Pure performance STEADY ™ 1300 SERIES Readily available pure performance pumps Available EASY TO SELECT, CLOSE AT HAND, RIGHT PUMP FOR YOUR NEEDS Value for money EFFICIENT, POWERFUL Steady™ 1300 is a series of submersible pumps that deliver pure performance at outstanding value. Combining performance and quality in a The Steady 1300 series is based on convenient, value for money package, these technology developed and tested in pumps will help ensure the smooth running tough environments the world over. Reliable and profitability of your operation. This is That’s why you can count on these pumps SOLIDS HANDLING, CONTINUOUS RUNNING why Steady is the ideal pump for sewage for trouble-free, reliable operation. and surface wastewater within municipal and commercial building applications. The hydraulic design of the pumps has been proven to reduce clogging and Moreover, Steady makes your choice of maintain efficiency. These pumps simply pump easy, it only requires three straight- work–and keep on working. Day in, day forward steps. We have the right pump out, and under harsh conditions, they for your needs with high availability to won’t let you down–they´re Steady. support your business. 2 3 Available Tough Value for money to beat Reliable Robust Environmentally friendly All components are made from Cooling system is designed to robust materials for easy main- use the surrounding media to tenance and long life. cool the pump; no use of envi- ronmentally hazardous fluids such as oils. Powerful Safe and straightforward Motor is specifically designed Cable entry prevents both cable for reliable operation in sub- strain and leakage. mersible applications. It can run continuously without overheat- ing – a true workhorse. With a variety of model and Steady 1300 continuous running without overheating, impeller combinations, it’s easy to find ensuring optimal cooling and long lifetime. a pump for your needs. The optimized Additionally, the pumps can handle 15 impeller design ensures efficient solids starts per hour without problem. handling capability, smooth operation, Durable Smooth and increased savings from reduced Typically these pumps are installed in Heavy-duty bearings with long The double mechani- maintenance costs and lower energy permanent installations. However, some life provide peace of mind. cal seal provides extra consumption. models have the option of a free-standing reliability and protects installation so that the pump can be against leakage. All pumps in the series feature a motor easily moved from one site to another. designed for reliable operation in See methods of installation (page 6) for submersible applications. The motors further reference. have F-class insulation, which allows for Flexible Drilled pump housing, Application areas ready for any installa- tion method. Municipal: Commercial building: · Domestic sewage pumping stations · Drainage water · Wastewater pumping stations · Domestic sewage pumping stations · Retention basins · Ground water · Storm water pumping stations 4 5 Installation methods and Selecting & ordering Configure your product order and generate order number accessory kits We’ve made it easy for you to select and configure your pump with appropriate accessories; it’s done in just three simple steps and you build your order number as you go. The Steady 1300 series is designed to fit your needs. 1 Select the pump model ideal for your needs from the product pages that follow. You start with a bare pump and order the right kit depending on your desired installation method. For every model and choice 2 of outlet dimension there is a partially filled order number. Wet-well kit Configure your pump from the Guide bars relevant selection tables and you Outlet dimension The pump is installed with twin Model Model variant Pole FrequencyPhase (5=50, 6=60) not included (nominal, mm) guide bars on a discharge connection. will automatically get the informa- tion to build and complete your 1320M-100P.453.---.---/- Kit contents: order number as you go! • Discharge connection Selected model A B C D • Anchor bolts • Guide claw with bolts • Upper guide bar bracket with bolts C Voltage permanent Replacement kit Simple kit to replace an old pump or upgrade to a larger model Upgrade Kit contents: • Guide claw with bolts B Curve ID D transportable A Cable Installation- length code Free-standing kit Ideal for portability Kit contents: Select your accessory kit from the relevant accessory selection tables, i.e. installation kit. Please • Hose connection with bolts 3 make sure that your configuration corresponds to the right order number and accessory kits and • Stand with bolts you are ready to order. 6 7 Pump data ™ Model 1310S Impeller Type Non-clog Steady 1310 Outlet size (mm) 50 Weight (kg) 35 Pole 2 Non-clog Insulation Class F Starts per hour 15 Motor data Voltage 380 V 400 V Phase 3 3 Model 1310S 1310S Starting Amps (A) 25 27 Full Load (A) 5,2 5,1 Full Loal Power Factor 0.90 0.86 Connection Y Y Cable 4G1.5 4G1.5 Material data Process data Impeller stainless steel Max submergence 20 m Pump housing grey cast iron Max fluid temp 40 C Stator housing grey cast iron pH range of pumped liquid 5,5 - 14 Shaft stainless steel Inner mechanical seal carbon/aluminum oxide Power cable data Outer mechanical seal cemented carbide/aluminum oxide Cable type (mm2) 4G1.5 O-rings nitrile Outer Diameter (mm) 11.5 Cable sheathing nitrile Weight (kg/m) 0.20 Performance curves Pump dimensions (mm) DNDN 5 500 25 20 S60 [2,36kW] S64 [1,64kW] 15 ) m ( H 10 S60 5 S64 0 1310S 1310S 0 2 4 6 8 10 12 14 16 Q (l/s) 0 15 30 45 60 Q (m3/h) A N/A F 115 B 503 G 125 C 309 H 157 D 119 J N/A E 190 K N/A Selection table* Installation kit selection table* Model Outl (in) Installation Pole Freq (Hz) Phase Max Shaft Power Curve no Voltage Cable Order number* DN Free-standing Wet well Replacement 1310S 50 P, S 2 50 3 [see chart] S60, S64 380, 400 10 1310S-50-.253.---.---/- 50 included 1310-50P 1310-50R * Pumps come standard with thermal switches. For information on configuring the right order number, see page 7. * For more information, see page 6 8 9 Pump data ™ Model 1310H 1310M Impeller Type Vortex Vortex Steady 1310 Outlet size (mm) 50 65 Weight (kg), with stand 34 40, 50 Pole 2 2 Vortex Insulation Class F F Starts per hour 15 15 Motor data Voltage 380 V 400 V 1510 . Pure performance . 1 . Master . 1 . 20120910 1 . Master . 1 . performance . Pure 1510 . Phase 3 3 Model 1310H/M 1310H/M Starting Amps (A) 25 27 Full Load (A) 5,2 5,1 Full Loal Power Factor 0.90 0.86 Connection Y Y Cable 4G1.5 4G1.5 Material data Process data Impeller grey cast iron Max submergence 20 m Pump housing grey cast iron Max fluid temp 40 C Stator housing grey cast iron pH range of pumped liquid 5,5 - 14 Shaft stainless steel Inner mechanical seal carbon/aluminum oxide Power cable data Outer mechanical seal cemented carbide/aluminum oxide Cable type (mm2) 4G1.5 O-rings nitrile Outer Diameter (mm) 11.5 Cable sheathing nitrile Weight (kg/m) 0.20 Performance curves Pump dimensions (mm) DN50DN 50 DN65DN 65 18 18 16 V51 [2.3kW] 16 V31 [2.4kW] V53 [1.54kW] V33 [1.89kW] 14 V55 [1.15kW] 14 V35 [1.49kW] 12 12 10 10 H [m] 8 H [m] 8 6 6 4 V51 4 V53 V35 V33 V31 2 V55 2 1310H 1310M 1310H 1310M 0 0 0 5 10 Q [l/s] 0 5 10 15 20 Q [l/s] A N/A N/A F 115 106 0 10 20 30 40 50 Q [m3/h] 0 10 20 30 40 50 60 70 Q [m3/h] B 503 503 G 125 106 C 309 410 H 157 280 D 119 119 J N/A N/A E 190 291 K N/A N/A Selection table* Installation kit selection table* Model Outl (in) Installation Pole Freq (Hz) Phase Max Shaft Power Curve no Voltage Cable Order number* DN Free-standing Wet well Replacement 1310H 50 P, S 2 50 3 [see chart] V51, V53, V55 380, 400 5 1310H-50-.253.---.---/5 50 included 1310-50P 1310-50R 1310M 65 P, S 2 50 3 [see chart] V31, V33, V35 380, 400 5 1310M-65-.253.---.---/5 65 1310-65S 1310-65P 1310-65R * Pumps come standard with thermal switches. For information on configuring the right order number, see page 7. * For more information, see page 6 10 11 Pump data ™ Model 1315S 1315M Impeller Type Non-clog Non-clog Steady 1315 Outlet size (mm) 80 100 Weight (kg), with stand 95, 109 120, 135 Pole 2 4 Non-clog Insulation Class F F Starts per hour 15 15 Motor data Voltage 380 V 400 V Phase 3 3 Model 1315S | 1315M 1315S | 1315M Starting Amps (A) 45 | 31 49 | 33 Full Load (A) 8,9 | 7,5 8,6 | 7,4 Full Loal Power Factor 0.93 | 0.87 0.90 | 0.83 Connection D | Y D | Y Cable 7G1.5 7G1.5 Material data Process data Impeller grey cast iron Max submergence 20 m Pump housing grey cast iron Max fluid temp 40 C Stator housing grey cast iron pH range of pumped liquid 5,5 - 14 Shaft stainless steel Inner mechanical seal carbon/aluminum oxide Power cable data Outer mechanical seal cemented carbide/aluminum oxide Cable type (mm2) 7G1.5 O-rings nitrile Outer Diameter (mm) 16,2 Cable sheathing nitrile Weight (kg/m) 0,33 Performance curves Pump dimensions (mm) DN 80 DN 100 35 16 S70 [4,16kW] 30 14 S60 [2,97kW] S74 [3,11kW] S62 [2,11kW] 12 S63 [1,75kW] 25 10 20 ) ) m m ( ( 8 H 15 H 6 10 4 1315S 1315M 1315S 1315M 5 S70 S60 2 S62 S63 S74 A 608 624 F 190 190 0 0 0 5 10 15 20 25 30 Q (l/s) 0 10 20 30 40 50 60 Q (l/s) B 508 524 G 190 190 0 30 60 90 Q (m3/h) 0 60 120 180 Q (m3/h) C 420 475 H 90 109 D 190 190 J 190 209 E 230 285 K 100 100 Selection table* Installation kit selection table* Model Outl (in) Installation Pole Freq (Hz) Phase Max Shaft Power Curve no Voltage Cable Order number* DN Free-standing Wet well Replacement 1315S 80 X 2 50 3 [see chart] S70, S74 380, 400 10 1315S-80-.253.---.---/- 80 1315-80S 1315-80P 1315-80R 1315M 100 X 4 50 3 [see chart] S60, S62, S63 380, 400 10 1315M-100-.453.---.---/- 100 1315-100S 1315-100P 1315-100R * Pumps come standard with thermal switches.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages16 Page
-
File Size-