OUTFALL DESIGN AND CONSTRUCTION CONTENTS: Drawing No. 1158-2413 Drawing No. 1158-2414 Drawing No. 1158-2415 Drawing No. 1158-2416 Drawing No. 1158-2417 Drawing No. 1158-241 8 Drawing No. 1 158-2419 Outline Description of Outfall Design and Construction For inspection purposes only. Consent of copyright owner required for any other use. EPA Export 25-07-2013:22:43:47 - WWTP SITE BOUNDARY - PRIMARY DISCHARGE 1. ALL LEVELS SHOWN REWTETOORMiANCE IURYE" MWU AT MLLINHViD I I I I , Clnt For inspection purposes only. Consent of copyright owner required for any other use. LOUTH COUNTY COUNCIL DROGHEDA WASTE WATER DISCHARGE LICENCE APPLICATION PRIMARY D SCrlARGE PO hT COhSTR,CTION 8 DES GN <SECTION 1 ATTACHMENT C.2 L Pm* 0-r. MICHAEL F. GARRlCK EPA Export 25-07-2013:22:43:47 - WWTP SITE BOUNMRY I For inspection purposes only. Consent of copyright owner required for any other use. SECTION I ATTACHMENT CE EPA Export 25-07-2013:22:43:47 WWTP SITE BOUNDARY STORM WATER For inspection purposes only. Consent of copyright owner required for any other use. DROGHEDA WASTE WATER I DlSCnARGE LlCEhCE KEY PLAN SECTlONl#ZWtCHMENT C.B& mpnr(ql: cwSp we RK E S. SEPT '07 EPA Export 25-07-2013:22:43:47 WWTP SITE / CONCRETE APRON I BOUNDARY ON TlhdBER PILES % STDW WATER c OVERPLBW DWOHARGE For inspection purposes only. Consent of copyright owner required for any other use. DROGHEDA WMTE WRTER DISZHARGE LICEMCE rx. STORM WATER OVERFLOW DISCHARGE POIMTS CONSTRUCTION % DESIGN SHEET 1 OF 4 ,( ,( SECTIONd.ATPACHMENT l2.Z.k EPA Export 25-07-2013:22:43:47 STORM WATER OVERFLOWDISCHARGE POINTS For inspection purposes only. Consent of copyright owner required for any other use. EPA Export 25-07-2013:22:43:47 STORM WATER OVERFLOW Q DISCHARGE POINTS For inspection purposes only. Consent of copyright owner required for any other use. EPA Export 25-07-2013:22:43:47 STORM WATER . OVERFLOW DISCHARGE 1 POINTS For inspection purposes only. Consent of copyright owner required for any other use. EPA Export 25-07-2013:22:43:47 OUTLINE DESCRIPTION OF OUTFALL DESIGN AND CONSTRUCTION 1.0 PRIMARY DISCHARGE POINT Location: Boyne Estuary Marsh Road (approximately 2km east of the WWTP) Diffuser - 4 no. Outlet Points: 312565E-275882N 312515E-275863N 312523E-275947N 312497E-275938N Receiving Water: Boyne Estuary Originates: Final Treated Effluent WWTP, Marsh Road, Drogheda Invert Level: -2.71111 Pipe Size: 1000mm0 pipe from WWTP 700mm0 pipe Across River 4 x 500mm0 pipe - Diffusers Design Criteria: Continuous Flow of Treated Effluent from WWTP Construction Detail: Diffusers Supported on Timber Piles 2.0 SECONDARY DISCHARGE POINT Location: 310245E-275473N Receiving Water: River Boyne Originates: Emergency Overflow Newtown Pumping Station, South Bank River Boyne, Drogheda Invert Level: - Pipe Size: 1600mm0 For inspection purposes only. Consent of copyright owner required for any other use. Design Criteria: Penstock Controlled EmergencylSafety Overflow Only to Operate in Case of Pump Failure Construction Detail: On Concrete Apron IGabion Mattress 3.0 STORM WATER OVERFLOW DISCHARGE POINTS 3.1 swo-1 Location: 312502E-275858N Receiving Water: Boyne Estuary Originates: Storm Water Holding Tanks WWTP, Marsh Road, Drogheda lnvert Level: Pipe Size: 700mm0 Design Criteria: To Relieve Surge Charges on Storm Water Holding Tank, Due to Heavy Precipitation Conditions Construction Detail: Concrete Apron on Timber Piles EPA Export 25-07-2013:22:43:47 3.2 SWO-2 Location: 309745E-275465N (North Bank River Boyne, Drogheda) Receiving Water: River Boyne Originates: Manhole, North Bank River Boyne, Drogheda lnvert Level: Unknown - Old Sewer Pipe to River Pipe Size: 375mm0 Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown - Old Sewer Pipe to River 3.3 SWO-3 Location: 309270E-275159N (North Bank River Boyne, Drogheda) Receiving Water: River Boyne Originates: Manhole, North Bank River Boyne, Drogheda lnvert Level: Unknown - Old Sewer Pipe to River Pipe Size: Unknown - Old Sewer Pipe to River Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown - Old Sewer Pipe to River 3.4 SWO-4 Location: 309055E-275029N (North Bank River Boyne, Drogheda) Receiving Water: River Boyne Originates: Manhole, North Bank River Boyne, Drogheda lnvert Level: Unknown - Old Sewer Pipe to River Pipe Size: 900mm0 Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown - Old Sewer Pipe to River 3.5 SWO-5 Location: 308783E-274989N (North Bank River Boyne, Drogheda) For inspection purposes only. Receiving Water: RiverConsent Boyne of copyright owner required for any other use. Originates: Manhole, North Bank River Boyne, Drogheda lnvert Level: Unknown - Old Sewer Pipe to River Pipe Size: 450mm0 Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown - Old Sewer Pipe to River 3.6 SWO-6 Location: 308576E-275079N (North Bank River Boyne, Drogheda) Receiving Water: River Boyne Originates: Manhole, North Bank River Boyne, Drogheda lnvert Level: Unknown - Old Sewer Pipe to River Pipe Size: 750mm0 Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown - Old Sewer Pipe to River EPA Export 25-07-2013:22:43:47 3.7 SWO-7 Location: 308151E-275361N (North Bank River Boyne, Drogheda) Receiving Water: River Boyne Originates: Manhole, North Bank River Boyne, Drogheda lnvert Level: Unknown - Old Sewer Pipe to River Pipe Size: Unknown - Old Sewer Pipe to River Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown - Old Sewer Pipe to River 3.8 SWO-8 Location: 307648E-275426N (North Bank River Boyne, Drogheda) Receiving Water: River Boyne Originates: Manhole, North Bank River Boyne, Drogheda lnvert Level: Unknown - Old Sewer Pipe to River Pipe Size: 450mm0 Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown - Old Sewer Pipe to River 3.9 SWO-9 Location: 308625E-274998N Receiving Water: River Boyne Originates: Manhole, South Bank River Boyne, Drogheda lnvert Level: Unknown Pipe Size: Unknown Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown 3.10 SWO-10 Location: 308847E-274949N For inspection purposes only. Receiving Water: RiverConsent Boyne of copyright owner required for any other use. Originates: Manhole, South Bank River Boyne, Drogheda lnvert Level: Unknown Pipe Size: Unknown Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown 3.11 SWO-I1 Location: 309064E-275000N Receiving Water: River Boyne Originates: Manhole, Bull Ring, South Bank River Boyne, Drogheda lnvert Level: Unknown Pipe Size: 450mm0 Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown EPA Export 25-07-2013:22:43:47 3.12 SWO-12 Location: 309232E-275087N Receiving Water: River Boyne Originates: Manhole, Mary Street, South Bank River Boyne, Drogheda Invert Level: Unknown Pipe Size: 450mm0 Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown 3.13 SWO-13 Location: 309671E-275280N Receiving Water: River Boyne Originates: Manhole, Carmelite Cottages, South Bank River Boyne, Drogheda lnvert Level: Unknown Pipe Size: 375mm0 Design Criteria: To Relieve Surge Charges in Sewer Network, Due to Heavy Precipitation Conditions Construction Detail: Unknown For inspection purposes only. Consent of copyright owner required for any other use. EPA Export 25-07-2013:22:43:47.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages12 Page
-
File Size-