coordination with other devices ............. 6 Recloser ratings summary. ................. 3 Dual timing ............................. 6 Single-phase tripping .................... 4 Distribution circuit with reclosers diagram ..... 6 Three-phase tripping .................... 4 Recloser operating sequence of fault ......... 7 Controls: hydraulic or electronic .............. 4 Ratings Tables Hydraulic controls ........................ 4 Ratings for single-phase, hydraulically controlled Electronic controls. ....................... 4 reclosers ............................... 7 Current sensing ......................... 4 Ratings for single-phase, electronically controlled reclosers ............................... 9 Microprocessor-based controls ............. 4 Ratings for three-phase, hydraulically controlled reclosers .............................. 10 Ratings three-phase, electronically controlled reclosers .............................. 13 280-05-1 Technical Data 280-05 General ratings and catalog guide for single-and Effective August 2013 three-phase reclosers Description Recloser: single-phase or three-phase Automatic circuit reclosers are recognized by electric utilities Both single- and three-phase reclosers are available to satisfy throughout the world as an essential device for achieving their application requirements. prime goal: providing maximum continuity of electric service to their customers simply and economically. Single-phase reclosers Reclosers sense and interrupt fault currents and automatically Single-phase reclosers, as shown in Figure 1 and 2, are used to restore service after momentary outage. protect single-phase lines such as branches or taps of a three-phase The automatic circuit recloser is essentially a self-contained device feeder. They can also be used on three-phase circuits where the load with the necessary intelligence to sense overcurrents to time and is predominantly single-phase. Thus, when a permanent phase-to- interrupt fault currents and to re-energize the line by reclosing ground fault occurs, one phase can be locked-out while service is automatically. If a fault is permanent, the recloser locks open after maintained to the remaining two-thirds of the system. a preset number of operations (usually three or four), isolating the faulted section from the main part of the system. Three-phase reclosers Two types of three-phase reclosers are available: Temporary faults • Single-Phase

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    159 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us