Research Article Propofol versus fl unitrazepam for inducing and maintaining sleep in postoperative ICU patients Cornelius Engelmann, Jan Wallenborn1, Derk Olthoff2, Udo X. Kaisers2, Henrik Rüffert3 Context: Sleep deprivation is a common problem on intensive care units (ICUs) Access this article online infl uencing not only cognition, but also cellular functions. An appropriate sleep-wake cycle Website: www.ijccm.org should therefore be maintained to improve patients’ outcome. Multiple disruptive factors DOI: 10.4103/0972-5229.130572 on ICUs necessitate the administration of sedating and sleep-promoting drugs for patients Quick Response Code: Abstract who are not analgo-sedated. Aims: The objective of the present study was to evaluate sleep quantity and sleep quality in ICU patients receiving either propofol or fl unitrazepam. Settings and Design: Monocentric, randomized, double-blinded trial. Materials and Methods: A total of 66 ICU patients were enrolled in the study (fl unitrazepam n = 32, propofol n = 34). Propofol was injected continuously (2 mg/kg/h), fl unitrazepam as a bolus dose (0.015 mg/kg). Differences between groups were evaluated using a standardized sleep diary and the bispectral index (BIS). Statistical Analysis Used: Group comparisons were performed by Mann-Whitney U-Test. P < 0.05 was considered to be statistically signifi cant. Results: Sleep quality and the frequency of awakenings were signifi cantly better in the propofol group (Pg). In the same group lower BIS values were recorded (median BIS propofol 74.05, fl unitrazepam 78.7 [P = 0.016]). BIS values had to be classifi ed predominantly to slow-wave sleep under propofol and light sleep after administration of fl unitrazepam. Sleep quality improved in the Pg with decreasing frequency of awakenings and in the fl unitrazepam group with increasing sleep duration. Conclusions: Continuous low-dose injection of propofol for promoting and maintaining night sleep in ICU patients who are not analgo-sedated was superior to fl unitrazepam regarding sleep quality and sleep structure. Keywords: Bispectral index, intensive care unit, propofol, sleep Introduction on intensive care units (ICU), the administration of sedatives is necessary in most cases to promote night Defi cient quality, duration and structure of sleep may sleep. The most widely used drugs are benzodiazepines have a detrimental effect on the recovery of intensive like the long-acting fl unitrazepam. In general, they tend care patients.[1-5] Maintaining an adequate sleep-wake cycle with a suffi cient night sleep is therefore crucial to prolong sleep duration without improving sleep [6] for these patients. Due to various disrupting factors quality. For anesthetics, many studies have documented a From: sleep-like state by activation or inhibition of different brain Departments of Gastroenterology, Rheumatology and Hepatology, and regions.[7-10] Anesthesia in general and propofol in particular 2Anaesthesiology and Intensive Care Medicine, University Hospital Leipzig [11,12] Liebigstrasse 20, 04103 Leipzig, 1Department of Anaesthesiology and seem to reverse the effects of sleep deprivation and Intensive Care Medicine, Helios Klinikum Aue, Gartenstraße 6, 08280 Aue, show sleep-like electroencephalographic patterns. 3Department of Anaesthesiology, Intensive Care Medicine, Pain Therapy [13-15] and Palliative Care, Helios Klinikum Borna, Rudolf-Virchow-Straße 2, 04552 However evidence of improved sleep quality for Borna, Germany ICU-patients is still lacking.[16] Correspondence: Dr. Cornelius Engelmann, Department of Gastroenterology, Rheumatology and Hepatology, University Hospital Leipzig, Liebigstrasse 20, 04103 Leipzig, The objective of this study was to determine the Germany. E-mail: [email protected] quality and quantity of night sleep in spontaneously 212 Indian Journal of Critical Care Medicine April 2014 Vol 18 Issue 4 breathing ICU patients under two different sedation MA, USA). The high and low fi lters were set to 70 Hz regimes with propofol and fl unitrazepam. Sleep duration and 0.25 Hz. The notch fi lter was set to 50 Hz. Four and sleep quality were evaluated using a modified electrodes (BIS-Sensor XP Quatro, Aspect Medical “Pittsburgh sleep diary (PghSD)”[17] and by simplifi ed Systems, Natick, MA, USA) were placed on the forehead electroencephalogram (EEG) monitoring with the according to the recommendations of Aspect Medical bispectral index (BIS). Systems, three of them on the frontal scalp (electrode one center position 1 cm above the nose, electrode Materials and Methods four above the eyebrow) and one on the temporal scalp (electrode three between the eye and hairline). Study design The electrodes were connected through the wire and The prospective randomized double-blinded study digital signal converter to the monitor. was approved by the local ethics committee and has therefore been performed in accordance with the ethical Depending on the signal quality index (SQI), the standards laid down in the 1964 Declaration of Helsinki degree of influences of artefacts (“proportion of and its later amendments. Written informed consent satisfying measurements”), the suppression ratio, the was obtained from each participant. Only patients electromyogram, the BIS and the SQI were displayed without pre-existing sedation, mechanical ventilation, on the monitor. All parameters were recorded as 5 s hepatic diseases, renal insuffi ciency or cerebral diseases average-values. who were admitted after surgical intervention to anesthesiological ICU were eligible for this study. As Sleep diary environmental noise is a considerable factor infl uencing Patients were asked to assess their sleep quality using patients’ sleep in ICU medical interventions and a standardized sleep diary [amended version of the sounds were reduced to a minimum according to clinic PghSD].[17] This was carried out in the afternoon of the standards and documented by the nursing staff. fi rst “post-interventional” day, when the patients were fully conscious. Patients were asked to give information After randomization patients were prepared by on the point of time of falling asleep, the duration of fi xing the BIS electrodes to the skin, connecting the BIS sleep, the number and duration of awakenings and the monitor to a laptop and monitoring vital signs such as length of time spent awake. Furthermore, sleep quality, oxygen saturation, blood pressure and heart rate. Heart quality of falling asleep, regeneration and refreshment rate (bpm) and capillary oxygen saturation (%) were after sleep had to be assessed. The evaluation was done recorded continuously. Depending on the availability by using school grade-like numbers between one and of equipment, blood pressure was measured either five. Number one was consistent with “very good” invasively and continuously or non-invasively and quality and fi ve with “very bad” quality. intermittently (every 15 min). Data were collected over a period of 7 h from 11 pm to 6 am. Statistical analysis Data were analyzed using the IBM SPSS Statistics 11.5 For comparability, we chose the intravenous route for for Windows. Group comparisons were performed by fl unitrazepam since propofol can only be administered Mann-Whitney U-Test. A P < 0.05 was considered as parenterally. The drugs were injected after a period of statistically signifi cant. Values for epidemiological data 2 min at rest. Propofol (20 mg/ml) was administered were represented as mean ± SD and for non-parametric continuously with 2 mg/kg/h over a period of 7 h time. data as median (interquartile range). To compare Flunitrazepam was given as a bolus dose over 2 min BIS values the overall median of every patient was with 0.015 mg/kg. Drug administration was started computed and comparisons between the groups were at 11 pm propofol infusion was stopped at 6 am. To performed. Five second-values were displayed time ensure blinding drugs were given by nursing staff after dependently for every patient and in summary for both randomization. Patients were unaware of the used agents. groups. The study period was divided into 1-h sections and corresponding BIS values were compared between The day after the study night patients were asked to groups. According to the results of Sleigh et al.[18] BIS [17] evaluate their sleep by fi lling in the sleep diary. values were allocated to sleep stages. By using the BIS monitor alone it was not possible to identify rapid eye BIS movement (REM) sleep. Given that BIS values of light The BIS was recorded using the EEG system Aspect sleep and REM sleep are in the same range they had A-2000 System XP (Aspect Medical Systems, Natick, to be outlined. To minimize artifi cial variability of the 213 Indian Journal of Critical Care Medicine April 2014 Vol 18 Issue 4 BIS the data were concentrated to the 2-min median. of fl unitrazepam was injected over a period of 2 min. BIS values ≤74 corresponded to slow wave sleep (called Thereafter no further crucial respiratory alterations sleep stage A), BIS values of 75-89 to light sleep and occurred. Patients’ interventions and environmental REM sleep (called sleep stage B) and BIS values ≥90 noise were comparable between groups. to the awake state (called sleep stage C). Due to the missing data of the row EEG further fragmentation to Sleep diary the different non-REM (NREM) stages was not possible. The frequency of awakenings was lower in the Correlation analysis was performed with the Spearman Pg (median null events) compared with the Fg (median Rho correlation. A coeffi cient r > 0.4 and P ≤ 0.05 was 3.0 events [P < 0.001]). Patients who had received considered to be statistically signifi cant. propofol reported a maximum of six awakenings. After administration of fl unitrazepam patients declared up to Results thirty awakenings. Median duration of awakenings for Patient characteristics Fg was 15:00 min (P < 0.001) compared with 00:00 min A total of 66 patients aged between 19 and for Pg. The maximum duration of awakening for 83 years (Ø60.06 ± 12.02) were enrolled for the study.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages8 Page
-
File Size-