The Interface Between Prefilled Syringe and Autoinjector – a Development Framework

The Interface Between Prefilled Syringe and Autoinjector – a Development Framework

Expert View THE INTERFACE BETWEEN PREFILLED SYRINGE AND AUTOINJECTOR – A DEVELOPMENT FRAMEWORK In this article, Jeffrey Philippson, PhD, Drug Delivery Test and Evaluation Specialist, and Tom Kemp, PhD, Drug Delivery Design and Optimisation Specialist, both of PA Consulting, outline the challenges for autoinjector developers at the interface between the device and the prefilled syringe – and describe a framework to formalise analysis of the interface. The prefilled syringe (PFS) has widely published benefits over “Formed glass barrel meets the traditional syringe and vial,1 leading to an increasing share precision-moulded parts, stopper of the drug delivery market glide force meets dynamic device in recent years.2 The addition spring-load, and syringe robustness of an autoinjector to deliver a PFS can enhance safety and the meets plunger impact load.” patient experience,3 opening up new opportunities for home- and self-administration.4 Finally, we extend the interface concept The typical starting point for beyond purely functional considerations development of an autoinjector solution, to include organisational challenges – whether a novel development or application dysfunction at the interfaces within and of a market-ready device, is an existing between organisations involved in selection PFS used in clinical trials – but this leaves and development of autoinjectors can mirror little opportunity for syringe selection challenges within the device. The benefits or modification. Many of the technical of getting it right are far-reaching and challenges facing device developers stem include rapid and effective evaluation of Dr Jeffrey Philippson from dysfunction at the interface between new PFS-autoinjector pairings, improved Drug Delivery Test and Evaluation Specialist the device and the primary container and device performance and reliability, and T: +44 1763 267 030 nowhere is this more evident than at the accelerated development timelines. E: jeffrey.philippson@ interface between PFS and autoinjector: paconsulting.com formed glass barrel meets precision-moulded CRITICAL DIMENSIONS AT parts, stopper glide force meets dynamic THE GEOMETRIC INTERFACE device spring-load, and syringe robustness meets plunger impact load. The most obvious point of contact at the This article outlines the key features of interface is the axial mounting of the PFS the interface between device and syringe, within the device. Early autoinjectors addressing the functional dependencies and mounted the PFS at the flange, which has the challenges that can arise. A framework the natural perpendicular geometry is then described to formalise the analysis to resolve the axial load during syringe of these features through the introduction emptying. Unfortunately, the geometry Dr Tom Kemp Drug Delivery Design and of an interface specification that brings that makes it so apparently suitable for Optimisation Specialist together overlapping requirements of the mounting also makes it a key weak point T: +44 7866 549 536 two subsystems to ensure compatibility and that is vulnerable to fracture under load. E: [email protected] drive the development of test methods that Unacceptably high rates of breakage on directly address critical interdependencies. firing were attributed to stresses on the PA Consulting Global Innovation and Technology Centre “The choice of mounting location and geometry defines Back Lane Melbourn many aspects of the final assembled device, including Hertfordshire critical requirements such as injection depth.” United Kingdom www.paconsulting.com 14 www.ondrugdelivery.com Copyright © 2019 Frederick Furness Publishing Ltd Expert View Figure 1: Diagram showing dimensions for manufacturing control and those critical to device functionality. A red cross indicates dimension typically not provided; a green tick indicates dimension typically provided. The details can vary from one manufacturer to another. The datum is the point on the syringe shoulder in contact with the device. flange, leading to recalls in extreme as the shoulder-to-needle-tip distance. cases.5 Something had to change. “In the new world of biologics, Figure 1 shows the critical measurements Most autoinjectors currently on from the points of view of manufacturing the market mount the PFS at the with higher spring loads required and device functionality. shoulder, where the needle meets to accommodate increased The story of in-use syringe breakages the glass body, which is the only volumes and viscosities, we as an may have further twists in store. In the other suitable surface. This change new world of biologics, with higher spring was adopted to reduce stress on the industry must remain vigilant.” loads required to accommodate increased flange.6 However, the impacts of volumes and viscosities, we as an industry that decision went far beyond the must remain vigilant and ensure the limits initial drivers that motivated it. mitigated by post-forming inspection. to syringe robustness are well understood. The choice of mounting location and To make matters worse, although all geometry defines many aspects of the manufacturers comply with the ISO- FORCE BALANCE final assembled device, including critical specified dimensions, varying processes can AT THE INTERFACE requirements such as injection depth. still result in different nominal geometries. The syringe shoulder is created by forming Needle placement during manufacture In addition to the geometric interface, semi-molten glass over a tungsten pin, and stoppering during fill and finish are the balance of forces between PFS and in a process that inevitably results in a usually referenced to the flange, resulting autoinjector is also critical to device variable geometry, although this can be in unpredictable offsets that appear as performance (Figure 2). The spring rate variability in critical dimensions such and precompression must be sufficient to overcome the stopper break-loose force to initiate syringe emptying, exceed the glide force to prevent stalling and achieve the required injection time. At the upper limit, spring load is limited by available space and the maximum impact force to avoid damage to the syringe and material creep in moulded parts. Although long springs with a low spring rate can seem like an ideal solution, with almost constant spring load, equilibrium spring length is limited Figure 2: A force diagram showing a by the challenge posed prefilled syringe being emptied under the by compressing very device spring load, showing the spring load long springs as part (Fs), stopper friction (Fk), fluid inertia (Fi), of an automated viscous drag (Fμ) and the resultant force (Fr). Arrows not to scale. assembly process. Copyright © 2019 Frederick Furness Publishing Ltd www.ondrugdelivery.com 15 Expert View The standard force characteristics measured by manufacturers and users “A critical task when integrating a PFS with an of PFSs in characterisation and quality control studies include the break-loose autoinjector is a detailed characterisation of the primary force and glide force at constant velocity. container, matching up measured characteristics of the Glide force is generally reported as a syringe with their counterparts in the device.” mean value at a given velocity, whereas design for a specified injection time must take account of the dynamic force profile of the combined drive system and load. materials or mechanical construction. characterisation tests to assess compatibility Consider that the spring load is constantly The choices of spring rate and between autoinjector and PFS. The decreasing as the spring expands, while precompression influence the observed development of the specification and the the stopper friction varies with both breakage force, necessitating a stepped associated tests is a crucial learning step velocity and lubrication. Siliconisation approach with multiple impacts at increasing that should be integral to the device reduces stopper friction but lubricant forces to produce a conservative estimate of development process. It further comes into mobility during stopper travel can add the threshold breakage force. Statistical its own when the inevitable question is further variability.7 analysis of the results must be undertaken asked: “Can the device deliver a different A critical characteristic that can be with care; breakage processes tend to be PFS?” Whether it is a new drug product, extremely challenging to quantify is the non-normal, with long high tails that can a new syringe or both, the interface threshold force for impact breakage. On lead to misinterpretation of results. specification provides a clear process and release, the plunger accelerates towards Cap removal force is an important unambiguous answers to critical questions the stopper under the applied spring characteristic of autoinjectors and, for of compatibility. load, generating a large transient force drugs indicated for acute conditions, can In an ideal world, the syringe on impact. Designers attempt to minimise be an essential performance requirement. requirements would simply be taken the initial gap between the plunger and Although a modest additional friction from the manufacturer drawings and stopper but the gap must be sufficient to component is added by the device, cap other specifications. However, life is avoid contact before firing, accounting for removal force is dominated by the force to rarely so simple. Dimensions specified by dimensional tolerances. Impact forces can remove the needle shield. Such

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us