T C Cc Cp Ah Pb Rh C0 Ss Os Gd Rs

T C Cc Cp Ah Pb Rh C0 Ss Os Gd Rs

Standard Ductwork Standard Ductwork Fans Sensors and Controllers Schematic Representation Duct air stream size width x depth - Offset (Maximum 15°) - Plug fan - Control wiring Duct S and Drive joint - Pressure regulating valve (PRV) P - Pressure guage 500x400 - HVAC ducting notation and joints - Plate axial fan - Safety valve (SV) 1250L 600L 600L - Rectangular dropping duct section T - Temperature gauge - Drain cock (DC) Duct mez flange joint - Ceiling mounted extract fan Duct segment length P - Pressure sensor - Orifice plate (OP) - Round dropping duct section - Window mounted extract fan Duct construction code if noted (Refer to listing below) - Temperature sensor T - Strainer (STR) 500x400 S/4a - Supply air ducting (SA) - Wall mounted extract fan V - Velocity sensor - Pipe reducer - Rectangular rising duct section H - Humidity sensor - Reduced Pressure Zone / Back flow preventer (RPZ) - Return air ducting (RA) - Wall mounted propeller fan 450x350 R/2 - Humidity high limit sensor - Round rising duct section HH M - Council meter ΔP - Differential pressure sensor - Pressure gauge 500x400 O/1 - Outdoor air ducting (OA) - Ceiling mounted destratification fan - Rectangular duct riser / dropper FS - Flow switch - Binder test point (BT) Grilles and Diffusers 500x400 E/1a - Exhaust air ducting (EA) PS - Pressure switch AVV - Anti-vacuum valve (AVV) - Round duct riser / dropper Air flow direction - Rectangular supply air diffuser (4 way blow) Standard Piping AAV - Automatic air vent (AAV) 500x400 KE/12 - Kitchen exhaust air ducting (KEA) - Plenum box (Internally lined) Pipe nominal bore size Top entry spigot connection Pipe type MBV - Manual bleed valve (MBV) Duct Construction Code (If noted) All pipework drawn to OD size Air flow direction NB200 CHWF 1. Galvanised mild steel - Spigot connection to flexible duct - Floor waste gully (FWG) Max. working pressure: 1=250Pa, 1a=500Pa, 1b=750Pa - Rectangular supply air diffuser (3 way blow) - Piping notation and joints 2. Galvanised mild steel with 25mm internal acoustic insulation. Cushion head box - Pipe cap / end of run Max.working pressure: 2=250Pa, 2a=500Pa, 2b=750Pa Side entry spigot connection Pipe welded joint - 45° Spigot connection to flexible duct Pipe flanged joint 3. Galvanised mild steel with 50mm internal acoustic insulation. Miscellaneous Max. working pressure: 3=250Pa, 3a=500Pa, 3b=750Pa CHWF - Round supply air diffuser - Chilled water flow 4. Galvanised mild steel with 25mm external acoustic insulation. AP - Access panel Max. working pressure: 4=250Pa, 4a=500Pa, 4b=750Pa Ø200 - Flexible duct - Chilled water flow (Single line) 5. Galvanised mild steel with 50mm external acoustic insulation. + HC - Heating coil Max. working pressure: 5=250Pa, 5a=500Pa, 5b=750Pa CHWR - Swirl type supply air diffuser - Chilled water return CC - Cooling coil 6. PVC or similar (rigid) EC - Duct end cap - Max. working pressure: 6=250Pa, 6a=500Pa, 6b=750Pa - Chilled water return (Single line) PTTH - Pitot tube test holes 7. Galvanised mild steel with protective internal coating max. WMS Max. working pressure: 7=250Pa, 7a=500Pa, 7b=750Pa - Wire mesh screen - Linear type supply air diffuser CDWF - Return / Exhaust air flow indicator 8. Aluminium - Condenser water flow Max. working pressure: 8=250Pa, 8a=500Pa, 8b=750Pa - Supply air flow indicator 9. Galvanised mild steel with external fire proofing - Cowl with wire mesh screen - Jet nozzle type supply air diffuser - Condenser water flow (Single line) HVAC Equipment Schedule Abreviations (# = ID number) Max. working pressure: 9=250Pa, 9a=500Pa, 9b=750Pa CDWR AC# - Split system air conditioning unit 10.Proprietary high density sandwich panel - Condenser water return Max. working pressure: 10=250Pa, 10a=500Pa, 10b=750Pa - Cowl (Section) with wire mesh screen - Supply air grille AHU# - Air handling unit 11.Stainless steel - Condenser water return (Single line) BT# - Buffer tank Max. working pressure: 11=250Pa, 11a=500Pa, 11b=750Pa - Return air grille - Round cowl with wire mesh screen LTHWF CT# - Cooling tower 12.Kitchen exhaust - Low temperature hot water flow Max. working pressure: 12=250Pa, 12a=500Pa, 12b=750Pa CH# - Chiller - Outdoor air grille 13.Galvanised mild steel with 12mm internal acoustic insulation. - Bell mouth outlet with wire mesh screen - Low temperature hot water flow (Single line) DA# - Volume control damper Max. working pressure: 13=250Pa, 13a=500Pa, 13b=750Pa - Door grille LTHWR DG# 14. Fabric duct - Exhaust air grille - Low temperature hot water return DP# - Dosing pot In-Line Ductwork Equipment E# - Exhaust air terminal / grille - Uninsulated ductwork - Low temperature hot water return (Single line) - Exhaust air disc valve EAF# - Exhaust air fan - Axial flow fan DR EXP# - Expansion tank - Condensate drain - Externally insulated ductwork FB# - Filter bank - Wall mounted transfer air grilles - Condensate drain (Single line) - Rectangular centrifugal or mixed flow fan FCU# - Fan coil unit MU - Internally insulated ductwork - Make-up water FD# - Fire damper - Wall mounted supply air grille - Mixed flow fan - Make-up water (Single line) HB# - Heater bank KEF# - Kitchen exhaust fan - Round ductwork - Wall mounted return air grille - Refrigerant piping, control and electrical L# - Louvre TL - Centrifugal fan wiring route MCV# - Motorised control valve - Taper (Top Level) - Outdoor air weather louvre 600L - Piping take-off "T" OAF# - Outdoor air fan - Cylindrical sound attenuator complete with pod OU# - Outdoor split system air conditioning unit BL - Exhaust air weather louvre - Piping stab-in "T" P# - Circulating pump 600L - Taper (Bottom Level) - Cylindrical sound attenuator with no pod R# - Return air terminal / grille - Door grille - Piping reducer ET/BW RAF# - Return air fan 600L - Taper (Equal taper / Both ways) S1 - Air terminal identification SA# - Sound attenuator - Rectangular sound attenuator - Piping elbow 100 - Air quantity in l/s SAF# - Supply air fan SL S# - Supply air terminal / diffuser 600L - Taper (Side Level) HVAC Electrical Components - Piping dropper - Filter bank in slide out frame SD# - Smoke damper MDB - Transfer air grille ET - Piping riser T# - Motor control centre / Distribution board General Abbreviations 600L - Taper rectangular to round (Equal taper) - Manual volume control damper - Piping riser VSD - Variable speed drive BMS - Building management system - Three phase isolator (WP = Weatherproof) - Blank flange COS - Check on site - Takeoff shoe - Manual opposed blade damper - Single phase isolator (WP = Weatherproof) CV - Control valve FB - Fullbore drain / Floor waste gulley - Actuator motor EC - Duct end cap - Motorised opposed blade damper - Make-up water point ID - Internal diameter (or dimension) - Radius bend without turning vanes EM - Energy meter MU MOS - Measure on site AH - After hours switch DP - Drain point with "P' trap NC - Normally closed - Back draught / Non return damper Sensors, Controllers and Switches Schematic Representation NO - Normally open - Radius bend with turning vanes T - Wall or ceiling mounted temperature sensor - Circulating pump (CHWP = Chilled water, CDWP = NTS - Not to scale Condenser water, LTHWP = Low temperature hot water) OBD - Opposed blade damper - Cross talk attenuator Ta - Averaging temperature sensor - Flexible coupling (FC) OE - Duct open end C - Wall mounted AC unit controller OD - Outside diameter (or dimension) - Round lobster back bend - Isolating & Regulating valve (IR) - Curtain type fusible link fire damper CC - Central controller SB - Seismic brace - Double regulating valve (DRV) SU - Duct sets up - Control Panel - Pressure Sensor CP P SD - Duct sets down - Mitre bend with turning vanes - Blade type fusible link fire damper - Isolating butterfly valve (IV) - Reed Switch - Solar Sensor TOS - Trim on site RS SS - Isolating ball valve (IV) UC - Undercut door by builder - Blade type motorised fire damper - After Hours Switch - Occupancy Sensor M AH OS - Motorised 2 port valve (MCV) VCD - Volume control damper M - Double bend PB - Push Button GD - Gas Detector - Motorised 3 port bypass valve (MCV) Taper Abbreviations BL - Bottom Level - Heater bank RH - Humidity Sensor S - Solenoid valve (SV) BW - Both Ways - Trouser piece C0 - Carbon Monoxide Sensor - Non-return / Check valve (NRV) ET - Equal Taper - Flexible canvas connection SL - Side Level CO₂ - Carbon Dioxide Sensor - Double check / Non-return valve (DCV) TL - Top Level.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us