Marine Fire Detection Systems

Marine Fire Detection Systems

Marine Fire Detection Systems Commercial Military Passenger Yachts On Board, On Guard Fire Suppression . Fire Detection . Gas Detection www.fireboy-xintex.co.uk www.fireboy-xintex.com [email protected] +44 (0)845 389 9462 Fireboy-Xintex Fireboy-Xintex have been supplying the Marine Industry with Clean Agent Fire Sup- pression systems for more than 35 years, benefitting from many world class builders within our portfolio, this success is due an excellent design,engineering and customer service focus. In recent years our move into Superyacht and Commercial Marine projects and the introduction of MED Approved Fire Suppression and Detection equipment has enabled the provision of a variety of reliable, trouble-free fire detection, fire suppression and gas detection systems for the marine & offshore industry. Fireboy-Xintex systems are designed and supplied appropriate to the class of vessel/ project under the following guidelines, ISO 9094, RCD, CE, MCA and all IACS mem- bers regulations. Specialising in total flooding clean agent extinguishing systems utilising either 3M™ Novec™ 1230 fire protection fluid or HFC-227ea fire extinguishant, both of which are approved by all IACS members. From your required design concepts Fireboy-Xintex can produce all the required documentation for Class Society Approval using the latest CAD software in both 2D and 3D. Fireboy-Xintex were the first company to pioneer the Marine ‘Electrical Release Panel’ for clean agent systems fully conforming to Msc.Circ. 848/1267 and has proved very popular with Superyacht and ship builders alike. The Release panel is available for single or multiple cylinder systems. For further information on the complete range of Fireboy-Xintex Clean agent Fire Suppression Systems please visit either of our website’s depending on your location. www.fireboy-xintex.co.uk www.fireboy-xintex.com page 2 www.fireboy-xintex.co.uk www.fireboy-xintex.com [email protected] +44 (0)845 389 9462 Contents FR & FRA Series 1 & 2 Zone Conventional FACP (Non-Approved) page 4 FR-8000 8 Zone Conventional FACP (Non-Approved) page 5 General Alarm Tone Generator Page 5 12 Zone Modular Conventional FACP page 6 Gas Detection System page 7 ASM 2 Loop Analogue Addressable FACP (Marine Approved) page 8 ASM Repeater Panels page 9 Mariner Pacific 4 Loop Analogue Addressable FACP Page 10 Mariner ‘Ocean’ Conventional 4-12 Zone FACP (Marine Approved) Page 11 Conventional MED Approved Detection Devices Page 12 Conventional MED Approved Sounders & Beacons Page 13 Addressable MED Approved Detection devices Page 14/15 Loop Powered MED Approved Sounders & Beacons Page 16 DIN-Rail Components & Accessories Page 17 Blank Page Page 18 Blank Page Page 19 page 3 www.fireboy-xintex.co.uk www.fireboy-xintex.com [email protected] +44 (0)845 389 9462 PLEASURE CRAFT & Marine 1 & 2 Zone Conventional Detection SMALL COMMERCIAL Systems (for <24m vessels not requiring marine approvals) Specifically designed to meet the requirements for small boat fire detection, thisange r is ideally suited for both new build and aftermarket retro-fit. Simply mounted through a 55mm hole and with a membrane front face giving excellent protection from the elements the units can be powered by either 12V or 24V. Coupled to ‘Orbis’ Marine Approved Detection devices from Apollo, users can be confident that this low cost option will give many years of trouble free protection. Measuring just 66mm x 66mm the detection panels can be mounted in the most convenient space avail- able and with four different options available are suitable for many Pleasure Craft (ISO 9094, RCD) and Small Commercial Vessels (MGN 280) under 24M Specifications Minimum (alarm current) 10mA Operating voltage 9 - 30vdc Maximum current per zone 320mA (including EOL) Siren/Buzzer output 12vdc @ 800mA Extinguisher Output Unit Supply vdc @ 500mA Charged Input 10 to 30vdc Supply voltage @ 12vdc Maximum sensors = 14 per zone (2K2 EOL) Supply voltage @ 24vdc Maximum sensors = 8 per zone (5K6 EOL) Dimensions: Face 66mm x 66mm x 5mm Depth Required 90mm Hole Size 55mm FR-1000 Single Zone 12/24V Supply Max 14 Detection Devices 12V Max 8 Detection Devices 24V FR-2000 Dual Zone Labelled ‘Engine Room’ & ‘Accom’ page 1 12/24V Supply Max 14 Detection Devices per Zone 12V Max 8 Detection Devices per Zone 24V EARTH EARTH EARTH FRA-1000 Single Zone 12/24V Supply Max 14 Detection Devices 12V Devices connected as above Max 8 Detection Devices 24V Electrical Extinguisher Activation Electrical Activation Pressure monitor FRA-2000 Dual Zone 12/24V Supply Labelled ‘Engine Room’ & ‘Accom’ Max 14 Detection Devices 12V Max 8 Detection Devices 24V Press Both Buttons For 5 Seconds Electrical Extinguisher Activation page 4 www.fireboy-xintex.co.uk www.fireboy-xintex.com PLEASURE CRAFT & [email protected] Marine 4 & 8Zone +44 (0)845 389 9462 SMALL COMMERCIAL Conventional Detection (for <24m vessels not requiring marine approvals) Systems (for <24m vessels not requiring marine approvals) For those applications requiring more than 2 Zones, the FR4000 and FR8000 Fire Detection unit are the perfect choice, providing an intelligent networked solution, and utilising the same Apollo ‘ORBIS” Marine approved detection devices. This 100mm x 100mm unit features an 8 line Blue backlit LCD display making for easy reading in most lighting conditions. FR-8000 Master Control Unit Features include: Full indication from one central location on your boat. Visual indication of Fire or Fault. Audible indication of Fire or Fault. Isolate any zone. All zone names programmable e.g. (Saloon) (Engine Room) (Upper Deck) (Master Cabin). Blue Backlight FR-100 Input module: Zone controller which manages the sensors. Features include: 8 separate zone inputs. Output Relay’s x 2. 10 A resistive @ 24VDC. Relay 1 & relay 2 close on Fire detection. Relay 1 opens when alarm is muted. Relay 2 opens when all zones are OK. The FR-8000 has been developed to allow monitoring of up to 8 zones. Each zone can have up to 18 sensors attached. It is a network system consisting of the FR-8000 Master Display Unit and one FR-100 Eight Zone Inputs. All devices are interconnected by a 2 wire network cable. The Master Display Unit (MDU) controls communica- tion with all attached Input and Output units. The network cable can be up to 1000 meters in length. GENERAL ALARM TONE GENERATOR As most low cost non-marine approved fire detection system do not include a function for producing a General Alarm warning, Fireboy-Xintex has produced an Add-On General Alarm Tone Generator, which can be wired to the outputs of our own FR-1000/2000 series of detection systems or any other system producing an output to sounders. The General Alarm Tone, or to give it’s correct title, SOLAS Tone 1a consists of 7 short blasts followed by one long blast, indicating when sounded that ALL personnel should proceed to their muster points. Din Rail verticall mounted 79x101x22 Blend of PC/ABS self extinguishing material Green or Black, but special colours are available on request. 24Vdc Product Code 94213 page 5 www.fireboy-xintex.co.uk www.fireboy-xintex.com [email protected] PLEASURE CRAFT & Modular Marine 12 Zone SMALL COMMERCIAL Cont.... +44 (0)845 389 9462 Conventional Detection System (for <24m vessels not requiring marine approvals) This stylish fire detection system will not look out of place on any of todays modern pleasure vessels, designed to give ultimate protection at an affordable cost, but with the styling that merits inclusion on todays modern helm, and the satisfaction of knowing the boat and it’s occupants are protected. The detection module will accomodate any conventional type detectors but has been tested throughout using Apollo Marine Approved Orbis devices. The detection module is also designed to be supplied separately for inclusion within a boats Alarm and monitoring system, with either RS485, RS232 or Modbus protocol versions being available WHEELHOUSE GALLEY SALOON FWD DOUBLE CABIN GUEST CORRIDOR PORT TWIN CABIN STBD DOUBLE CABIN MASTER STATE ROOM CREW CABIN ENGINE ROOM CARBON MONOXIDE NOT USED Display Detection Module Features Technical Up to 12 Zones reporting OK, Fault & Fire Construction - ABS Fault & Fire output relays IP Rating Finish - IP65 Detection module available separately Colour - lid & box - Black RS232, RS485 & Modbus protocols available. Detection Module IP66 Colour - controls plate & labels - Black - fine texture Display IP66 Front IP67 Back Power supply DC rating - 9-32Vdc 1.5A Amps 5 Tactile Buttons Fault contact rating - 30V DC 1 Amp Internal Buzzer Alarm contact rating - 30V DC 1 Amp Software Updates via email Detection zone EOL resistor - 4K7 High brightness QVGA (320 x 240 pixels) colour display. Fully sunlight viewable and the unit is totally sealed. Display Dimensions - 116mm x 166mm x 50mm Operating Temperature - -40 to +70 Degrees Celcius Storage Temperature - -40 to +80 Degrees Celcius WHEELHOUSE GALLEY SALOON FWD DOUBLE CABIN GUEST CORRIDOR PORT TWIN CABIN STBD DOUBLE CABIN MASTER STATE ROOM CREW CABIN ENGINE ROOM CARBON MONOXIDE NOT USED page 6 www.fireboy-xintex.co.uk www.fireboy-xintex.com [email protected] GAS DETECTION +44 (0)845 389 9462 X2 panels offer user-friendly, reliable operation off-shore, on ships and in other maritime applications. With black frame and nautical society certifications, panels are suitable for mounting on the bridge, in the engine room and inside cabins Remote I/O Available in screen sizes 4”, 7”, 10”, 12” & 15” FnIO - S MODBUS ST-3114 ST-2748 RS485 NA-9473 STATUS STATUS MOD 0 1 0 1 RxD 2 3 2 3 In gas detection, ‘Flammable gases or vapours’ is usually shortened to LEL which TxD Analog GND 4 5 stands for ‘Lower Explosive Limit’ – the lowest concentration of a gas which can I/O produce fire in the presence of an ignition source.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    20 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us