King Edward Memorial Park Foreshore

King Edward Memorial Park Foreshore

Thames Tideway Tunnel Thames Water Utilities Limited Application for Development Consent Application Reference Number: WWO10001 Planning Statement Doc Ref: 7.01 Appendix T APFP Regulations 2009: Regulation 5(2)(q) Appendix T Hard copy available in Box 44 Folder B January 2013 This page is intentionally blank Thames Tideway Tunnel Planning Statement Appendix T: King Edward Memorial Park Foreshore List of contents Page number T.1 Introduction ...................................................................................................... 1 T.2 Site description ................................................................................................ 1 T.3 Planning context .............................................................................................. 3 T.4 Description of development ............................................................................ 4 Overview ............................................................................................................ 4 Application for development consent ................................................................. 5 Construction ....................................................................................................... 6 Site set-up .......................................................................................................... 8 Shaft construction .............................................................................................. 9 Tunnel works .................................................................................................... 10 Secondary lining of shaft .................................................................................. 10 Construction of other structures ....................................................................... 10 Completion of works and site restoration ......................................................... 11 Operation ......................................................................................................... 12 CSO drop shaft ................................................................................................ 12 Chambers and culverts .................................................................................... 12 River wall ......................................................................................................... 12 Ventilation structures ........................................................................................ 12 Electrical and control kiosk ............................................................................... 13 Permanent restoration and landscaping ........................................................... 13 Access and movement ..................................................................................... 14 Typical maintenance regime ............................................................................ 14 Scheme development ...................................................................................... 15 T.5 Site-specific planning considerations .......................................................... 19 Meeting the need ............................................................................................. 19 Good design ..................................................................................................... 20 Minimise encroachment in the foreshore ......................................................... 22 Minimise temporary construction impacts on the park ..................................... 22 Sensitive design to reflect the park and riverside setting ................................. 24 Planning Statement ii Enhance the setting of local heritage assets .................................................... 24 Provide a permanent beneficial addition to the park ........................................ 25 Conclusions...................................................................................................... 25 Water quality and resources............................................................................. 26 Flood risk ......................................................................................................... 26 Air quality, emissions, dust and odour .............................................................. 28 Biodiversity and geological conservation ......................................................... 29 Landscape and visual impacts ......................................................................... 30 Land use including open space, green infrastructure and green belt ............... 31 Noise and vibration .......................................................................................... 34 Historic environment ........................................................................................ 35 Light..................................................................................................................36 Traffic and transport ......................................................................................... 37 Waste management ......................................................................................... 40 Socio-economic ................................................................................................ 40 T.6 Overall conclusions ....................................................................................... 41 Annex T.1: Consideration of alternative sites ...................................................... 45 Annex T.2: Drawings for King Edward Memorial Park Foreshore ...................... 49 List of figures Page number Figure T.1 Aerial photograph of King Edward Memorial Park Foreshore ................... 2 Figure T.2 Visualisation of King Edward Memorial Park Foreshore ............................ 5 Figure T.3 Construction timeline ................................................................................. 7 Figure T.4 Functional components diagram ............................................................. 11 Figure T.5 Visualisation of phase one consultation design ....................................... 15 Figure T.6 Visualisation of phase two consultation design ....................................... 17 Figure T.7 Estimated construction barge histogram ................................................. 38 Figure T.8 Estimated construction HGV histogram ................................................... 39 List of tables Page number Table T.1 King Edward Memorial Park: Drawings that define the proposed development ............................................................................................................... 5 Planning Statement iii Appendix T: King Edward Memorial Park Foreshore Appendix T: King Edward Memorial Park Foreshore T.1 Introduction T.1.1 In an average year, the North East Storm Relief Sewer combined sewer overflow (CSO) discharges approximately 782,000m3 of untreated sewage into the River Thames in front of King Edward Memorial Park in the London Borough of Tower Hamlets. The CSO discharges approximately 31 times a year and releases 200 tonnes of sewage derived litter. T.1.2 A worksite is required to connect the North East Storm Relief Sewer CSO to the main tunnel. The proposed development site is known as King Edward Memorial Park Foreshore, which is located in the London Borough of Tower Hamlets. The location of the site is illustrated in Annex T. T.1.3 This assessment is structured as follows: a. Section T.2 provides a brief description of the King Edward Memorial Park Foreshore site. b. Section T.3 sets out the planning context for works in this location. c. Section T.4 describes the site-specific development for which consent is sought and how the proposals evolved through consultation. d. Section T.5 analyses the principal site-specific planning considerations and how the proposals comply with relevant planning policy. e. Section T.6 provides an overall conclusion of the site-specific assessment for the proposed works at the site. T.2 Site description T.2.1 The proposed development site comprises the foreshore of the River Thames adjacent to King Edward Memorial Park and an area in the south of the park, including hard-surfaced sections of the Thames Path, an area of green space, and part of the multipurpose sports pitches to the west. An aerial photograph of the site is provided in Figure T.1 overleaf. T.2.2 The site is bounded by King Edward Memorial Park and The Highway to the north, the residential Free Trade Wharf building to the east, the River Thames to the south, and by the Shadwell Basin Outdoor Activity Centre and Glamis Road to the west. There is an existing jetty and decking in the river adjacent to the Free Trade Wharf to the east. T.2.3 The North East Storm Relief sewer runs beneath park in a southeasterly direction and discharges into the River Thames through the river wall. The CSO point is marked by three large openings in the river wall. The foreshore in this location is exposed when the tide is low, with a mean low water mark some 30m from the river wall. The River Thames in this location is characterised by a wide expanse of water, moored and passing vessels, and piers and structures situated in-river. Planning Statement T-1 Appendix T: King Edward Memorial Park Foreshore Figure T.1 Aerial photograph of King Edward Memorial Park Foreshore T.2.4 The Rotherhithe Tunnel passes beneath the park in a northeasterly direction and emerges in Limehouse. The presence of this road tunnel is marked by the ventilation building in the southern portion

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    64 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us