Optical Modulation Analyzer

Optical Modulation Analyzer

Optical Modulation Analyzer The Highest Performing OMA in the World Teledyne LeCroys’ LabMaster 10 Zi Oscilloscope | Coherent Solutions’ IQScope-RT KEY FEATURES · Up to 70 GHz Coherent Receiver bandwidth · Up to 130 GBaud detectable · Real-time acquisition for testing of long-haul optical channels · Built-in dispersion compensation, polarization de-multiplexing and carrier recovery algorithms with exhaustive analytical views and parameters · User algorithm development with MATLAB™ · Supports DP-QPSK, DP-16-QAM, a variety of other PSK & in partnership with QAM formats and custom formats · The most seamlessly integrated OMA system on the market Providing Complete Solutions to R&D Engineers in Coherent Optical Communications IQPulse Pattern Generator RF electrical signal generation of high bandwidth PRBS signals Options available: IQPPG - 4 channel IQPPG - 2 channel IQTransmitter Generation of optical signals encoded with high bandwidth complex modulation formats - DPQPSK, 16QAM and 64QAM Options available: IQTransmitter Full Dual-Polarization IQTransmitter Emulated Dual-Polarization YOUR FIBER NETWORK THE HIGHEST PERFORMING OPTICAL MODULATION ANALYZER ON THE MARKET IQScope-RT ‘Gold Standard’ Coherent optical receiver with up to 70GHz signal bandwidth TM Optical LINQ OPTICAL-LINQ Optical modulation analyzer software Teledyne LeCroys’ LabMaster 10Zi Real-time oscilloscope Options available: 4 channel at 36GHz 4 channel at 65GHz The World’s Highest Performing Optical Modulation Analyzer System The IQScope-RT Coherent Optical Receiver with LabMaster real-time oscilloscopes provides up to 65 GHz of bandwidth for optical modulation analysis of dual-polarized signals up to 130 Gbaud. That’s the highest bandwidth commercial capability in the world. The combined system from Coherent Solutions and Seamless Multi-Module Configuration Teledyne LeCroy is the market leader in OMA solutions; ChannelSync™ architecture utilizes a single 10 GHz providing ground breaking oscilloscope with a seamlessly distributed clock to precisely align all acquisition modules integrated, intuitive interface and a uniquely scalable for lowest inter-channel jitter and the highest confidence format that delivers unrivalled performance. You get full in results. characterization of your optical signal’s true performance - Out of the Box. Unmatched Software Integration Optical LINQ, the OMA Signal Analysis software, runs on Industry Leading Bandwidth and the LabMaster 10 Zi and is fully integrated into the DSO Sample Rate software giving you a seamless, intuitive interface. 70 GHz Coherent Optical Receiver bandwidth provides up to 130 GBaud symbol rate analysis when used with the 65 Smart and Dynamic Calibration GHz LabMaster 10-65 Zi acquisition modules. The IQScope-RT provides optimized signal fidelity and adaptive self-calibration allowing the receiver to be Modular Scalable Architecture disconnected and reconnected without factory calibration. Upgradable oscilloscope bandwidth (20 GHz - 65 GHz) and channel count (4 in a single unit and up to 80 with Watch the short features video here! additional acquisition modules). Choose the functionality you need now and upgrade later. Real-time OMA Solutions 1 Introducing Coherent Solutions' IQScope-RT the World's Leading Coherent Receiver The IQScope-RT Coherent Optical Receiver brings optical modulation analysis to the Teledyne LeCroy LabMaster 10 Zi oscilloscope. As a calibrated reference receiver, the IQScope-RT performs heterodyne detection on both orthogonal polarization components of the optical field. Up to 70 GHz electrical outputs of X and Y Modulated optical input: C and L - Band polarization in-phase and quadrature signals Laser wavelength/frequency and power Use the built-in local oscillator or your own adjustable via front-panel interface or from narrow-linewidth local oscillator the oscilloscope with 100 MHz resolution C, L or C and L - Band; optional Real-time OMA Solutions 3 Introducing Teledyne LeCroy LabMaster 10 Zi the World's Leading Real-time Oscilloscope 1. World’s Highest Performing Real-Time Oscilloscope - 65 GHz bandwidth, (5.2 ps risetime ), 20 - 80% 5 160 GS/s sample rate, up to 80 channels, 8 up to 1024 Mpts of analysis memory 9 11 12 2. Modular - start with four channels and grow your system over time. Spread out your investment as funds permit 4 10 3. Wide bandwidth upgrade range (25 - 65 GHz) 1 provides investment protection 7 4. ChannelSync™ architecture utilizes a 10 GHz 3 distributed clock for precise alignment of all 2 acquisition systems 6 5. Single trigger circuit for all modules eliminates additive trigger jitter that occurs with 10 MHz clocking and trigger synchronization of multiple conventional oscilloscopes 6. Simple - connect and acquire - Teledyne LeCroy has done the hard work for you 7. 325 MB/s data transfer rate from the LabMaster to a separate PC with Teledyne LeCroy Serial Interface Bus (LSIB) option 8. Server-class multi-core processor combines with X-Stream II streaming architecture for fast acquisition and analysis - 33.6 GHz effective CPU clock rate and 24 GB of RAM standard (expandable to 192 GB) 9. Utilize the built-in 15.3” widescreen (16 x 9) high resolution WXGA color touch screen display - or connect your own with up to WQXGA 2560 x 1600 pixel resolution 10. Highly stable timebase (50 fsrms) over long acquisitions, low Jitter Measurement and Rj noise floor 11. Deepest standard toolbox with more measurements, more math, more power 12. 14.1 Gb/s Serial Trigger Option - 80-bit NRZ, 8b/10b and 64b/66b triggering 4 Coherent Solutions Ultimate Electrical Signal Analysis Solution High Bandwidth, High Precision Up to 325 MB/s Data Transfer LabMaster 10 Zi is the world’s highest bandwidth Teledyne LeCroy’s Serial Interface Bus (LSIB) to allow (65 GHz) real time oscilloscope. The modular design acquired data to be transferred to another computer allows more channels with better performance, and at speeds up to 325 MB/s to leverage the LabMaster permits simple and easy upgrades. Yet, the operation oscilloscope solely as a data acquisition device with is the same as any other oscilloscope - there is a single fast offload of acquired data to another CPU for 10 GHz timebase clock, trigger circuit, and display further analysis. for all acquisition modules and channels. Teledyne LeCroy’s ChannelSync™ architecture ensures precise synchronization of all acquisition modules and virtually eliminates jitter between channels for the highest possible phase performance. Complete Customization All configurations of LabMaster 10 Zi support the needs of researchers with complete customization capability through the use of the XDEV software capability. This provides the ability to integrate a MATLAB or other user-generated script into the oscilloscope’s processing stream - ideal for proprietary equalization and compensation algorithms. 16-Channel LabMaster 10 Zi system in OC910 cart SDAIII-CompleteLinQ Teledyne LeCroy’s SDAIII-CompleteLinQ Serial · Data, Crosstalk and Noise Analysis toolset provides unique capabilities for serial data analysis. It is the only toolset with simultaneous eye, jitter, noise and crosstalk analysis on multiple lanes. SDAIII-CompleteLinQ’s Unique Capabilities: · Four lanes of analysis · Integrated fixture and channel de-embedding/emulation · Simultaneous jitter, noise and eye analysis on four lanes · Multi-block system and crosstalk modeling with VirtualProbe · Extrapolated noise analysis with the new Crosstalk Eye · Transmitter and receiver equalization modeling · Multi-scenario comparisons with the new Reference Lane · LaneScape Comparison Mode Real-time OMA Solutions 5 Possess the Power of Full Signal Characterization It is generally accepted that EVM is a representation of the overall signal quality. However, EVM is calculated from constellation points sampled at the center of symbol and often fails to represent what happens during symbol transitions. Symbol transitions or trajectories measured with sufficient analyzer bandwidth can reveal transmitter impairments such as IQ data skew, receiver channel skew, pattern dependent jitter, modulator chirp and more. Having an OMA system with a high bandwidth gives you the power to fully characterize and troubleshoot your transmitter. 32 GBaud QPSK - Modulator Chirp The chirp, or the instantaneous frequency variation over resolve the transition with a high level of accuracy to be time, results in curvy transitions between symbols on able to show the presence of chirp. the I vs. Q plot. An adequate bandwidth is necessary to Measurement with 20 GHz OMA Measurement with 36 GHz OMA Constellation Plot Vector Diagram Vector Diagram EVM = 8.3% EVM = 8.3% EVM = 6.3% 32 GBaud QPSK - IQSkew The IQ skew, or the time delay between RF drive signals signal characterization that can be achieved with a high of I and Q channels, introduce curvature to the inner bandwidth OMA system. transitions of the I vs Q plot. This is another example of Measurement with 20 GHz OMA Measurement with 36 GHz OMA Constellation Plot Vector Diagram Vector Diagram EVM = 7.2% EVM = 7.2% EVM = 5.5% 6 Coherent Solutions 56 GBaud QPSK Source with 40 GHz Bandwidth Not only does the Coherent Solutions IQScope-RT for 32 GBaud signals, it is the only commercial system with the Teledyne LeCroy LabMaster 10 Zi series of capable of revealing a meaningful EVM at 56 GBaud Oscilloscopes provide much greater characterization signals and higher. Measurement with 33 GHz OMA Measurement with 65 GHz OMA EVM = 23% EVM = 5.8% OMA Bandwidth Selection The IQScope-RT OMA system is available in a wide range of bandwidths, from 20 GHz up to 65 GHz, to suit your specific requirements. LabMaster 10 Zi Acquisition Module IQScope-RT Coherent Receiver LabMaster 10-20Zi 20 GHz x 4 CH LabMaster 10-25Zi 25 GHz x 4 CH IQScope-RT-SBW - 37 GHz (min), 42 GHz (typ) LabMaster 10-30Zi 30 GHz x 4 CH Available LabMaster 10-36Zi 36 GHz x 4 CH Bandwidth LabMaster 10-50Zi 50 GHz x 2 CH LabMaster 10-60Zi 60 GHz x 2 CH IQScope-RT-HBW - 65 GHz (min), 70 GHz (typ) LabMaster 10-65Zi 65 GHz x 2 CH Real-time OMA Solutions 7 Target Applications Visibility for Component Testing The amplitude and phase measurement capabilities of Optical-LINQ enable detailed component testing.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    24 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us