'Adlux Medicity and Convention Centre'

'Adlux Medicity and Convention Centre'

FORM-1 FOR ENVIRONMENTAL CLEARANCE FOR THE PROPOSED EXPANSION OF THE BUILDING PROJECT ‘ADLUX MEDICITY AND CONVENTION CENTRE’ AT KARUKUTTY VILLAGE ALUVA TALUK ERNAKULAM DISTRICT KERALA BY ADLUX MEDICITY & CONVENTION CENTRE PVT. LTD ADLUX JUNCTION,KARUKUTTY P O KARUKUTTY VILLAGE, ALUVA TALUK, ANGAMALY, ERNAKULAM, KERALA PIN 683576 (I) Basic Information S Item Details No. 1. Name of the project/s Proposed expansion with the addition of Hotel, 250 Bed Hospital, Nursing College, Hostel & Other Buildings for Adlux Medicity & Convention Centre Pvt. Ltd at Karukutty, Angamaly, Ernakulam. 2. S.No. in the schedule 8 (a) 3. Proposed capacity/area/length/tonnage to Total Plot area : 170597 m2 be handled/ command area/lease Total Built up area for the : 47542.9 m2 area/number of wells to be drilled proposed expansion Built up area of the proposed : expansion, which is already 19955 m2 constructed, but not yet operational Total Green area for the : 34119.4 m2 entire campus FAR : 0.43 Coverage : 19.29% The detailed area statement for the proposed expansion is as follows: Building Block Name Built-up area [m2] Hospital Building already 19955 constructed, but not yet operational Additional Built-up area proposed 16419.79 for the Hospital building Hotel building 2945.72 Nursing college 3204.05 Hostel buildings 3907.16 Residential quarters 710.78 Service Block 400.4 Total Built-up Area of the 47542.9 proposed expansion 4. New/Expansion/Modernization Expansion 5. Existing Capacity/Area etc. Total Plot area 170597 m2 Existing Built up area 25836.78 m2 …….(A) Built up area constructed before 2006 EIA notification and hence 18450.02 m2…….(B) exempted from requirement of EC Built up area of 47542.9 m2…….(C) proposed expansion Built up area of proposed expansion, exempted from EC, by MoEF & CC as per 7111.21 m2…….(D) Gazetted Notification dated 22-12-2014, as these part of educational institutions Hence total built up area 73379.68 m2……. after the proposed (A+C) expansion Total built up area 47818.45 m2…(A- requiring EC for the B+C-D) proposed expansion 6. Category of Project i.e.’A’ or ‘B’ Category B (B2) 7. Does it attract the general Not Applicable condition? If yes, please specify. 8. Does it attract the specific Not Applicable condition? If yes, please specify 9. Location Karukutty Village, Aluva Taluk, Ernakulam District, Kerala State Re-Survey No. 35/2 Village Karukutty Tehsil Aluva District Ernakulam State Kerala 10. Nearest railway station/airport Karukutty railway Station : 1.1 km along with distance in kms Cochin International Airport : 12.4 km 11. Nearest Town, city, District Angamaly : 4.9 km Headquarters along with distance District Headquarters, Kakkanad : 31 km in kms. 12. Village Panchayats, Zilla Karukutty Village Office Parishad., Municipal Railway Station Rd, Karukutty, Corporation, Local body Kerala- 683576 (complete postal addresses with Ph: 0484-2612535 telephone nos. to be given Karukutty Grama Panchayat Office National Highway 544, Karukutty, Kerala- 683576 Ph: 0484 245 2231 13. Name of the applicant Adlux Medicity & Convention Centre Pvt. Ltd 14. Registered address Adlux Junction Karukutty P.O, Angamaly Ernakulam District , Kerala 15. Address for correspondence: Dr. Sujith Sudheesan Director Adlux Medicity & Convention Centre Pvt. Ltd Adlux Junction Karukutty P.O, Angamaly Ernakulam District, Kerala Name Dr. Sujith Sudheesan Designation(Owner/Partner/CEO Director, Adlux Medicity & Convention Centre Pvt. ) Ltd Address Karukutty P.O, Angamaly Ernakulam District Kerala Pin Code 683 576 E-mail [email protected] Telephone No. 9847364400 Fax No. - 16. Details of Alternative Sites Not applicable. examined, if any. Location of The proposed project is the expansion of buildings these sites should be shown on a within the same campus Toposheet. 17. Interlinked Projects No 18. Whether separate application of Not Applicable interlinked project has been submitted? 19. If yes, date of submission Not Applicable 20. If no, reason Not Applicable 21. Whether the proposal involves Not Applicable approval/clearance under: if yes, details of the same and their status to be given (a)The Forest (Conservation) Nearest notified Forest area at an aerial distance of 13 Act,1980? km (b) The Wildlife (Protection) Nearest Sanctuary (Chimmini Wildlife Sanctuary) Act,1972? situated at an aerial distance of 24 km (c) The C.R.Z.Notification,1991? The nearest CRZ area (Chalakudi River) is situated at an aerial distance of 3.7 km 22. Whether there is any No Government Order/Policy relevant/relating to the site? 23. Forest land involved (hectares) No 24. Whether there is any litigation No pending against the project and / or land in which the project is propose to be set up? (a) Name of the Court (b) Case No. (c) Orders/directions of the Court, if any and its relevance with the proposed project (II) Activity 1. Construction, operation or decommissioning of the Project involving actions, which will cause physical changes in the locality (topography, land use, changes in water bodies, etc.) Details thereof (with approximate quantities /rates, wherever possible) S.No. Information/Checklist Yes/No with source of information data confirmation 1.1 Permanent or temporary change No The site is already developed with in land use, land cover or Conventional centre, exhibition centre, topography including increase hospital building, quarters, other utility in intensity of land use (with buildings and a temple. A few of the old respect to local land use plan) buildings will be demolished. Eight new buildings are proposed to be constructed, which include a hotel building, nursing college, hostels and quarters. Of these Nursing colleges and hostels are not under the purview of EIA. 1.2 Clearance of existing land, Yes Clearance of few garden trees will be vegetation and buildings? compensated with the plantation of more native species in the green belt. 1.3 Creation of new land uses? No A few of the old buildings will be demolished for the proposed expansion with properly planned green belt and landscape. 1.4 Pre-construction investigations Yes Geotechnical Investigation has been e.g. bore houses, soil testing? carried out and the report is attached as Annexure 1.5 Construction works? Yes Construction of hotel, nursing college, hostels and quarters. 1.6 Demolition works? Yes Old building structures such as Existing work shed buildings and other few buildings will be demolished. The total built up area of buildings to be demolished is as follows: Building No. Built-up area [m2] 1/642 198.66 1/644 74 1/647 587.57 1/648 372.32 1/651 215.39 Total 1447.94 1.7 Temporary sites used for No No housing for construction workers is construction works or housing of planned as the labourers deployed will be construction workers? accommodated offsite by the contractor. 1.8 Above ground buildings, Yes The quantity of earth cutting involved = structures or 3000 m3 earthworks including linear The earth obtained from cutting shall be structures, cut and utilized for road laying and landscaping. fill or excavations Hence cutting and filing shall be equalized and no earth shall be taken out of the campus. 1.9 Underground works including No Not applicable mining or tunneling? 1.10 Reclamation works? No Not involved 1.11 Dredging? No Not involved 1.12 Offshore structures? No Not involved 1.13 Production and manufacturing No Not involved processes? 1.14 Facilities for storage of goods or Yes Temporary storage facilities will be materials? created to store the raw materials for construction. 1.15 Facilities for treatment or Yes Liquid Waste disposal of solid waste or liquid ETP for treatment of wastewater. In effluents? the ETP, wastewater is treated using MBBR. Treated wastewater will be recycled and used for flushing, gardening and HVAC, excess treated wastewater shall be polished through engineered subsurface flow constructed wetland and discharged to the drain. The sludge from STP will be dried, composted and used as manure Solid Waste The solid waste generated shall be segregated at source to organics and recyclables All the organic solid waste generated will be treated onsite in a biogas plant All the recyclable solid waste shall be stored and sold to recyclers Biomedical Waste The biomedical waste is being segregated at source by providing appropriate colour coded bins/ containers as per the colour coding provided in the Bio-Medical Waste Management Rules 2016. The Bio- medical waste from the hospital buildings shall be outsourced through a Kerala State Pollution Control Board Authorized agency IMAGE. 1.16 Facilities for long term housing No All the operational workers will be from of operational workers? the district itself and no housing/ accommodation will be provided to them. 1.17 New road, rail or sea traffic No Not required during construction or operation? 1.18 New road, rail, air waterborne or No No new transport infrastructure is other transport infrastructure required. The existing road has the including new or altered routes capacity to cater for the additional traffic and stations, ports, airports etc? 1.19 Closure or diversion of existing No There will not be any closure or diversion transport routes or infrastructure of existing transport routes or leading to changes in traffic infrastructure leading to changes in traffic movements movements? 1.20 New or diverted transmission No Not Applicable lines or pipelines? 1.21 Impoundment, damming, No There will not be any impoundment, culverting, realignment or other damming, culverting, realignment or other changes to the hydrology of changes to the hydrology of water courses or aquifers watercourses or aquifers? 1.22 Stream crossings? No There are no stream crossings 1.23 Abstraction or transfers of water Yes Water is extracted from the one existing form ground or surface waters? open well and bore well and 3 proposed bore wells at the site.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    27 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us