Humphrey Field Analyzer 3 (HFA3)

Humphrey Field Analyzer 3 (HFA3)

2660021166131 Rev. A 2018-112660021166131 Rev. A 2018-11 Humphrey® Field Analyzer 3 (HFA3) Instructions for Use – Models 830, 840, 850, 860 ii Copyright ©2018 Carl Zeiss Meditec, Inc. All rights reserved. Trademarks FastPac, FORUM, Guided Progression Analysis, GPA, Humphrey, HFA, Liquid Trial Lens, SITA, SITA Fast, SITA Faster, SITA Standard, SITA-SWAP, STATPAC, RelEYE, Visual Field Index, and VFI are either registered trademarks or trademarks of Carl Zeiss Meditec, Inc in the United States and/or other countries. Windows, Windows Vista, and Windows Server are registered trademarks of Microsoft Corporation in the United States and/or other countries. HP is a registered trademark of Hewlett-Packard Company. Intel is a registered trademark of Intel Corporation. Bonjour, the Bonjour logo, and the Bonjour symbol are trademarks of Apple Computer, Inc. All other trademarks used in this document are the property of their respective owners. Patents www.zeiss.com/meditec/en_us/imprint/patents.html HFA3 Instructions for Use 2660021166131 Rev. A 2018-11 iii Table of Contents (1) Introduction . 1-1 Operating Principles . 1-1 Intended Use . 1-1 Indications for Use . 1-1 Purpose of This User Manual. 1-3 Symbols and Labels . 1-4 Instrument Disposition . 1-6 Disposal. 1-6 User Changes to Software or Hardware. 1-6 Instrument Installation . 1-7 HFA3 Licenses . 1-7 Product Compliance. 1-7 Product Safety . 1-7 Electromagnetic Compatibility (EMC) . 1-9 (2) Software Installation. .2-1 Contents Software Kit . 2-1 Steps to Upgrade Software . 2-1 (3) Getting Started. .3-1 Instrument Overview . 3-1 Startup. 3-9 Instrument Settings . 3-10 (4) Setup and Testing. .4-1 Perform Threshold or Suprathreshold Test. 4-1 Perform Kinetic Test. 4-15 Create Custom Test Patterns . 4-22 Set up Test Profiles . 4-24 Delete Test Profiles and Patterns . 4-24 (5) Quick Reference Guide. .5-1 Start Up . 5-1 Prepare for Testing . 5-1 Preliminary Tests (Optional). 5-4 Perform the Test . 5-5 Review and Save Results . 5-6 HFA3 Instructions for Use 2660021166131 Rev. A 2018-11 iv (6) Data, Tests & Reports. .6-1 Save Test Reports and Test Data . 6-1 Print Test Reports . 6-4 Reassign Tests . 6-4 Delete Tests . 6-4 Import Tests. 6-5 View and Generate Test Reports . 6-5 Merging and Deleting Patient Records . 6-6 Static Threshold Reports . 6-6 Report Features . 6-12 Suprathreshold Reports . 6-15 Kinetic Reports . 6-16 (7) Networking . 7-1 Network Capabilities . 7-1 Configuration to Pre-existing Office Network . 7-2 Connect to a DICOM/EMR Server. 7-3 Connect to a Printer. 7-8 (8) Maintenance . .8-1 Cleaning the Instrument . 8-1 Replacing the Stimulus Projection Lamp . 8-2 Liquid Trial Lens Care. 8-4 Accessories and Supplies List . 8-5 (9) Data Transfer . .9-1 Set Up a Serial Transfer from an HFA II or HFA II-i. 9-1 (10) Data Synchronization . 10-1 Installation & Configuration of Data Synchronization Function. 10-2 (11) Data Backup . 11-1 Data Backup on Shutdown and Data Restore . 11-1 (12) Specifications . 12-1 HFA3 Instrument . 12-1 (A) Test Patterns & Parameters. .A-1 Threshold Test Patterns . A-1 Suprathreshold Test Patterns. A-3 Test Parameters . A-8 (B) Determine Trial Lens . .B-1 HFA3 Instructions for Use 2660021166131 Rev. A 2018-11 v Guidelines for Trial Lens Selection . B-1 How to Calculate the Spherical Equivalent . B-1 (C) Troubleshooting. .C-1 Error Alerts . C-1 Troubleshooting Table . C-3 (D) Legal Notices. D-1 Software Copyright . D-1 End User Software License Agreement . D-1 HFA3 Instructions for Use 2660021166131 Rev. A 2018-11 vi HFA3 Instructions for Use 2660021166131 Rev. A 2018-11 Go to Contents Introduction 1-1 (1) Introduction This introductory section covers general information about the Humphrey® Field Analyzer 3 (HFA™3). Operating Principles A patient's visual field can be assessed by briefly projecting a spot of light (“stimulus”) of known size, brightness, and location on the inside surface of a roughly hemispherical bowl. Bowl illumination is controlled to establish a desired contrast between the stimulus and the area around it. Stimulus location and presentation timing are algorithmically varied to minimize the patient’s ability to anticipate stimulus location and timing. Stimulus brightness is algorithmically varied to determine the dimmest stimulus that can be reliably seen at each location. The resulting visual field map is used by a trained and qualified physician as an aid in diagnosis. Historically, also known as the Humphrey Field Analyzer (HFA), this instrument is the gold standard of perimetry worldwide. In addition to static perimetry, the HFA3 allows you to perform kinetic perimetry that emulates manual standard Goldmann perimetry. You can manually select kinetic isopters, or perform custom scans automatically or step by step. Intended Use The Humphrey Field Analyzer is an automatic perimeter which is.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    156 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us