HUDSON RIVER MUSEUM WEST WING BID ISSUE MARCH 16, 2020 ELECTRICAL SPECIFICATIONS DIVISION SECTION TITLE PAGES DIVISION 26 - ELECTRICAL 260519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 5 260526 GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS 6 260529 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 6 260533 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS 12 260544 SLEEVES AND SLEEVE SEALS FOR ELECTRICAL RACEWAYS AND CABLING 4 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS 13 262413 SWITCHBOARDS 12 262416 PANELBOARDS 10 262713 ELECTRICITY METERING 3 262726 WIRING DEVICES 7 262813 FUSES 3 262816 ENCLOSED SWITCHES AND CIRCUIT BREAKERS 6 263213.14 DIESEL ENGINE GENERATORS 18 263600 TRANSFER SWITCHES 9 264313 SURGE PROTECTION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS 5 265119 LED INTERIOR LIGHTING 8 265219 EMERGENCY AND EXIT LIGHTING 8 265619 EXTERIOR LIGHTING 9 DIVISION 28 - ELECTRONIC SAFETY AND SECURITY 280513 CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY 10 284621.11 ADDRESSABLE FIRE-ALARM SYSTEMS 18 END OF TABLE OF CONTENTS SECTION 260519 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Building wires and cables rated 600 V and less. 2. Connectors, splices, and terminations rated 600 V and less. 1.3 DEFINITIONS A. VFC: Variable frequency controller. 1.4 ACTION SUBMITTALS A. Product Data: For each type of product. 1.5 INFORMATIONAL SUBMITTALS A. Field quality-control reports. PART 2 - PRODUCTS 2.1 CONDUCTORS AND CABLES A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following: 1. Alpha Wire Company. 2. Belden Inc. 3. Cerro Wire LLC. 4. Encore Wire Corporation. 5. General Cable Technologies Corporation. 6. General Cable; General Cable Corporation. 7. Senator Wire & Cable Company. 8. Southwire Company. Hudson River Museum West Wing Low-Voltage Electrical Power Conductors And Cables - 1 March 16, 2020 B. Copper Conductors: Comply with NEMA WC 70/ICEA S-95-658. C. Conductor Insulation: Comply with NEMA WC 70/ICEA S-95-658 for Type THHN/THWN-2, Type XHHW-2 and Type SO. D. Multiconductor Cable: Comply with NEMA WC 70/ICEA S-95-658 for metal-clad cable, Type MC mineral-insulated, metal-sheathed cable, Type MI and Type SO with ground wire. E. VFC Cable: 1. Comply with UL 1277, UL 1685, and NFPA 70 for Type TC-ER cable. 2. Type TC-ER with oversized crosslinked polyethylene insulation, spiral-wrapped foil plus 85 percent coverage braided shields and insulated full-size ground wire, and sunlight- and oil-resistant outer PVC jacket. 2.2 CONNECTORS AND SPLICES A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following: 1. 3M. 2. AFC Cable Systems, Inc. 3. Gardner Bender. 4. Hubbell Power Systems, Inc. 5. Ideal Industries, Inc. 6. ILSCO. 7. NSi Industries LLC. 8. O-Z/Gedney; an EGS Electrical Group brand; an Emerson Industrial Automation business. 9. Tyco Electronics Corp. B. Description: Factory-fabricated connectors and splices of size, ampacity rating, material, type, and class for application and service indicated. 2.3 SYSTEM DESCRIPTION A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. B. Comply with NFPA 70. PART 3 - EXECUTION 3.1 CONDUCTOR MATERIAL APPLICATIONS A. Feeders: Copper. Solid for No. 10 AWG and smaller; stranded for No. 8 AWG and larger. Hudson River Museum West Wing Low-Voltage Electrical Power Conductors And Cables - 2 March 16, 2020 B. Branch Circuits: Copper. Solid for No. 10 AWG and smaller; stranded for No. 8 AWG and larger, except VFC cable, which shall be extra flexible stranded. 3.2 CONDUCTOR INSULATION AND MULTICONDUCTOR CABLE APPLICATIONS AND WIRING METHODS A. Service Entrance: Type XHHW-2, single conductors in raceway. B. Exposed Feeders: Type THHN/THWN-2, single conductors in raceway or Mineral-insulated, metal-sheathed cable, Type MI. C. Feeders Concealed in Ceilings, Walls, Partitions, and Crawlspaces: Type THHN/THWN-2, single conductors in raceway, Metal-clad cable, Type MC or Mineral-insulated, metal-sheathed cable, Type MI. D. Feeders Concealed in Concrete, below Slabs-on-Grade, and Underground: Type XHHW-2, single conductors in raceway. E. Exposed Branch Circuits, Including in Crawlspaces: Type THHN/THWN-2, single conductors in raceway. F. Branch Circuits Concealed in Ceilings, Walls, and Partitions: Type THHN/THWN-2, single conductors in raceway or Metal-clad cable, Type MC. G. Branch Circuits Concealed in Concrete, below Slabs-on-Grade, and Underground: Type THHN/THWN-2, single conductors in raceway or Type XHHW-2, single conductors in raceway. H. Cord Drops and Portable Appliance Connections: Type SO, hard service cord with stainless- steel, wire-mesh, strain relief device at terminations to suit application. I. VFC Output Circuits: Type TC-ER cable with braided shield. 3.3 INSTALLATION OF CONDUCTORS AND CABLES A. Conceal cables in finished walls, ceilings, and floors unless otherwise indicated. B. Complete raceway installation between conductor and cable termination points according to Section 260533 "Raceways and Boxes for Electrical Systems" prior to pulling conductors and cables. C. Use manufacturer-approved pulling compound or lubricant where necessary; compound used must not deteriorate conductor or insulation. Do not exceed manufacturer's recommended maximum pulling tensions and sidewall pressure values. D. Use pulling means, including fish tape, cable, rope, and basket-weave wire/cable grips, that will not damage cables or raceway. E. Install exposed cables parallel and perpendicular to surfaces of exposed structural members, and follow surface contours where possible. Hudson River Museum West Wing Low-Voltage Electrical Power Conductors And Cables - 3 March 16, 2020 F. Support cables according to Section 260529 "Hangers and Supports for Electrical Systems." 3.4 CONNECTIONS A. Tighten electrical connectors and terminals according to manufacturer's published torque- tightening values. If manufacturer's torque values are not indicated, use those specified in UL 486A-486B. B. Make splices, terminations, and taps that are compatible with conductor material and that possess equivalent or better mechanical strength and insulation ratings than unspliced conductors. C. Wiring at Outlets: Install conductor at each outlet, with at least 6 inches of slack. 3.5 IDENTIFICATION A. Identify and color-code conductors and cables according to Section 260553 "Identification for Electrical Systems." B. Identify each spare conductor at each end with identity number and location of other end of conductor, and identify as spare conductor. 3.6 SLEEVE AND SLEEVE-SEAL INSTALLATION FOR ELECTRICAL PENETRATIONS A. Install sleeves and sleeve seals at penetrations of exterior floor and wall assemblies. Comply with requirements in Section 260544 "Sleeves and Sleeve Seals for Electrical Raceways and Cabling." 3.7 FIRESTOPPING A. Apply firestopping to electrical penetrations of fire-rated floor and wall assemblies to restore original fire-resistance rating of assembly according to Section 078413 "Penetration Firestopping." 3.8 FIELD QUALITY CONTROL A. Perform the following tests and inspections: 1. After installing conductors and cables and before electrical circuitry has been energized, test service entrance and feeder conductors for compliance with requirements. 2. Perform each visual and mechanical inspection and electrical test stated in NETA Acceptance Testing Specification. Certify compliance with test parameters. 3. Infrared Scanning: After Substantial Completion, but not more than 60 days after Final Acceptance, perform an infrared scan of each splice in conductors No. 3 AWG and larger. Remove box and equipment covers so splices are accessible to portable scanner. Correct deficiencies determined during the scan. Hudson River Museum West Wing Low-Voltage Electrical Power Conductors And Cables - 4 March 16, 2020 a. Instrument: Use an infrared scanning device designed to measure temperature or to detect significant deviations from normal values. Provide calibration record for device. b. Record of Infrared Scanning: Prepare a certified report that identifies splices checked and that describes scanning results. Include notation of deficiencies detected, remedial action taken, and observations after remedial action. B. Test and Inspection Reports: Prepare a written report to record the following: 1. Procedures used. 2. Results that comply with requirements. 3. Results that do not comply with requirements and corrective action taken to achieve compliance with requirements. C. Cables will be considered defective if they do not pass tests and inspections. END OF SECTION 260519 Hudson River Museum West Wing Low-Voltage Electrical Power Conductors And Cables - 5 March 16, 2020 SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section includes grounding and bonding systems and equipment,
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages173 Page
-
File Size-