Development of Un-Targeted Screening Method for Detection of Synthetic PDE-5 Inhibitors and Analogues Adulterated in Health Supplements on LCMS-IT-TOF

Development of Un-Targeted Screening Method for Detection of Synthetic PDE-5 Inhibitors and Analogues Adulterated in Health Supplements on LCMS-IT-TOF

PO-CON1538E Development of Un-targeted Screening Method for Detection of Synthetic PDE-5 Inhibitors and Analogues Adulterated in Health Supplements on LCMS-IT-TOF ASMS 2015 TP102 Jie Xing1, Dinash Aravind2, Zhe Sun1, Ang May Yen3 and Zhaoqi Zhan1 1 Shimadzu (Asia Pacic) Pte Ltd, 79 Science Park Drive #02-01/08, Singapore 118264, 2 National Pharmaceutical Control Bureau, Jalan Universiti, 46200 PetalingJaya, Selangor, Malaysia, 3 Shimadzu Malaysia SdnBhd, Kota Damansara, 47810 PetalingJaya, Selangor, Malaysia Development of Un-targeted Screening Method for Detection of Synthetic PDE-5 Inhibitors and Analogues Adulterated in Health Supplements on LCMS-IT-TOF Introduction Sildenal and other synthetic phosphodiesterase type 5 LC/MS/MS [1-3] are used for detection of targeted PDE-5 enzyme (PDE-5) inhibitors are used for treatment of erectile inhibitors, but it is challenging to detect unknown dysfunction (ED) in men. Sildenal, tadalal, vardenal, adulterants in actual samples. We present here a novel avanal and udenal are the approved PDE-5 drugs in un-targeted screening method using LCMS-IT-TOF and a different countries [1]. However, adulteration of PDE-5 MetID program with database function. A multi-event inhibitors and their analogues are found in dietary method was used to acquire HR-TICs with enhanced supplements and health products in recent years [1-3]. The sensitivity. An un-targeted screening approach was adulteration is illegal and dangerous for consumers established using a concerned compound database of because none of the analogues is approved ofcially for thirty-two PDE-5 inhibitors and their analogues and applied medical use. Analytical methods based on HPLC and to ve health supplements obtained from local market. Experimental Thirty-two synthetic PDE-5 inhibitors and analogues were employed in this study to develop un-targeted screening obtained from TLC PharmaChem (Canada). These method based on high resolution (HR) and accurate mass compounds were dissolved in MeOH at 100ppm or 10ppm measurement. A Shim-pack C18 column (150x2.0mm, as stocks and were used as standards. Five health 5um) was used and a gradient elution program was supplements in capsules obtained from local markets were optimized to achieve separation of these thirty-two selected as matrixes to prepare spiked samples for method compounds. The mobile phases used were milli-Q water performance evaluation. These samples are named as M, (A) and acetonitrile (B), both with 0.1% formic acid. The C, PP, TA and RK for convenience. Sample pre-treatment gradient program adopted was B (%): 10% (0.01min) → includes extraction of the samples at a ratio of 1.0 gram of 75% (18-20min) → 10% (20.01-25min). A multievent TIC powders in 10 mL of pure MeOH. The mixture was data acquisition method was used with each event sonicated for 20 minutes, followed by ltration with 0.2um covering 50Da only to improve the detection sensitivity. PTFE lter before analysis. A high resolution LCMS-IT-TOF Standard ESI conditions in positive mode were applied. The coupled with a UFLC (Shimadzu Corporation, Japan) was injection volume used was 5uL unless indicated separately. Results and Discussion Comparison of multi-event method with single-event method In an un-targeted screening analysis using LC-TOF, total ion in each event (50Da). The full range of m/z 200-600 was chromatograms (TICs) of fullspectrum are acquired to cover covered by eight events. To evaluate the sensitivity of this all concerned masses. This requires the TOF-MS capable of method, a comparison study of the multi-event method acquiring data with high accuracy, high sensitivity and and the single event method was performed with mixture excellent selectivity to reduce the chance of false negative standards of 0.1ppm and 0.5ppm. The results (Figure 1) detection of concerned compounds that may be present in revealed that the peak areas of multi-event TIC increased the samples studied. However, a TIC usually consists of a twice on average than that acquired with a single event high background baseline and interference peaks, which method (m/z 200-600) in detection of the 32 PDE-5 may cause small peaks submerged under the baseline and inhibitors and analogues (Table 1). The extract ion become not detectable. In this work, a multi-event TIC chromatogram (EIC) method using the multi-event was method was adopted to acquire data with a narrow range compared with that of the single event method (Figure 2). 2 Development of Un-targeted Screening Method for Detection of Synthetic PDE-5 Inhibitors and Analogues Adulterated in Health Supplements on LCMS-IT-TOF Table 1: Comparison of multi-event method and single-event method in detection of 32 PDE-5 inhibitor and analogues (0.1ppm) A (Multi-event) name Formula CAS [M+H]+ RT (min) /A (Single-event) YOHIMBINE C21H26N2O3 146-48-5 355.2016 4.58 1.2 ACETYLVARDENAFIL C25H34N6O3 1261351-28-3 467.2765 5.01 1.9 CARBODENAFIL C24H32N6O3 944241-52-5 453.2609 5.80 1.9 N-DESMETHYL ACETILDENAFIL C23H30N6O3 n.a. 439.2452 5.84 2.8 HYDROXYHOMOSILDENAFIL C23H32N6O5S 139755-85-4 505.2228 5.86 5.7 VARDENAFIL C23H32N6O4S 224785-90-4 489.2279 5.95 3.3 HYDROXYACETILDENAFIL C25H34N6O4 147676-56-0 483.2714 6.01 2.9 NORACETILDENAFIL C24H32N6O3 949091-38-7 453.2665 6.13 2 ACETILDENAFIL C25H34N6O3 831217-01-7 467.2765 6.29 1.6 PIPERIACETILDENAFIL C24H31N5O3 147676-50-4 438.2456 6.69 1.6 AVANAFIL C23H26ClN7O3 330784-47-9 484.1858 6.94 1.2 HYDROXYVARDENAFIL C23H32N6O5S 224785-98-2 505.2227 7.02 2.6 SILDENAFIL C22H30N6O4S 171599-83-0 475.2127 7.07 2.8 HOMOSILDENAFIL C23H32N6O4S 642928-07-2 489.2278 7.19 2.2 DIMETHYLSILDENAFIL C23H32N6O4S 1416130-63-6 489.2277 7.42 2.3 UDENAFIL C25H36N6O4S 268203-93-6 517.2592 7.71 2.7 N-DESETHYL VARDENAFIL C21H28N6O4S 448184-46-1 461.2041 9.12 1.4 BENZYLSILDENAFIL C28H34N6O4S n.a. 551.2435 9.12 2.8 HYDROXYTHIOHOMOSILDENAFIL C23H32N6O4S2 479073-82-0 521.1999 9.32 3.3 THIOSILDENAFIL C22H30N6O3S2 479073-79-5 491.1894 9.41 2.7 THIOHOMOSILDENAFIL C23H32N6O3S2 479073-80-8 505.205 9.56 3.1 THIODIMETHYLSILDENAFIL C23H32N6O3S2 856190-47-1 505.2009 9.75 2.9 AMINOTADALAFIL C21H18N4O4 385769-84-6 391.1401 9.76 0.9 NORTADALAFIL C21H17N3O4 171596-36-4 376.1292 9.96 0.5 VARDENAFIL intermediate C17H20N4O2 n.a. 313.1659 9.97 1.2 TADALAFIL C22H19N3O4 171596-29-5 390.1448 10.81 0.8 PSEUDOVARDENAFIL C22H29N5O4S 224788-34-5 460.2013 12.51 2 GENDENAFIL C19H22N4O3 147676-66-2 355.1765 12.99 1.8 N-BUTYL TADALAFIL C25H25N3O4 171596-31-9 432.2034 13.99 0.4 CHLOROPRETADALAFIL C22H19ClN2O5 171489-59-1 427.1055 14.38 0.8 NORNEOSILDENAFIL C22H29N5O4S 371959-09-0 460.2014 15.98 2.4 N-OCTYL NORTADALAFIL C29H33N3O4 1173706-35-8 488.2518 18.52 0.5 3 Development of Un-targeted Screening Method for Detection of Synthetic PDE-5 Inhibitors and Analogues Adulterated in Health Supplements on LCMS-IT-TOF (a) Multi-event (b) Multi-event E1: 200-250 E1: 200-250 E2: 250-300 E2: 250-300 E3: 300-350 E3: 300-350 E4: 350-400 E4: 350-400 E5: 400-450 E5: 400-450 E6: 450-500 E6: 450-500 E7: 500-550 E7: 500-550 E8: 550-600 E8: 550-600 (b) Single-event (a) Single-event E1: 200-600 E1: 200-600 Fig 1: Comparison of TICs of 32 mixed standard of PDE-5 inhibitor Fig 2: HR-EICs of mixed standard of thirty-two PDE-5 inhibitor drugs and analogues of 0.1ppm acquired by multievent drugs and analogues of 0.1ppm acquired by multi- TIC method (a) and single event TIC method (b). event method (a) and the single event method (b). Un-targeted screening method on LCMS-IT-TOF Un-targeted screening workow: The workow based mass spectrometer. Figure 4a shows the complex on LCMS-IT-TOF and MetID Solution program is shown in chromatogram (by single-event method) of MeOH extract Figure 3. First, a concerned compound database with of sample M, which was conrmed to be free of the their accurate masses was created in the MetID Solution thirty-two compounds. Figure 4c is the chromatograms of program. The thirty-two PED-5 inhibitors and analogues 0.5ppm mixed standards spiked in the same matrix (M). studied are registered into the database, which includes This spiked sample was also analysed by multi-event the information of names, formula and accurate masse, method (Figure 4d) and the raw data was subjected to but without retention times. A method for data analysis un-targeted screening analysis. Data analysis of and database search is set up, which includes appropriate un-targeted screening is a process of peak detection, peak detection and peak picking parameters, and peak picking and database search to generate a found database search criteria like mass error allowed (e.g., +/- lihealth supplement samples as st of candidates. Table 3 5ppm). After a raw data le acquired with Multi-event shows the found list in sample M spiked with 0.1ppm of method is submittted to the MetID solution program, thirty-two PDE-5 inhibitors and analogues. It is worth to data analysis and database search is performed without note that this data analysis process may result in a long restriction of RTs and other specic parameters related to list of candidates if the peak detection (integration particular compounds. The above work-ow was applied parameters), peak picking and database settings (mass to the MeOH extracts of the ve health products & their error margin etc) are in a more sensitive range.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    8 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us