OPERATORS MANUAL FOR Mi-T-M® CORONA DISCHARGE OZONE GENERATORS CAUTION RISK OF INJURY! READ MANUAL BEFORE OPERATING! This manual is an important part of the Corona Discharge Ozone Generator and must remain with the unit when you sell it! ©Copyright 2005, Mi-T-M Corporation® Form #37-0842-09405 Mi-T-M® Corona Discharge Ozone Generator Operator's Manual Table of Contents INTRODUCTION ............................................................................................................................................................. 3 SPECIFICATIONS ........................................................................................................................................................... 4 IMPortANT SAFETY WARNINGS ............................................................................................................................. 5-6 RISK OF ELECTRIC SHOCK OR ELECTROCUTION ............................................................................................. 5 RISK OF EXPLOSION OR FIRE .............................................................................................................................. 6 RISK OF ASPHYXIATION......................................................................................................................................... 6 NOTES ............................................................................................................................................................................ 7 INSTALLATION ............................................................................................................................................................ 8-9 ATTIRE ..................................................................................................................................................................... 8 LOCATION ................................................................................................................................................................ 8 MOUNTING ........................................................................................................................................................... 8-9 ELECTRICAL ............................................................................................................................................................ 9 OPERATION .................................................................................................................................................................. 0 START-UP ............................................................................................................................................................... 0 OPERATION ........................................................................................................................................................... 0 SHUT-DOWN .......................................................................................................................................................... 0 MAINTENANCE .............................................................................................................................................................11 SYSTEM ELECTRO-MECHANICAL OVERVIEW ...................................................................................................11 SYSTEM MAINTENANCE .......................................................................................................................................11 SERVICE ....................................................................................................................................................................... 2 GENERATOR SERVICING ..................................................................................................................................... 2 TROUBLESHOOTING .................................................................................................................................................. 3 PARTS LIST ............................................................................................................................................................. 4-8 STATEMENT OF WARRANTY ...................................................................................................................................... 9 Mi-T-M® Corona Discharge Ozone Generator Operator's Manual INTRODUCTION Congratulations on the purchase of your new Mi-T-M Corona Discharge Ozone Generators! You can be assured your Mi-T-M Corona Discharge Ozone Generators was constructed and designed with quality and performance in mind. Each component has been rigorously tested to ensure the highest level of acceptance. This operator's manual was compiled for your benefit. By reading and following the simple safety, installation, operation, maintenance and troubleshooting steps described in this manual, you will receive years of trouble free operation from your new Mi-T-M Corona Discharge Ozone Generators. The contents of this manual are based on the latest product information available at the time of publication. Mi-T-M reserves the right to make changes in price, color, materials, equipment, specifications or models at any time without notice. ! IMPORTANT ! These paragraphs are surrounded by a "SAFETY ALERT BOX". This box is used to designate and emphasize Safety Warnings that must be followed when operating this Corona Discharge Ozone Generator. Accompanying the Safety Warnings are "signal words" which designate the degree or level of hazard seriousness. The "signal words" used in this manual are as follows: DANGER: Indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. WARNING: Indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided MAY result in minor or moderate injury. The symbols set to the left of this paragraph are "Safety Alert Symbols". These symbols are used to call attention to items or procedures that could be dangerous to you or other persons using this equipment. ALWAYS PROVIDE A COPY OF THIS MANUAL TO ANYONE USING THIS EQUIPMENT. READ ALL INSTRUCTIONS BEFORE OPERATING THIS CORONA DISCHARGE OZONE GENERATOR AND ESPECIALLY POINT OUT THE "SAFETY WARNINGS" TO PREVENT THE POSSIBILITY OF PERSONAL INJURY TO THE OPERATOR. Immediately write in the serial number of your generator in the space provided below. SERIAL NUMBER_________________________________ Inspect for signs of obvious or concealed freight damage. If damage does exist, file a claim with the transportation company immediately. Be sure that all damaged parts are replaced and that the mechanical and electrical problems are corrected prior to operation of the unit. If you require service, contact Mi-T-M Customer Service. CUSTOMER SERVICE CALL OUR TOLL-FREE NUMBER for the Sales or Service Center nearest you! 800-553-9053 Please have the following information available for all service calls: . Model Number 2. Serial Number 3. Date and Place of Purchase Mi-T-M® Corona Discharge Ozone Generator Operator's Manual 3 SPECIFICATIONS MODEL 32-0860 32-0861 32-0862 32-0863 32-0865 32-0866 Ozone Output: Ozone Output Medium Flow Medium Flow High Flow High Flow Low Flow Low Flow Flow Rate 5 scfh Power Requirements: Domestic 20V, 60Hz, 240V, 60Hz, 20V, 60Hz, 240V, 60Hz, 20V, 60Hz, 240V, 60Hz, 0, 0.2 Amp 0, 0.06 Amp 0, 0.24 Amp 0, 0.2 Amp 0, 0.2 Amp 0, 0.06 Amp International - 240V, 50Hz, - 240V, 50Hz, - 240V, 50Hz, 0, 0.06 Amp 0, 0.2 Amp 0, 0.06 Amp Shipping Weight: Approximate (lbs / kg) 5.5 / 2.5 5.5 / 2.5 0.5 / 4.8 0.5 / 4.8 5.5 / 2.5 5.5 / 2.5 Location Requirements: Mounting Wall mount in a clean, protected area. Ambient Temp. 30° F - 20° F (0° C - 50° C) The Mi-T-M Corona Discharge Series Ozone Generators described in this manual are designed to provide the benefits of ozonated water in an environmentally safe and effective manner. The high quality, specially engineered components ensure efficient ozone output and reliable performance. As a result of proper use of the Mi-T-M Corona Discharge Ozone Generators, unpleasant effects of traditional chemical use are virtually eliminated. The Mi-T-M Corona Discharge Ozone Generators are safe and harmless to your equipment when installed properly. Mi-T-M® Corona Discharge Ozone Generator Operator's Manual IMPORTANT SAFETY WARNINGS WARNING: When using this product, basic precautions should always be observed, including the following: READ ALL SAFETY WARNINGS BEFORE USING THE CORONA DISCHARGE OZONE GENERATOR HAZARD POTENTIAL CONSEQUENCE PREVENTION RISK OF ELECTRIC SHOCK Serious injury or death could Read this manual completely before attempting OR ELECTROCUTION occur if the Corona Discharge installation. Ozone Generator is not properly All permanent electrical connections should be grounded. Your Corona Discharge made by a qualified electrician. Ozone Generator is powered by For cord and plug-connected units, connect to a electricity and may cause electric grounded, grounding type receptacle only. If the shock or electrocution if not installed Mi-T-M Corona Discharge Ozone Generator is properly. connected to an independent electrical supply, then a G.F.C.I. must be installed between the generator and the electrical supply. Do not bury cord. To reduce the risk of electrical shock, replace damaged cord immediately. A pressure wire connector is provided on the outside of the unit to permit connection to a minimum No. 8 AWG (8.4 mm2) solid
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages20 Page
-
File Size-