Optimization of a Flocculation-Sedimentation

Optimization of a Flocculation-Sedimentation

Optimization of a flocculation-sedimentation Zweckverband treatment plant with lamellas (FLUENT) Landeswasser- versorgung Dipl.-Ing. Marian Brenda Dresden-Rossendorf Backround Information The Zweckverband Landeswasserversorgung provides drinking water for the north-east of Baden-Württemberg and parts of Stuttgart Water delivery 90 Mio m³/a Within the water treatment plant of Langenau raw water from the river Danube is purified Flow diagram of the flocculation-sedimentation Flocculation Aid Lime Milk Clear Water Flocculant Raw Water (Danube) Sludge Pre-Mixer Accelator Overview Capacity 400 to 800 l/s Diameter Accelator: 36 m Height Accelator: 9,5 m Measuring the settling velocity During the settling test the sludge level is measured over the time Within the first minutes linear settling takes place Thereafter hindered settling takes place Within the phase of linear settling the Settling curve concentration and settling velocity is 1000 constant Æ settling velocity for a 900 certain concentration 800 linear settling 700 Relatively easy to measure (standard 600 evel (ml/l) evel 500 hindered test DIN 38 414) 400 settling Sludge l 300 Height of the sludge level after 30 200 Minutes is called sludge volume 100 0 (important parameter in waste water 0 5 10 15 20 25 30 treatment plants) Time (min) Settling velocity depending on concentration Settling velocity depending on concentration 0,003 0,0025 0,002 0,0015 0,001 0,0005 Settling velocity [m/s] 0 01234 Concentratin [g/l] Rheology Non Newton fluid Shear thinning Viscosity depending on concentration Flow Curve 0,07 19,4 g/l 0,06 0,05 0,04 14,8 g/l 0,03 12,6 g/l 0,02 Shear Stress[Pa] 10,8 g/l 0,01 7,2 g/l 0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 Shear Rate [1/s] Validation of sludge modell The settling test was simulated with FLUENT The results were compared with the measurements Simulation and measurements fit quite well according to sludge volume Sludge Volume - Concentration 450 400 350 l/l) 300 250 Accelator 200 Simulation 150 100 Sludge Volume (m Volume Sludge 50 0 01234 Concentration (g/l) The sludge model Sludge is modeled with a „user defined scalar“ (uds) and contains of following components: Convection Settling velocity depends on concentration Diffusion Turbulent diffusion depends on density gradients („full buoyancy effect“) Viscosity Viscosity depends on concentration and shear rate Density Density depends on concentration The sludge model Components which will be developed in further research projects: Convection Settling velocity, regarding low concentrations Viscosity Viscosity of low concentrated sludge, Yield stress, Time dependent viscosity Parameter Mathematical Optimization of model parameters Identification Multiphase or Singlephase? Even though the sludge model is a singlephase approach it interacts intensively with the flow regime Advantage: no particle size of flocs required to determine the settling velocity Modelling of sludge with multiphase approachs also possible, but require complex models to describe the variation and distribution of particle sizes Singlephase approach requires less computational efforts To model the sedimentation process a relatively long flow time is required. Example for this case: 12 cores, 8 Mio cells, 3.600 seconds flow time, ~30.000 iterations à 20 seconds/iter Æ 1 week per calculation 4 Variations of lamella clarifier: different slope and distance between lamellas (5 or 10cm) Geometry Grid: between 6 and 13 Mio cells Scheme Inlet Channel Outlet Lamella clarifier Stirrer (C) by Dr.-Ing. Alexander Sonnenburg Pathlines Velocity Flow regime Sludge concentration Density Coupling turbulent viscosity - diffusion coefficient (Schmidt Number 1.3) Molecular viscosity Molecular viscosity vs. turbulent viscosity in the sedimentation zone Grid effects 13 cell rows between lamellas: backflow of highly concentrated sludge 7 cell rows between lamellas: no backflow of highly concentrated sludge Results Results can be seen only in comparison between the simulations. For validation on the real plant the lamella clarifier has to be built and measurements have to be taken to compare simulation with reality. Sludge concentration at the outlet of lamella clarifier are 2 (10cm distance) to 5 (5cm distance) orders of magnitude lower than without The slope has no significant effect on the flow regime or the outlet concentration The grid quality is very important for the results Further research is necessary to improve the sludge model and to verify it with the real plant Thank you for your attention Zweckverband Landeswasser- versorgung.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    26 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us