A Semi-Chronic Motorized Microdrive and Control Algorithm for Autonomously Isolating and Maintaining Optimal Extracellular Action Potentials

A Semi-Chronic Motorized Microdrive and Control Algorithm for Autonomously Isolating and Maintaining Optimal Extracellular Action Potentials

Articles in PresS. J Neurophysiol (June 30, 2004). 10.1152/jn.00369.2004 Cham et al. (JN-00369-2004.R1) A semi-chronic motorized microdrive and control algorithm for autonomously isolating and maintaining optimal extracellular action potentials Jorge G. Cham,1 Edward A. Branchaud,1 Zoran Nenadic,1 Bradley Greger,2 Richard A. Andersen,2 and Joel W. Burdick1 1 Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA 91125 2 Division of Biology, California Institute of Technology, Pasadena, CA 91125 Abstract A system was developed that can autonomously position recording electrodes to isolate and maintain optimal quality extracel- lular signals. The system consists of a novel motorized miniature recording microdrive and a control algorithm. The micro- drive was designed for chronic operation and can independently position four glass-coated Pt-Ir electrodes with micron precision over a 5mm range using small (3mm diameter) piezoelectric linear actuators. The autonomous positioning algorithm is designed to detect, align and cluster action potentials, and then command the microdrive to optimize and maintain the neural signal. This system is shown to be capable of autonomous operation in monkey cortical tissue. 1. Introduction al. 1999, Rousche and Normann 1998). The signal yield of the implant array, i.e. the percentage of the array's A fundamental challenge in experimental neurophysiol- electrodes that record active cells, depends upon the luck ogy and the development of brain-machine interfaces is of the initial surgical placement. Moreover, small tissue to record high quality action potentials from neuronal migrations, inflammation, cell expiration or reactive glio- populations. Since the development of the recording elec- sis can all cause subsequent loss of signal, thereby reduc- trode (Adrian 1926, Hubel 1957, Green 1958), two gen- ing or disabling the function of the recording array over eral approaches have emerged: acute and chronic time. recording methods. In acute recordings, individual elec- trodes are advanced into tissue at the beginning of each Chronic microdrives have been reported by several recording session through a cranial chamber, commonly investigators. Variations of a common design in which by devices termed microdrives. The electrodes are manual turning of lead screws advances individual or advanced carefully until high quality neural activity is small bundles of electrodes include Wall et al. (1967), found. During the course of an experiment, readjustment Kubie (1984), Vos et al. (1999), Venkatachalam et al. of the electrode's position is often required to re-optimize (1999), Kralik et al. (2001), Tolias, et al. (2002) and and maintain signal quality. While this method allows the Keating et al. (2002). Hoffman and McNaughton (2002) experimentalist flexibility in exploring different cell and deCharms et al. (1999) presented designs for chronic types, the process of signal optimization consumes a sig- implants with large arrays of movable electrodes (49 and nificant amount of time, even from an experienced opera- 144 respectively), in which a conventional microdrive is tor. This is especially true for manual microdrives. manually used to push or pull each electrode. Again, the Although motorized microdrives are commercially avail- amount of manual operation required to reposition each able (for example, Thomas Recording GmbH, Germany; electrode in these devices can be impractical if not intrac- FHC Inc., USA; Narishige Inc., Japan), the process of table. Moreover, it is difficult to ensure with such probes advancing the electrodes is still guided by human intu- that specific neurons are tracked over time, as neuronal ition, and it can be tedious or even impractical as the signals may be lost between adjustments. However, number of electrodes increases (Baker et al. 1999). arrays with this many (or more) electrodes are likely to be needed for future working neuroprostheses. In this case, In chronic recordings, stationary multi-electrode assem- it is clearly not practical to require periodic manual blies, which are typically bundles or arrays of thin wires adjustments of microdrives implanted on paralyzed or silicon probes, are surgically implanted in the region patients. of interest (for example, Porada, et al. 2000, Williams et Final Accepted Version - Page 1 of 14 Copyright © 2004 by the American Physiological Society. Cham et al. (JN-00369-2004.R1) Fee and Leonardo (2001) described a motorized Motor assembly 10mm chronic microdrive with two movable electrodes that is and electrode suitable for freely behaving small animals such as the carrier tubes zebra finch. This device, which uses two miniature elec- Vertical tric motors, was still operated under human control. Fee Positioner Knob and Leonardo reported that the ability to easily adjust the Chamber electrodes led to significant improvements in experimen- Adapter tal productivity. This insight is promising for the activi- Positioner ties of this paper that go beyond manual electrode adjustment to automated adjustment of multiple elec- Guide 10mm tube trodes. Related work includes the stabilization of elec- Standard trodes for intracellular recordings over a period of a few a) b) Chamber minutes by Fee (2000), and the control architecture for a commercial acute multielectrode microdrive by Baker et c) Position Brass al. (1999), which autonomously advances electrodes until Sensor Bushings target cells are detected, at which point human operators Motor Assembly Piezoelectric optimize the signal. To date no miniature microdrive has Actuators Vertical been reported that can seek out, optimize and maintain Positioner Brass extracellular action potentials in a fully autonomous fash- Knob Manifold ion. Positioner Electrodes This paper describes a motorized microdrive that can Chamber Standard autonomously position four independent electrodes and Adapter Chamber that is suitable for semi-chronic operation in monkeys. Fluid Acrylic By the term semi-chronic, we mean that it can be used Delivery Cover within a recording chamber for a period of a few weeks. Channels Motor Skull We describe a novel microdrive design, which uses min- Assemb. Cap iature piezoelectric linear actuators. The underlying the- Dura ory for the autonomous algorithm used to control the Guide Brain tube device is only summarized here, and is described in more Tissue detail in Nenadic and Burdick (2004). Finally, we present 10mm experimental results including autonomous isolations of cells in monkey cortex. Motor The autonomous probe positioning algorithm can be Assembly Guide implemented on a wide variety of devices. Additionally, tube the mechanical microdrive design can also be used as a Positioner Standard conventional human-guided microdrive, and has the Chamber Chamber advantage of extremely small size. While the microdrive Adapter and control algorithm presented here are independent of d) each other, the system described in this paper serves as a test-bed for developing future "smart" neural recording implants that are fully autonomous. The full realization Figure 1. Design of the prototype microdrive. a) Rendered of the dream of a miniaturized chronically implantable model of the design; b) standard cranial chamber used in labo- autonomous electrode array will await further advances ratory; c) cross-section of the device inside of chamber, illus- in micro-machine technology. In the short term, by trating relative position to skull and brain tissue; d) front view reducing the amount of time required for an operator to of the device: rotation of the motor assembly and positioner allows X-Y positioning of the guide tube. isolate a cell, by allowing many cells to be isolated in parallel, and by maintaining high signal quality, autono- mously operated microdrives can greatly increase the efficiency with which neurophysiological studies are conducted. Final Accepted Version - Page 2 of 14 Cham et al. (JN-00369-2004.R1) 2. Methods Piezoelectric Carrier Guidetube Actuators Tubes Front View 2.1 Motorized microdrive design The basic design of our prototype is shown in Figure 1a. The prototype is designed to fit inside a standard lab- oratory cranial chamber, used for acute experiments in b) non-human primates, to allow semi-chronic operation. A 0.5mm semi-chronic design has the advantage that the device can Polyimide Channels be repositioned over a different region with minimal Guidetube and cap effort and without need for additional surgeries. The Back View chamber, shown in Figure 1b, is a hollow plastic cylinder that is placed over a craniectomy and embedded in acrylic. The chamber can be sealed airtight using a cap, Brass 5mm as shown in the figure. Manifold c) As illustrated in Figure 1c, the device consists of a core a) Electrodes motor assembly that fits inside a gross vertical and hori- are secured zontal positioner. The positioner in turn is fitted inside to the brass the chamber through a chamber adapter. The motor bushings by assembly consists of four piezoelectric actuators, a cylin- set screws. drical brass manifold and a cylindrical cap, as shown in the figure. A short guide tube emerges from the cap, with Bent four inner channels spaced 500 microns apart through electrodes which the electrodes are lowered. This guide tube is off- are back- loaded into center relative to the motor assembly, while the motor the motor assembly and positioner are arranged as non-concentric assembly... cylinders. Rotation of both the motor assembly and the positioner

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    14 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us