Overhead Dist Transformers

Overhead Dist Transformers

Overhead Distribution Transformers 5-1000 kVA Single Phase 30-500 kVA Three Phase About Power Partners, Inc. Power Partners, Inc. manufactures poletype distribution transformers that provide more than 3,000 utilities in North America, Central America, the Middle East and Asia with electric power for homes and businesses. Power Partners’ poletype distribution transformers are specifically designed to serve residential overhead distribution loads. They are also suit- able for light commercial loads, industrial lighting, and diversified power applications. Power Partners provides a complete line of overhead transformers to meet the applica- tions of any distribution system. The company The Value of Quality manufactures single-phase and three-phase Power Partners is committed to achieving total poletype transformers at 34.5 kV and below, customer satisfaction and industry leadership in ratings from 5-1000 kVA single-phase and through continuous process improvement. 30-500 kVA three-phase. The Power Partners The company’s employees are team-based and core-coil design provides optimum efficiency measurement focused, and their work is based and excellent mechanical, thermal and electri- on highly disciplined processes. The company cal performance. is innovative, reliable and driven to provide The Power Partners operation in Athens, GA, high quality and high value, and to meet each has achieved ISO 9001: 2008 certification. The delivery commitment. We want Power Partners operation, which was an ABB facility until to be recognized as a company that exceeds Power Partners purchased it in May 2003, has customers’ expectations. nearly 50 years of manufacturing experience. An Industry Leader The ABB Connection Working together with ABB as the man- The poletype distribution transformers manu- ufacturer’s representative for Power Partners, factured by Power Partners are marketed for we have alliances with major utilities and ABB, with ABB serving as the manufacturer’s businesses around the world providing representative for Power Partners. ABB is a products and services to meet all their needs. global leader in power and automation tech- To g e t h e r, we are a dominant force in the nologies that enable utility and industry industry. customers to improve their performance, while lowering their environmental impact. Manufacturing Technology Overhead distribution transformers manufac- tured by Power Partners offer cost-effective solutions for power distribution. The latest manufacturing technology is utilized to main- tain state-of-the-art quality and productivity. Large vertical integration allows us to ship high quality products in the shortest possible production cycle. POWER PARTNERS 3 Single Phase Overhead Distribution Transformers Power Partners single phase, oil-filled, pole-mounted dis - 13. The paint finish process applies a durable, corrosion tribution transformers are specifically designed for servic - resistant finish to the product. The finish meets or ing residential overhead distribution loads. They are also exceeds all the performance requirements of ANSI suitable for light commercial loads, industrial lighting and C57.12.28. The multi-step process includes an epoxy diversified power applications. These transformers are primer uniformly applied by cationic electro-deposition designed for the application conditions normally encoun - and a urethane top coat. tered on electric utility power distribution systems. The following additional features are all standard on self-protected type CSP ® units: 14. Primary protective link. 15. Surge arrester. 16. Secondary circuit breaker. 17. Secondary breaker operating handle with emergency overload reset and overload signal light. 18. Tank bottom rim is three layers thick for increased durability and resistance to shipping and handling damage. ® Type CSP Ratings • 5-1000 kVA • 65° C temperature rise Type S • 60 hertz standard, 50 hertz optional • Low voltages: 120/240, 240/480 and 277 • High voltages: 2400 through 34,400 Volts • Insulation levels: Rated Voltage Insulation Basic Impulse Ranges Class Level (kV) Options 480-600 1.2 30 2160-2400 5.0 60 Primary Termination 4160-4800 8.7 75 • Cover-mounted high voltage porcelain bushing(s) with 7200-12470 15.0 95 spin top terminal. Optional 125 kV BIL 12000 volts available. • Side-wall mounted high voltage porcelain bushing(s) 13200-14400 18.0 125 with spin top terminal (Standard on all 4800 volts and 19920-22900 25.0 150 below). Optional 125 kV BIL 19920 volts available. Secondary Termination 34400 34.5 200 • Low voltage porcelain bushings with NEMA spade termi - nals (Standard on all units 167 kVA and above). Standard Features: Primary Switching 1. Lifting lugs. • Externally-operated tap changer. 2. Cover-mounted high voltage porcelain bushing(s) • Externally-operated dual voltage switch or internal with eyebolt terminal (10-100 kVA) or spade terminal. terminal board. 3. Low voltage insulators are available in fiberglass rein - Overcurrent Protection forced polyester material or porcelain (both eyebolt • Internally-mounted current limiting fuse in series with and spade terminals). protective link. 4. Low voltage neutral grounding strap (furnished on 10-50 kVA single HV bushing units). Contact the division for voltages and dimensions on 667 through 1000 kVA. 5. ANSI support lugs (hanger brackets). 6. Cover has 13 mils minimum of polyester coating pro - Optional Accessories viding 15 kV dielectric insulation of tank ground parts 1. High voltage bushings are of two types and are made from live parts and increased resistance to corrosion. of wet process porcelain: 7. Self-venting and resealing cover assembly. • Speed wrench operable eyebolt bushing for cover 8. The core/coil bolt-in pads are 180° apart. mounting. 9. Embossed low voltage leads. • Spin-top bushings for either cover or side-wall mount. 10. Oil filled plug with cover ground strap. 2. Tap changers compensate for small voltage variations along the distribution system. The externally- 11. Tank ground pad. operated tap changer is a single-phase, five-position 12. Laser etched anodized aluminum nameplate with bar design for de-energized operation. coded serial number. 4 POWER PARTNERS 3. A dual voltage switch permits use of the same trans - • The MOV polymer arresters handle surges of former on distribution systems with different system 65,000 amperes (small block) and 100,000 voltages. amperes (large block). 4. The CSP ® protection package consists of four related • Secondary circuit breakers protect against over - components that work together to provide complete loads and external short circuits. self-contained protection against surge • An optional current limiting fuse supplements the currents, short circuits and overloads: protective link when the fault current exceeds the • The protective link removes an internally-faulted link’s rating. transformer from the primary line, maintaining 5. Stainless steel tanks and covers are available. service to other customers on the line not served by the faulted unit. Overhead Distribution Transformers Approximate weights and dimensions APPROXIMATE WEIGHTS AND DIMENSIONS Standard Design Dimensions and Weights OVERHEAD DISTRIBUTION TRANSFORMERS (All weights and dimensions are approxi - mate. Dimensions may change to meet the customer spec.) A Single Phase, 60 HZ, OISC, 65° Rise High E Voltage ABB (Refer to Division for available tap D positions and dimensions for other primary voltages.) Low Voltage 120/240 or 240/480 or 277 E C B Standard Performance level A 75-100 KVA D E A C B ABB 167 - 500 KVA D C B 1.5 - 50 KVA Overall weights and dimensions are given in pounds, inches or gallons and are approximates A = Overall Height, B = Overall Width, C = Overall Depth, D = Tank Diameter, E = Hanger Spacing 1 Phase Type ‘S’ - Class 0A - 7200 /12470Y Primary Voltage KVA ABCDEWgt Ship Wgt OIL Qty 10 34 17 20 13.25 11.25 205 217 11 15 36 17 20 13.25 11.25 236 247 12 25 41 19 22 15.25 11.25 349 363 18 37.5 44 22 24 17.5 11.25 489 510 29 50 49 22 24 17.5 11.25 585 605 31 75 49 25 27 20 23.25 850 875 40 100 50 27 28 20 23.25 923 968 42 167 58 38 33 24 23.25 1475 1542 78 250 66 38 33 24 24 1820 1885 90 333 62 42 37 24 24 2040 2110 82 500 66 45 41 27 36 2850 2950 109 Type ‘S’ - Class 0A - 14400 /24940Y Primary Voltage KVA ABCDEWgt Ship Wgt OIL Qty 10 38 17 20 13.25 11.25 205 217 11 15 38 17 20 13.25 11.25 245 256 11 25 46 22 24 17.5 11.25 455 470 29 37.5 46 22 24 17.5 11.25 505 526 28 50 51 25 27 20 11.25 730 755 41 75 52 25 28 20 23.25 910 936 38 100 56 27 28 20 23.25 985 1025 46 167 56 38 33 24 23.25 1430 1495 70 250 68 38 33 24 24 1865 1930 91 333 61 42 35 24 24 1970 2041 75 500 72 45 39 27 36 2960 3055 121 All Approximate Dimensions shown reference designs with +/- 2.5% Taps POWER PARTNERS 5 Transformer Protection Package for Overhead Distribution Transformers Power Partners offers four basic transformer types: S, SP, Self-Protected “CSP ®” Transformers CP and CSP ®. Together they represent a wide range of The CSP ® coordinated protection package is available as protective capabilities to meet nearly every application. an option on Power Partners overhead distribution trans - For transformers supplied with overcurrent protection, formers for increased protection against surge currents, the user must assure coordination with system protec - short circuits, and overloads. tive devices. Failure to do so will defeat the purpose of such protection. ® Type CSP Type S Features 1. Protective Link Conventional “S” Transformers a) Removes an internally-faulted transformer from This type transformer contains no protection equipment. the primary line. Therefore, lightning, fault and overload protection for b) Operates at 8 to 14 times normal full load current.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    19 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us