Optimizing Energy Efficiency and Improved Dehumidification Performance of Variable Capacity Air Conditioning Systems

Optimizing Energy Efficiency and Improved Dehumidification Performance of Variable Capacity Air Conditioning Systems

Optimizing Energy Efficiency and Improved Dehumidification Performance of Variable Capacity Air Conditioning Systems FSEC-PF-473-18 August 17, 2018 Presented at 2018 ACEEE Summer Study on Energy Efficiency in Buildings Author Chuck Withers, Florida Solar Energy Center® Copyright © 2018 American Council for an Energy Efficient Economy All rights reserved. No part of this work may be reproduced without consent of the Publisher: ACEEE 529 14th Street, N.W., Suite 600, Washington, D.C. 20045 phone: 202.507.4000 • fax: 202.429.2248 • e-mail: [email protected] • web: www.aceee.org www.fsec.ucf.edu Disclaimer The Florida Solar Energy Center/University of Central Florida nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the Florida Solar Energy Center/University of Central Florida or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the Florida Solar Energy Center/University of Central Florida or any agency thereof. Optimizing Energy Efficiency and Improved Dehumidification Performance of Variable Capacity Air Conditioning Systems Charles R. Withers Jr., Florida Solar Energy Center ABSTRACT High-performance homes promote high efficiency, but some of these homes, with very low cooling loads, may have greater challenges in delivering acceptable comfort. This paper discusses challenges and options regarding energy-efficient comfort control in homes with ducted and ductless variable capacity air conditioners based on recent research in occupied homes and house lab tests. Air conditioners cool and dehumidify. Well-designed homes can usually maintain acceptable temperature, but the likelihood of maintaining acceptable indoor humidity all the time is less certain. This is due to low sensible loads, variability in moisture removal effectiveness of air conditioning, and variability of moisture sources. As a result, some builders and high- performance home programs resort to using dehumidifiers. While dehumidifiers can improve relative humidity control, they present a different set of challenges and may cause significantly higher building energy use than owners expect. Variable capacity cooling energy savings typically around 20%-30% have been measured compared to fixed capacity systems in controlled house lab study. Research also found that better dehumidification is possible that limits overcooling and energy use. Recent testing of a new variable capacity system measured indoor humidity reduction of up to 15% RH points during low cooling load periods. Optimized variable capacity air conditioners may adequately control humidity at moderate levels without need for supplemental dehumidifiers. Such systems would require less annual space conditioning energy than sub-optimal variable capacity systems that require supplemental dehumidifiers in low sensible load homes. This paper will present research that shows how performance can be optimized, and discuss the importance of considering how cooling performance metrics impact cooling and dehumidification energy use. Introduction Based upon SEER ratings, variable capacity (VC) systems offer the highest cooling efficiencies and have good potential for maintaining thermal distribution due to long runtimes. Cooling loads vary hour to hour in homes. VC systems are designed to deliver cooling over a range of capacity which makes them a better match to actual load variability. A VC system varies indoor fan airflow as well as the refrigerant flow designed to operate at more than two distinct cooling capacities. These systems are available as central ducted, minisplit ductless or ducted, and multisplit ducted or ductless. VC systems have demonstrated good energy savings potential compared to central fixed capacity systems in lab and occupied home studies. An Oak Ridge National Lab study reported cooling savings of a ducted VC system of 41% in comfort mode and 44% in efficiency mode compared to a fixed capacity (FC) system (Munk et al. 2014). Another residential lab controlled study of 10 various test configurations measured cooling energy savings ranging from 19%-44% of ducted SEER 21/22 VC compared to a SEER 13 FC ducted system (Cummings, Withers, and Kono 2015). These ten tests were performed in a lab home without ASHRAE 62.2 ventilation ©2018 ACEEE Summer Study on Energy Efficiency in Buildings 1-1 with tight air ducts. The savings depended upon SEER, duct location, and system sizing. In another controlled lab study, with building leakage of 5 ACH50 and ASHRAE 62.2 mechanical ventilation, a ducted SEER 22 system had annual cooling savings of 22% and a supplemental SEER 21.5 ductless minisplit configuration had savings of 33% compared to a ducted central SEER 13 system (Withers 2016a). Testing with ASHRAE 62.2 ventilation was important due to the potentially high amount of moisture transported into homes during warm moist conditions that pose even greater challenges in controlling indoor humidity and increase energy use. A field study of ten Florida homes measured cooling energy savings from adding high SEER supplemental minisplits to homes with existing central ducted air conditioners. The concept of supplemental minisplit conditioning is a practice that allows a very high SEER minisplit to be added to an existing home with existing older central ducted air conditioner. The minisplit is placed in a central living area and operated at 2-3°F cooler than the central system thereby shifting initial cooling loads to the higher efficiency system. The central system is used with a fan cycle control to circulate air and provide additional cooling as needed. Some new homes are even being built with ducted and ductless minisplits. The ten Florida retrofits had median cooling savings of 33% with a range from 2%-46% energy reduction (Sutherland, Parker, and Martin 2016). Other work evaluating field installed ductless minisplits claim reasons for a large range in measured savings can be due, in part, to occupant behavior over operation or operation under conditions much different than the American National Standards Institute (ANSI) / Air-Conditioning, Heating, and Refrigeration Institute (AHRI) rating procedure (Walczyk and Larson 2016). This work found that some occupants may treat the system more like an appliance turning it on and off as desired instead of leaving it on at a specific setpoint which can diminish savings potential. While VC systems have shown good potential for energy savings, it is clear that they need better humidity control during warm moist weather in mechanically ventilated homes especially those with high internal moisture generation. There are various factors that could impact RH such as occupant variable loads, amount of mechanical ventilation, dehumidification performance of air conditioners, and occupant operation of equipment. Indoor RH can vary widely as the following studies illustrate. Periods of elevated indoor RH were observed in four new field study Habitat for Humanity homes solely cooled using mini and multisplit systems without supplemental dehumidification. The occupied homes exhibited indoor hourly average RH exceeding 60% an average of 61% of the time (range 11% to 86% frequency) (Martin et al. 2018). Another study of two homes in Austin, Texas found significant increases in humidity with 50% frequency or greater of hours with RH greater than 60% after central ducted systems were retrofitted with minisplit systems (Roth, Sehgal, and Akers 2013). Research in a house lab with ASHRAE 62.2 ventilation found a supplemental minisplit system test without supplemental dehumidifier resulted in average indoor RH exceeding 60% between 4%-15% of the test hours depending upon the room (Withers 2016b). High-performance low cooling load homes can be challenged to maintain indoor RH below at least 60% many hours of the year. High performance homes can have improved thermal distribution, but may have decreased comfort and higher potential for moisture issues due to inadequate RH control. Air conditioning alone is challenged due to lower runtimes not just during cooler days, but also during overnight periods of hot weather. A supplemental dehumidifier is then needed where tighter control of indoor RH is required. Supplemental dehumidification works generally well to ensure RH control, however it adds another appliance that must be maintained and can use a substantial amount of energy. On 1-2 ©2018 ACEEE Summer Study on Energy Efficiency in Buildings the higher end of use, dehumidifier energy in mechanically vented homes during hot-humid weather can be about 10 kWh/day representing about 49% of the cooling and dehumidifier energy use (Ruud, Lstiburek, and Ueno 2005). Accounting for the energy required for supplemental dehumidification is very important and may represent a significant amount of space conditioning energy. High performance homes being rated without accounting for dehumidifier energy in cases when it is needed may explain higher than expected energy use. One simulation indicated an energy increase of 2MBtu/year associated with a Building

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    16 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us