Innovation that Endures www.fi relite.com Addressable Fire Alarm Control Panels MS-9050UD, MS-9200UDLS and MS-9600LS/MS-9600UDLS Addressability Within Reach Fire-Lite Alarms’ addressable product offering includes three Fire MS-9050UD Alarm control panels that vary in size and capability to meet a wide • Single SLC that provides support for 50 addressable devices (any combination range of needs, while offering superior value and fl exibility. Our ad- of addressable detectors and modules) dressable product line offers ease of installation and programming, • Integrated DACT for off-premises monitoring addressable point identifi cation, built-in digital communication, and • Annunciator bus supports up to 8 devices, including ANN-80 LCD remote NAC synchronization. Our super fast LiteSpeedTM protocol ensures that annunciator, remote serial or parallel printer gateway, and LED graphic annunciator the safety and security of your building and its occupants are always • Auto programming feature quickly confi gures detectors and modules met with the utmost urgency. Fire-Lite’s addressable product line sets • Two programmable Class B / A notifi cation appliance circuits (NAC) the benchmark for Fire protection with its innovative, non-proprietary, cost effective products. MS-9200UDLS Included features on our most popular addressable panels: • Single SLC provides support for 198 addressable devices • Ability to connect devices via unshielded “fi re” wire up to 10,000 • LiteSpeed protocol for SLC communication polls 10 devices at a time and operates feet, allowing for easier retrofi ts and less install time on standard, unshielded wire • Autoprogram locates and programs the panel for each device • Built-in digital communicator for off premises monitoring and remote up/download and ensures correct addressing and device type • Four programmable Class B / A notifi cation appliance circuits (NAC) • All electronics mounted on chassis, which can be changed • 3 amp total shared power supply expandable to 6 amps of notifi cation power by removing only two nuts, for faster change-outs and easier with optional transformer upgrades • Supports up to 32 optional LCD-80F or ACS LED annunciators • Notifi cation appliance circuits have built-in synch for the industry’s leading manufacturers including System Sensor®, Wheelock® and Gentex® MS-9600LS/MS-9600UDLS • Compatibility with Fire-Lite’s Internet/Fire Communicators, • Up to 159 detectors and 159 control/monitor modules (total of 318 devices) per SLC for communicating alarms over WAN or LAN to the central station (636 with SLC-2LS option card) • LiteSpeed protocol for SLC communication polls 10 devices at a time and operates on standard, unshielded wire • Autoprogrammable function reduces installation time • Advanced Fire Technology includes sensitivity testing and automatic drift compensation • Four programmable Class B / Two Class A notifi cation appliance circuits (NAC) SWIFT® Wireless Devices SWIFT wireless addressable devices provide secure, reliable communication to the SWIFT Devices Fire Alarm Control Panel (FACP) across a Class A mesh network. Great for applications The SWIFT line offers a variety of device options including where it is costly, obtrusive, or possibly dangerous to use traditional wired devices. photoelectric, photo/thermal, standard and rate of rise W-GATE Gateway heat detectors as well as a relay and monitor module. Using the SWIFT gateway, the FACP views the SWIFT wireless ANN-80W Annunciator device as another addressable device on the system providing Fire-Lite fi re alarm control panels require W-DIS-D similar detection functions and outputs as a wired counterpart. and ANN-80W to display wireless specifi c messages. MS-9200UDLS Fire Alarm Control Panel Applications ECC-50/100 Primary Operator Console ECC-FFT Fire Fighter Telephone SD355 SPSRL Series Photo Detector Speaker/Strobe ECC-50DA/ECC-50BDA/ECC-125DA Distributed Audio Amplifi ers IPGSM-4G ECC-LOC Fire Communicator Local Operator AD355 Console Adapt Detector SPRL Speaker ECC-RM SPCWL Remote Microphone ECC-RPU ANN-80 Series Speaker H355/H355R/H355T Remote Paging Unit Annunciator Heat Detector P2RL Strobe MDF-300 Dual Monitor Module ANN-80-W* Annunciator Power Supply P2RH-LF Low Frequency FCPS-24FS6 Notifi cation FCPS-24FS8 SD355T Devices *Installed next to FACP Photo/Thermal Detector B200SR-LF W-GATE W-DIS-D Gateway Display Driver W-SD355T MMF-300 W-SD355 Photo/Thermal W-CRF Monitor Module Photo Detector Detector Relay Module W-H355R Multi-Modules Heat Detector W-MMF • CRF-300-6 Six-Relay Control Module Monitor Module • CMF-300-6 Six-Circuit Supervised Control Module • MMF-302-6 Six-Zone Interface Module W-H355 • MMF-300-10 Ten Input Monitor Module Heat Detector • ISO-6 Six Output Isolator Module SLC Loop MMF-302 2-Wire Detector Monitor Module Beam 355 Beam Detector CDRM-300 Dual Relay/ D355PL Monitor Module Duct Detector BG-12LX Addressable www.fi relite.com Manual Pull Station Emergency Voice Evacuation / Mass Notifi cation Emergency Communications/Mass Notifi cation is about delivering critical messages when they matter most. Our Emergency Command Center (ECC) leverages advanced technology and our 60+ years of life safety dedication and unrestrictive, non-proprietary products. The ECC is ideal for any stand-alone building that needs a fl exible, multi-zoned and highly confi gurable fi re evacuation and mass notifi cation system that’s easy to install and maintain. ECC-50/100 ECC-LOC Primary Operator Console Local Operator Console • Seamless integration and control when connected to select Fire-Lite • Provides a complete control and interface like the ECC-50/100 addressable panels through the ANN/ACS communication bus • Includes built in microphone for ALL CALL paging along with message • May be used with any UL-listed Fire Alarm control panels. (Messages and zone control can be initiated by using a dry contact or via a Fire Alarm NAC circuit) • A maximum of eight ECC-LOCs (or combination of other remote display consoles) • Includes a single 25V, 50 watt speaker circuit. (Upgradable to 100 watts and two speaker circuits with optional amplifi er) ECC-RPU • Speaker circuits are expandable by up to eight (8) outputs (With an optional Remote Page Unit ECC-CE6 module) • Includes built-in microphone for ALL CALL paging along with message control • Includes 14 pre-recorded messages that are fi eld programmable for • A maximum of eight ECC-RPUs (or combination of other remote display consoles) up to 60 seconds of message playback • Additional 9th button can be used to activate an optional monitor module that • Built in 2 Amp NAC output with sync generator can be mounted inside the cabinet for applications such as HVAC shutdown • 8 Command Input Circuits that can be used to activate messages 1 to 8 • Optional amplifi er can be confi gured as a backup in the event the primary ECC-RM amplifi er fails. Amplifi ers are independently powered to eliminate system Remote Microphone interruption during a short circuit condition • Includes built-in microphone for ALL CALL paging over available speaker zones • Optional transformer conversion module available for 70.7V speaker operation • A maximum of eight ECC-RMs (or combination of other remote display consoles) • Supports charging up to 26AH batteries ECC-FFT ECC-50DA / ECC-50BDA / ECC-125DA Fire Fighter Telephone Distributed Audio Amplifi ers • Provides supervision, annunciation and control for up to 24 remote • Externally mounted amplifi ers provide an additional 50 or 125 watts telephone handsets of addressable audio power when connected to the ECC-50/100 • Built-in auto-program feature for quick installation • Up to eight distributed amplifi ers can be connected to the ECC-50/100 • Can be wired for class A (Style 6 or Style 7) or class B (Style 4) confi guration for a total of 1100 watts of audio power • Can be confi gured for Multi-Phone Jack Audio Circuit supervision • Includes four built-in speaker circuits which are expandable to eight circuits • Allows simultaneous operation of up to 10 fi refi ghter remote handsets with an optional ECC-CE4 module (A maximum of 24 audio circuits) • Speaker output voltage is fi eld confi gurable on ECC-50DA for either 25 volts or 70.7 volts of operation • Includes a built-in power supply and backup battery charger • ECC-50BDA provides 50W of power with 50W as back-up. It can also provide 100W of power (100W primary and 50W of back-up power requires ECC-50WBU) ECC-RTZM Remote Telephone Zone Module • Module allows authorized personal access to the system via any telephone • Remote users have the ability to initiate pre-recorded messages or make live announcements Conventional Fire Control Panels Fire-Lite’s 24 Volt conventional fi re alarm control panels bring the latest in microprocessor technology to conventional fi re controls and are easy- to-install, program and operate. With two-zone, four-zone, fi ve-zone and ten-zone confi gurations, these units offer a variety of options to meet most local, state and national requirements. MS-2 MS-5UD • Two initiating zones compatible with 2- and 4-wire • Five-zone Style B (Class B) or Five-zone Style D (Class A) with optional module smoke detectors, one zone programmable for combo, • Four NAC Circuits Style Y (Class B) or Four NAC Circuits Style Z (Class A) with supervisory and waterfl ow optional modules • One Notifi cation Appliance Circuit (NAC) with built-in • Built-in NAC synchronization for System Sensor®, Wheelock®, Gentex®, horn/strobe synchronization for System Sensor®, Faraday® and Amseco® devices Wheelock® or Gentex® with selectable
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages8 Page
-
File Size-