Beijing Milan Window Energy Saving Building Materials Co.,Ltd, ID

Beijing Milan Window Energy Saving Building Materials Co.,Ltd, ID

Passive House Institute CERTIFICATE Dr. Wolfgang Feist Certified Passive House Component 64283 Darmstadt Component-ID 0828wi03 valid until 31st December 2021 Germany Category: Window Frame Manufacturer: Beijing Milan Window Energy Saving Building Materials Co.,Ltd, BEIJING, China Product name: Passiv 115 This certificate was awarded based on the following criteria for the cool, temperate climate zone 2 Comfort UW = 0.80 ≤ 0.80 W/(m K) 2 UW ;installed ≤ 0.85 W/(m K) 2 with Ug = 0.70 W/(m K) Hygiene fRsi=0.25 ≥ 0.70 cool, temperate climate phB Passive House CERTIFIED phE phD phC phB phA efficiency class COMPONENT www.passivehouse.com Passive House Institute Beijing Milan Window Energy Saving Building Materials Co.,Ltd baishan lndustrial Park Changping Distrct, 102211 BEIJING, China T +861080726999 | B [email protected] | Í http://www.milanwindows.com | o 20 C o 18 C o 16 C o 14 C o 12 C o 10 C o 8 C o 6 C o 4 C o 2 C o 0 C o -2 C o -4 C o -6 C o -8 C o -10 C Calculation model Isothermal Description Timber frame (larch 0.13W/(mK)) insulated by PU (0.036W/(mK)). Glazing: 5/18/5/18/5 Pane thick- ness: 51 mm (5/18/5/18/5), rebate depth: 15 mm, spacer: SWISSPACER Ultimate Explanation 2 The window U-values were calculated for the test window size of 1.23 m × 1.48 m with Ug = 0.70 W/(m K). If a higher quality glazing is used, the window U-values will improve as follows: 2 Glazing Ug = 0.70 0.64 0.58 0.52 W/(m K) # # # # 2 Window UW = 0.80 0.76 0.72 0.68 W/(m K) Transparent building components are classified into efficiency classes depending on the heat losses through the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, and the glazing edge lengths are included in these heat losses. A more detailed report of the calculations performed in the context of certification is available from the manufacturer. The Passive House Institute has defined international component criteria for seven climate zones. In principle, components which have been certified for climate zones with higher requirements may also be used in climates with less stringent requirements. In a particular climate zone it may make sense to use a component of a higher thermal quality which has been certified for a climate zone with more stringent requirements. Further information relating to certification can be found on www.passivehouse.com and passipedia.org. 2/4 Passiv 115 www.passivehouse.com Frame width U-value frame Ψ-panel edge Temp. Factor Frame bf Uf Ψg fRsi=0.25 values mm W/(m2 K) W/(m K) [-] Top (to) 119 0.81 0.025 0.73 Side (s) 119 0.81 0.025 0.73 Bottom (bo) 119 0.81 0.025 0.73 Mullion (m1) 170 0.90 0.025 0.73 1 casement Spacer: SWISSPACER Ultimate Secondary seal: Polysulfid Validated installations Exterior insulation and finishing Formwork blocks (operable) Lightweight timber (operable) system (EIFS) (operable) Ψinstall W/(m K) Ψinstall W/(m K) Ψinstall W/(m K) Top 0.004 Top 0.014 Top 0.004 Side 0.004 Side 0.014 Side 0.004 Bottom 0.012 Bottom 0.022 Bottom 0.013 2 2 2 UW ;installed = 0.81 W/(m K) UW ;installed = 0.84 W/(m K) UW ;installed = 0.81 W/(m K) Component-ID: 0828wi03 3/4 www.passivehouse.com www.passivehouse.com.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us