LC-MS Innovations: Review of the Technology and Its Advancements

LC-MS Innovations: Review of the Technology and Its Advancements

WHITE PAPER 65145 LC-MS innovations: review of the technology and its advancements Triple quadrupole (QqQ) and Orbitrap-based mass spectrometry technology—choose the right tools for the right trade Author Summary Debadeep Bhattacharyya, Separation technologies, such as liquid chromatography (LC) coupled with Thermo Fisher Scientific, Boston, MA mass spectrometry (MS), are the principal analysis techniques for identifying and quantifying compounds. The ever-increasing demands of modern analysts, Keywords and novel application workflows, have led to the evolution of these instruments. TSQ Fortis, TSQ Altis, TSQ Quantis, When working with complex matrices, triple quadrupole (QqQ) mass Q Exactive Focus Orbitrap, mass spectrometers have established popularity in quantifying analytes at very low spectrometer, Triple Quadrupole MS, detection limits, with specificity and selectivity. Similarly, high-resolution QqQ, High-resolution accurate-mass accurate-mass (HRAM) spectrometers are also known for their outstanding (HRAM) spectrometers selectivity, specificity, and sensitivity when working with challenging matrices. The ability to develop robust and reliable assays with both QqQ and HRAM systems has made these technologies a common choice when it comes to quantitation of analytes in complex matrices. Both technologies offer unique advantages, enabling supreme confidence in the quantitation of a variety of molecule types. Regardless of the chosen technology, we are still facing challenges in the development of robust and appropriate methods, the time taken to become operational, reducing cost per sample, etc. This paper outlines the latest developments with both of these MS techniques and highlights the suitability of each for varying application demands and challenges. What is triple quadrupole MS? In mass spectrometry, quadrupoles are responsible for Fortunately, quadrupoles lend themselves to being filtering ions by applying an oscillating electric field that coupled to one another. Despite being known as ‘triple results in the separation of ions from the sample based quadrupole’ instruments, a QqQ system is actually a on their mass-to-charge ratios (m/z). In this way, single tandem quadrupole mass analyzer. The two quadrupole quadrupole mass spectrometers are adept at selecting a mass analyzers are referred to as Q1 and Q3 with q2 specific mass from a sample. However, they might have acting not as an analyzer, but as a collision cell. When some limitations when required to differentiate between the triple quadrupole is operating, a precursor ion is molecules that have the same mass, or discerning selected in Q1 along with other isobaric masses. The between analytes in a complicated mixture, or in a molecular ions then enter the q2 collision cell, along with complex matrix. When dealing with a complex sample neutral gas molecules such as helium or nitrogen. The matrix, isobaric masses that are produced in the source selected masses are then bombarded with the gas until could also be selected along with the ion of interest and they fragment to produce unique masses from each of enter the analyzer. This will modify the data collected, the ions selected in Q1. This is known as collision- alter the peak shape, and affect the validity of the results. induced dissociation (CID). The mass or masses of This collection of unwanted isobars is referred to as interest are then selected in Q3, and the other interfering similar mechanism interference. It broadens the masses that were produced are discarded. This method chromatogram peaks to resolutions that would not be yields greater structural information, along with enhanced acceptable across almost every type of application. selectivity and sensitivity, and ensures a sharp, clean signal. Figure 1 indicates this process when used in conjunction with an LC-MS. Figure 1. A schematic of a triple quadrupole. 2 Advantages of triple quadrupole MS Triple quadrupole setups can be used in scanning or procedure can be avoided by using a triple quadrupole filtering mode depending on the analysis requirements. instrument which allows for automated optimization of A full scan mass spectrum is likely to only be used for selected-reaction monitoring methods. For example, the qualitative analysis, because in full scan mode, Thermo Scientific XCalibur software of the TSQ Altis quadrupoles rarely offer the same sensitivity as that in LC-MS/MS and TSQ Quantis LC-MS/MS systems ensures selected-ion monitoring (SIM) mode. If quantitative studies faster method development and optimization of a host of are to be undertaken, the quadrupoles will have to work molecule types in variable and complex matrices. in filtering mode. The most selective mode that a single quadrupole MS can operate is SIM, where the quadrupole What is high resolution Orbitrap MS? functions at a fixed voltage, meaning that only an ion with Another option in state-of-the-art MS is to link a a specific mass-to-charge ratio will be selected, and all quadrupole analyzer to a Thermo Scientific Orbitrap ions with a different m/z will be filtered out. mass analyzer, to achieve high resolution spectra. Orbitrap mass analyzer technology is capable of screening, An advantage of triple quadrupole MS is that it can be confirming, and quantifying all in the same run, and operated in selected-reaction monitoring (SRM) mode for allows for improved resolution and selectivity of the quantitative analysis. In SRM mode, the tandem compounds. In this way, Orbitrap mass analyzer quadrupoles act as a double mass filter, which in turn instruments have advantages over alternative high dramatically reduces background noise, and increases resolution technologies (such as Quadrupole Time-of- the selectivity of the instrument. In addition, some of the Flight (QTOF technologies)) in that they can identify all more advanced triple quadrupoles offer high resolution compounds in a complete matrix, achieve accurate selected-reaction monitoring (H-SRM), in which the Q1 quantitation with excellent dynamic range, without and Q3 width can be varied between unit resolution detector saturation and experimental flexibility1. (0.7 Da FWHM) and a much lower width (0.2 Da FWHM). Orbitrap mass analyzers are comprised of two outer The ability to modify the Q1 and Q3 widths offers electrodes wrapped around a central electrode and in this additional selectivity while also increasing the signal-to- configuration, it acts as both a mass analyzer and noise ratio. Thermo Scientific TSQ Altis triple detector. When ions enter the Orbitrap mass analyzer quadrupole MS and Thermo Scientific TSQ Quantis they are captured by a process called ‘electrodynamic triple quadrupole MS systems are designed with this squeezing’. These captured ions then revolve around the unique H-SRM feature, along with extremely fast scan Orbitrap mass analyzer’s central electrode and between speeds (600 SRMs/s). Both the TSQ Altis MS and TSQ the two outer electrodes. The charge differences of the Quantis MS systems are equipped with segmented ions generated mean that they will oscillate at different quadrupoles for better ion transmission and management. rates which results in mass separation. The features and benefits found in triple quadrupoles The unique high resolution that is achievable by the allow for faster, more efficient, and more robust method Orbitrap mass analyzer is due to the nanometer-range development, while ensuring increased throughput. With accuracy of the electrodes, the high voltage that is their higher sensitivity, triple quadrupoles allow for supplied, and the mass-to-charge measurements that can increased confidence in quantitation for multiple be measured as a function of the frequency of the ion’s molecules in a variety of complex matrices. SRM based oscillation. Most analyte compounds will contain certain quantitation is extremely sensitive, as well as being amounts of isotopic elements, for example C12, C13, C14. reliable and suitable for analyzing large sample numbers. The Orbitrap mass analyzer system can resolve all these In addition, SRM with short dwell times allows for the different isotopes and differentiate between them, giving detection of many different transitions. distinct peaks or spectra related to that compound of interest. Figure 2 indicates an Orbitrap mass analyzer The first step of any MS experiment is to produce the setup, with the Thermo Scientific Q Exactive Focus selected reaction ions. This involves setting up experiments hybrid quadrupole-Orbitrap MS system as an example. to identify precursor masses and product masses, as well as optimizing the collision energies, which is a lengthy and laborious process. This time-consuming 3 C-Trap Quadrupole Mass Filter HCD Cell Parallel filling m/z (50–2000) MS/MS and detection Precursor selection Bent Flatapole RF Lens Orbitrap Mass Analyzer Figure 2. Orbitrap mass analyzer and Detector setup—performance and capabilities Resolution 70K of the Q Exactive Focus MS system. Mass accuracy better than 1 ppm Ion Source Advantages of high resolution Orbitrap MS High resolution setups based on Orbitrap mass analyzer detection, a high resolution system can look at multiple technology can collect data in full scan, MS/MS, SIM, or peaks at the same time, and give multiple spectra related parallel reaction monitoring (PRM) modes. PRM operates to different compounds mixed in the sample. High by performing a full scan of each transition by a precursor resolution is therefore very important, since it enables ion, in other words, parallel monitoring

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us