E-STUDIO556/656/756/856 1 Ver10 08 Setting Mode

E-STUDIO556/656/756/856 1 Ver10 08 Setting Mode

e-STUDIO556/656/756/856 Sub- Default Acceptable Proc 05/08 Mode Element Sub Element Item Subitem Code Details RAM Contents ServiceUI Code value value edure 08 Setting ProcessFuser 2002Fuser unit counter 0 0~29M 0: No error 1: C411 2: C412 3: C443 4: - 5: 1 mode C445/465 6: C446/466 7: C447/467 8: C468 9: C449 10: C475 11: C471 12: C472 13: C473 14: C481 15: C480 16: C474 17: C490 18: C468 19: C449 20: C468 21: C449 22: C449 23: C449 24: C447/C467 25: C449 26: C468 27: C449 28: C468 29: C449 08 Setting Process Fuser 2009Fuser roller temperature at Refer to 0~14M 0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 1 mode ready status contents 165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:195°C 12: 200°C 13:205°C 14: 210°C <Default value> e-STUDIO556 UC, EUR: 12 e-STUDIO656 JPC: 9 UC, EUR: 12 e-STUDIO756/856 JPC: 12 UC, EUR: 12 08 Setting Process Fuser 2010Fuser roller temperature 120~14M 0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 1 mode during printing(Plain paper) 165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:195°C 12: 200°C 13:205°C 14: 210°C 08 Setting Process Fuser 2028Fuser roller temperature 120~14M 0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 1 mode during printing(Thick paper 165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 3) 190°C 11:195°C 12: 200°C 13:205°C 14: 210°C 08 Setting Process Fuser 2031Pre-running time for first 0 0~15M 0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 1 mode printing(Thick paper 3) sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11: 12 sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec 08 Setting Process Fuser Energy Saving 2042Fuser roller temperature Refer to 0~27M 0: OFF 1: 50°C 2: 55°C 3: 60°C 4: 65°C 5: 70°C 6: 1 Yes mode Mode contents 75°C 7: 80°C 8: 85°C 9: 90°C 10: 95°C 11:100°C 12: 105°C 13:110°C 14: 115°C 15:120°C 16: 125°C 17:130°C 18: 135°C 19:140°C 20: 145°C 21:150°C 22: 155°C 23:160°C 24: 165°C 25:170°C 26: 175°C 27:180°C <Default value> e-STUDIO556 UC, EUR: 19 e-STUDIO656 JPC: 5 UC, EUR: 22 e-STUDIO756/856 JPC: 22 UC, EUR: 25 08 Setting Process Fuser 2049Fuser roller temperature 120~14M 0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 1 mode during printing(Thick paper 165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 1) 190°C 11:195°C 12: 200°C 13:205°C 14: 210°C 08 Setting Process Fuser 2050Fuser roller temperature 120~14M 0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 1 mode during printing(Thick paper 165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 2) 190°C 11:195°C 12: 200°C 13:205°C 14: 210°C 08 Setting Process Fuser 2051Fuser roller temperature 8 0~14M 0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 1 mode during printing(OHP film) 165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:195°C 12: 200°C 3:205°C 14: 210°C 08 Setting Process Fuser 2052Pre-running time for first 5 0~15M 0: Invalid 1: 0 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 1 mode printing (OHP film) sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11: 12 sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec. 08 Setting Process Fuser 2053Pre-running time for first 0 0~15M 0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 1 mode printing(Plain paper/Low sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 temperature environment) sec. 11: 12 sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec. 08 Setting Mode 1 Ver10 e-STUDIO556/656/756/856 Sub- Default Acceptable Proc 05/08 Mode Element Sub Element Item Subitem Code Details RAM Contents ServiceUI Code value value edure 08 Setting ProcessFuser 2054Pre-running time for first 0 0~15M 0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 1 mode printing(Thick paper 1) sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11: 12 sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec. 08 Setting Process Fuser 2055Pre-running time for first 0 0~15M 0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 1 mode printing(Thick paper 2) sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11: 12 sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec. 08 Setting Process Fuser 2057Fuser unit pre-running Refer to 0~16M 0: 100°C 1: 110°C 2: 120°C 3: 125°C 4: 130°C 5: 1 mode period end contents 135°C 6: 140°C 7: 145°C 8: 150°C 9: 155°C 10: temperature(Pressure 160°C 11:165°C 12: 170°C 13:175°C 14: 180°C roller)(Normal temperature / 15:185°C Option not installed) 16: 190°C <Default value> e-STUDIO556 UC, EUR: 4 e-STUDIO656/756/856 JPC: 2 UC, EUR: 4 08 Setting Process Fuser 2058Low-speed pre-running Refer to 0~16M 0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6: 1 mode starting temperature during contents 80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11:105°C ready status(Pressure 12: 110°C 13:115°C 14: 120°C 15:125°C 16: 130°C roller)(Option not installed) <Default value> e-STUDIO556 UC, EUR: 16 e-STUDIO656 JPC: 6 UC, EUR: 16 e-STUDIO756/856 JPC: 16 UC, EUR: 16 08 Setting Process Fuser 2059Low-speed pre-running Refer to 0~9M 0: 5°C 1: 10°C 2: 15°C 3: 20°C 4: 25°C 5: 30°C 6: 1 mode stopping temperature during contents 35°C 7: 40°C 8: 45°C 9: 50°C ready status(Pressure <Default value> roller)(Option not installed) e-STUDIO556 UC, EUR: 2 e-STUDIO656 JPC: 5 UC, EUR: 2 e-STUDIO756/856 JPC: 2 UC, EUR: 2 08 Setting Process Fuser 2060Threshold of low 7 0~11M The boundary temperature of the low and normal 1 mode temperature environment temperature control can be set. control 0: 0°C 1: 5°C 2: 9°C 3: 10°C 4: 12°C 5: 14°C 6: 15°C 7: 16°C 8: 17°C 9: 18°C 10: 19°C 11: 20°C 08 Setting Process Fuser 2084Low-speed pre-running Refer to 0~1M 0: Performs prerunning 1: No pre-running 1 mode setting at recovery from contents <Default value> Energy Saving Mode e-STUDIO556 UC, EUR: 0 e-STUDIO656 JPC: 1 UC, EUR: 0 e-STUDIO756/856 JPC: 0 UC, EUR: 0 08 Setting Process Fuser 2105Pre-running period end 8 0~16M 0: 100°C 1: 110°C 2: 120°C 3: 125°C 4: 130°C 5: 1 mode temperature(Pressure 135°C 6: 140°C 7: 145°C 8: 150°C 9: 155°C 10: roller)(Low temperature) 160°C 11:165°C 12: 170°C 13:175°C 14: 180°C 15:185°C 16: 190°C 08 Setting Process Fuser 2117Pre-running period end Refer to 0~16M 0: 100°C 1: 110°C 2: 120°C 3: 125°C 4: 130°C 5: 1 mode temperature(Pressure contents 135°C 6: 140°C 7: 145°C 8: 150°C 9: 155°C 10: roller)(Normal temperature / 160°C 1:165°C 12: 170°C 13:175°C 14: 180°C Option installed) 15:185°C 16: 190°C <Default value> e-STUDIO556/656: TWD: 6 Others: 4 e-STUDIO756/856: NAD/SAD: 6 Others: 4 08 Setting Mode 2 Ver10 e-STUDIO556/656/756/856 Sub- Default Acceptable Proc 05/08 Mode Element Sub Element Item Subitem Code Details RAM Contents ServiceUI Code value value edure 08 Setting Process Fuser 2122Low-speed pre-running 160~16M 0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6: 1 mode starting temperature during 80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11:105°C ready status(Pressure 12: 110°C 13:115°C 14: 120°C 15:125°C 16: 130°C roller)(When options are installed) 08 Setting ProcessFuser 2123Low-speed pre-running 2 0~9M 0: 5°C 1: 10°C 2: 15°C 3: 20°C 4: 25°C 5: 30°C 6: 1 mode stopping temperature during 35°C 7: 40°C 8: 45°C 9: 50°C ready status(Pressure roller)(When options are installed) 08 Setting Process Fuser 2130Switching timing into low- 1 0~12M 0: Switching disabled 1: 5 min.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    107 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us