Fixed Orifice Tube and Thermal Expansion Valve Air Conditioning

Fixed Orifice Tube and Thermal Expansion Valve Air Conditioning

CDX Diesel HVAC Module 2: Fixed Orifice Tube and Thermal Expansion Valve Air Conditioning  FixED ORiFiCE TuBE AiR-COnDiTiOning SySTEm  COnTROL DEviCES  THERmOSTATiC ExPAnSiOn vALvE SySTEm  THERmAL ExPAnSiOn vALvES Fixed Orifice Tube Air-Conditioning System ready for review Fixed orifice tube system components Boiling and evaporating • Condenser • A drop in pressure causes the low-pressure, low- • Evaporator temperature liquid to boil. • Compressor • Liquid mist evaporates rapidly in the evaporator • Orifice tube coils. • Accumulator • Absorbs heat from air passing across the external • Connecting pipes and hoses fins • Thermostat Cooled air to the vehicle interior • Blower fans • Cooled air is directed to the interior of the vehicle • Pressure switches by blower fans. Orifice tube • Refrigerant in the evaporator flows on to the • Located between the condenser and the evaporator accumulator. • Provides the restriction to flow necessary for Accumulator system operation • Acts as a storage volume for the refrigerant Switching on the air-conditioning system • Separates the liquid from the vapor • The electromagnetic clutch is energized on the Refrigerant vapor enters the accumulator. compressor drive plate. • Enters at the top of the accumulator • The compressor is driven by the engine crankshaft. • Any liquid refrigerant falls to the bottom. Flow of vaporized refrigerant Final evaporation • Drawn from the low-pressure side of the system by • The accumulator is made from aluminum and has a the compressor large surface area. From the compressor to the condenser • Assists the final evaporation of any liquid • Discharged from the compressor as high-pressure, refrigerant leaving the evaporator high-temperature vapor Drawn through the outlet tube • Flows to the condenser • Refrigerant vapor is drawn off from the top of • Cooled by air flowing across the condenser coils the accumulator through the outlet tube by the and fins compressor. Condensation Hole in the outlet tube • A reduction in temperature causes the refrigerant • Small hole at the bottom of the outlet tube vapor to condense. • For small amounts of lubricating oil that settle at • Turns into liquid, which flows to the filter and then the bottom of the accumulator to the orifice tube • Drawn to the compressor Loss of pressure Accumulator filters and desiccants • Liquid refrigerant loses pressure by flowing • The accumulator contains filters and desiccants. through the fine tube. • Removes impurities and moisture from refrigerant • Forced to expand suddenly by passing through the passing through nozzle • Enters a larger volume of the evaporator © 2012 Jones & Bartlett Learning 1 CDX Diesel HVAC Module 2: Fixed Orifice Tube and Thermal Expansion Valve Air Conditioning Control Devices ready for review Purpose of control devices Cycling • To ensure maximum efficiency • Cycling adjusts the system to the heat load. • To protect components from damage High-pressure switch system protection Thermostat • System protection is needed against high • used to sense the temperature of evaporator fins pressures. • Helps ensure that the temperature does not drop • Provided by the high-pressure switch below 33.8°F (1°C) • mounted in the high-pressure line between the • if it drops to 32°F (0°C) or less, moisture condenser and the orifice tube condensing out of the air will freeze on the unit. High temperatures and pressures • Will block the flow through the evaporator • may develop if the condenser is unable to transfer When the temperature of the fins drops its heat effectively to the outside air • The fins of the evaporator drop to 33.8°F (1°C). • may be due to blockage of the condenser fins or • The thermostat contacts open. an inoperative electric fan • Breaks the electrical circuit to the compressor High-pressure switch clutch • if this occurs, the high-pressure switch open- • Stops the compressor from circulating refrigerant circuits the compressor clutch. When the temperature rises • Prevents the compressor from circulating • The evaporator temperature rises to about 39.2°F refrigerant (4°C). if a leak develops • The thermostat contacts close. • A leak may develop and refrigerant is low in • The electrical circuit to the compressor clutch is charge. restored. • The system pressure falls below a set value. Heat load increases. • The low-pressure switch on the low-pressure side • The fixed orifice tube cannot alter the amount of of the system turns the compressor off. refrigerant entering the evaporator. Lubricating oil • Therefore, extra cooling is required and heat load • A lack of lubricating oil can damage the on the system increases. compressor. • The compressor cycles on for longer periods. • Carried around the system by refrigerant Heat load decreases. • Prevents damage to the compressor • As heat load decreases, the compressor cycles off for longer. Thermostatic Expansion Valve System ready for review Components of the system • Also provides for the complete vaporization of all • Condenser liquid refrigerant entering the evaporator • Evaporator Refrigerant and lubricating oil • Compressor • The system is charged with refrigerant. • Receiver drier • Also charged with lubricating oil • Thermostatic expansion valve • Circulates with refrigerant at all times • Connecting pipes and hoses The air-conditioning system is switched on. • Thermostat • The electromagnetic clutch is energized on the • Blower fans compressor drive plate. • Pressure switches • The compressor is driven by the engine crankshaft. Thermostatic expansion valve vaporized refrigerant is drawn in. • Also called a Tx valve • Drawn in from the low-pressure side of the system • Located at the entry to the evaporator by the intake side of the compressor • Provides a throttling or restricting function to Discharged from the compressor control the quantity of refrigerant entering the • Discharged from the compressor as high-pressure, evaporator high-temperature vapor © 2012 Jones & Bartlett Learning 2 CDX Diesel HVAC Module 2: Fixed Orifice Tube and Thermal Expansion Valve Air Conditioning • Flows to the condenser Receiver drier • Cooled by air flowing across the condenser coils • Acts as a storage volume for liquid refrigerant and fins • Contains a filter and desiccant (drying material) Condensation and flow to the receiver drier Flow to reach the pick-up tube and Tx valve • A reduction in temperature causes refrigerant • Liquid refrigerant passes through the filter and vapor to condense. desiccant. • Turns into liquid, which flows to the receiver drier • Reaches the pick-up tube • Flows on to the Tx valve Thermal Expansion Valves ready for review Tx valve Changes in pressure • Determines the amount of liquid refrigerant flow • Reduces pressure in chamber “B” • A spring-loaded valve is controlled by different • Allows pressure in chamber “A” to move the valve pressures on each side of the connecting away from its seat by action of the diaphragm diaphragm. • High-pressure liquid flows through the orifice. Pressure in the chamber “A” side of the valve • Enters the evaporator as low-pressure liquid • Determined by the temperature sensing bulb Liquid expansion and then vaporization • The bulb is taped to the evaporator outlet. • Liquid expands into the larger volume of the • insulated from air temperatures evaporator. Sensing bulb • Causes a reduction in its pressure • Filled with refrigerant • Heat from the air passes over the evaporator fins. • Connected to chamber “A” by the capillary tube • Both actions cause liquid to vaporize. • The temperature at the evaporator outlet Low temperature of refrigerant leaving the determines the pressure in the bulb. evaporator Higher temperatures • interpreted by a sensing bulb attached to the • Will give higher pressures outlet • Will tend to open the Tx valve wider • if the temperature is low, refrigerant in the sensing • Allow more refrigerant to flow through bulb will contract. Lower temperatures • Pressure in chamber “A” of the Tx valve will • Will give lower pressures reduce. • Will tend to close the Tx valve Diaphragm movement • Reduce the flow of refrigerant • The diaphragm moves and the valve moves Pressure in the chamber “B” side of the valve towards the valve seat. • Determined by the refrigerant pressure in the • Reduces the quantity of refrigerant entering the evaporator evaporator • Also determined by the force supplied from the High temperature of refrigerant leaving the valve spring evaporator • The spring is often called the superheat spring. • Refrigerant in the sensing bulb expands. Superheat spring • Exerts more pressure in chamber “A” • Designed to ensure that the temperature of • Causes the valve to move away from its seat refrigerant leaving the evaporator is between • Allows more refrigerant to enter the evaporator 35.6°F to 48.2°F (2°C to 9°C) higher than Amount of refrigerant flow the boiling point of refrigerant at the current • Depends on the quantity of heat to be removed operating pressure from air passing over the evaporator fins Superheat • more heat means more refrigerant is required to • The difference in temperature is called remove it. “superheat.” • Less heat means less refrigerant is required. • Ensures that all liquid refrigerant entering the Control devices evaporator is vaporized before leaving • Fitted into the system When the compressor switches on • Ensure maximum efficiency • Suction from the compressor removes refrigerant • Operate as described in the section on the fixed vapor from the evaporator. orifice system • Lowers its pressure © 2012 Jones & Bartlett Learning 3.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    3 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us