Certificate of Analysis

Certificate of Analysis

Kaycha Labs Glee 7,000 MG Broad Spectrum Tincture N/A Matrix: Derivative 4131 SW 47th AVENUE SUITE 1408 Sample:DA00416007-007 Harvest/Lot ID: N/A Certificate Seed to Sale #N/A Batch Date :N/A Batch#: GBS700004142020 Sample Size Received: 4 ml of Analysis Retail Product Size: 30 ml Ordered : 04/14/20 Sampled : 04/14/20 Completed: 04/22/20 Expires: 04/22/21 Sampling Method: SOP Client Method Apr 22, 2020 | Glee PASSED 10555 W Donges Court Milwaukee Wisconsin, United States 53224 Page 1 of 1 PRODUCT IMAGE SAFETY RESULTS MISC. Pesticides Heavy Metals Microbials Mycotoxins Residuals Filth Water Activity Moisture Terpenes NOT TESTED NOT TESTED NOT TESTED NOT TESTED Solvents NOT TESTED NOT TESTED NOT TESTED NOT TESTED NOT TESTED CANNABINOID RESULTS Total THC Total CBD Total Cannabinoids 0.000% 24.898% 26.076% CBC CBGA CBG THCV D8-THC CBDV CBN CBDA CBD D9-THC THCA 24.898 ND ND 1.178% ND ND ND ND ND % ND ND 11.780 248.980 ND ND mg/g ND ND ND ND ND mg/g ND ND LOD 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.0001 0.0001 0.001 % % % % % % % % % % % Cannabinoid Profile Test Analyzed by Weight Extraction date : Extracted By : 450 0.1065g NA NA Analysis Method -SOP.T.40.020, SOP.T.30.050 Reviewed On - 04/22/20 15:36:44 Analytical Batch -DA011837POT Instrument Used : DA-LC-003 Batch Date : 04/21/20 11:36:57 Reagent Dilution Consums. ID 042120.R21 400 042120.R20 Full spectrum cannabinoid analysis utilizing High Performance Liquid Chromatography with UV detection (HPLC-UV). (Method: SOP.T.30.050 for sample prep and Shimadzu High Sensitivity Method SOP.T.40.020 for analysis. LOQ for all cannabinoids is 1 mg/L). This report shall not be reproduced, unless in its entirety, without written approval from Kaycha Labs. This report is an Kaycha Labs certification. The results relate only to the material or product analyzed. Test results are confidential unless explicitly waived otherwise. Void after 1 year from test end date. Cannabinoid content of batch material may vary depending on sampling error. IC=In-control QC parameter, NC=Non-controlled QC parameter, Jorge Segredo ND=Not Detected, NA=Not Analyzed, ppm=Parts Per Million, ppb=Parts Per Billion. Limit of Detection (LoD) and Lab Director 04/22/2020 Limit Of Quantitation (LoQ) are terms used to describe the smallest concentration that can be reliably measured by an analytical procedure. RPD=Reproducibility of two measurements. Action Levels are State determined thresholds State License # n/a for human safety for consumption and/or inhalation. The result >99% are variable based on uncertainty of ISO Accreditation # 97164 ___________________ ___________________ measurement (UM) for the analyte. The UM error is available from the lab upon request.The "Decision Rule" for the Signature Signed On pass/fail does not include the UM. The limits are based on F.S. Rule 64-4.310..

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us