Airside Economizer – Comparing Different Control Strategies and Common Misconceptions

Airside Economizer – Comparing Different Control Strategies and Common Misconceptions

ESL-IC-08-10-54 Airside Economizer – Comparing Different Control Strategies and Common Misconceptions Jijun Zhou, PE Guanghua Wei, PE W. Dan Turner, PhD, PE David E. Claridge, PhD, PE Texas A&M University College Station, Texas 4. Is it necessary for the outside air enthalpy to be lower ABSTRACT than the return air enthalpy to enable the economizer and Air-side economizer is broadly adopted in building save energy? HVAC design and operations. When the system is properly 5. What happens if the economizer control fails? What designed and the control sequence is properly implemented, are the potential penalties? air-side economizer provides significant energy savings. The design and operation basics of the air-side economizer are well understood and documented. However, some confusion and misconceptions do exist and are widely spread. When INTRODUCTION the economizer is not designed or implemented properly, an Air-side economizer, in short, is to introduce more air handler cannot take the full advantage of "free cooling", outside air flow than required by ventilation needs, to and, in some cases, could even cause significant energy supplement or eliminate the mechanical cooling, when the waste. outside air is cool enough to make it possible. Besides common components of a typical air-handling unit such as a This paper first introduces the fundamentals of the air- cooling coil, a preheating coil and a supply fan (possibly side economizer and the typical control sequences. It goes with a Variable Frequency Drive, or VFD), a system with on to discuss the determination of the activation temperature full economizer capability usually consists of a modulating that enables or disables the dry-bulb temperature based return air damper as well as a modulating outside air economizer operation. The “best” activation temperatures damper. In larger systems, a modulating relief damper is also that maximize the energy savings can be calculated based on required to control building pressure. weather data and are different from location to location. The activation temperatures for a few representative cities are presented. For drier weather regions, the activation temperatures are significantly higher than those for hot and humid weather regions. The second part of the paper discusses the benefits of the enthalpy-enabled economizer and points out some important misconceptions that could significantly impact the energy savings of the economizer operation. Specifically, it challenges the simplistic control strategy for the enthalpy- based economizer control that is commonly used in the industry. Some of the questions this paper tries to answer Figure 1. SDVAV unit with full economizer capability include: 1. What is the optimal activation temperature for a Figure 1 shows the schematic of a typical air-handling temperature-based economizer that provides the most unit (AHU) with full economizer capability. The unit has energy savings? both a minimum outside air damper (typically open/close 2. How does enthalpy-based economizer compare with control only) and an economizer outside air damper. The the temperature-based economizer in energy savings? relief air damper and the return air damper are linked 3. Does an economizer always save energy when the together so that as one opens, the other one closes. Under outside air enthalpy is below the return air enthalpy? normal operation mode, the economizer damper is kept fully Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 ESL-IC-08-10-54 closed, the minimum outside air damper is open, the return Typical Meteorological Year (TMY) weather data for damper is fully open, and the relief damper is fully closed. Houston (hot and humid) and Denver (cool and dry) are The supply fan speed is modulated to maintain the duct displayed on psychrometric charts. There is no surprise that static pressure and the return fan speed may be controlled to the Denver weather is much cooler and drier than Houston. track the supply air flow with some offset. Since the relief What is less obvious is that under the same outside air damper is closed, the difference between the supply and the temperature, e.g., 65°F (18.3°C), the average outdoor air return airflows equals to the amount of outside air flow. enthalpy in Denver (22.3 Btu/lb, or 51.9 kJ/kg) is considerably lower than that is in Houston (27.4 Btu/lb, or When economizer operation is enabled, the economizer 63.7 kJ/kg). Therefore, running in the economizer mode damper, together with the return air damper and the relief air when outside air is 65°F (18.3°C) (and under) seems to be an damper are modulated in sequence with the cooling coil energy efficient move in Denver while it is probably not a chilled water valve to control the discharge air temperature good idea in Houston. In many real-world applications, the at its setpoint. Provisions have to be made to prevent all activation temperature is often set as low as 55ºF (12.8°C) to devices from fighting with each other. If the discharge be “safe”. temperature is higher than its setpoint, the economizer damper will open more to introduce more outside air (free cooling) to help reduce or eliminate mechanical cooling TMY Weather Data (Houston, TX) provided by the cooling coil. As the economizer damper 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 0.03 0.03 fully opens, if the discharge air temperature is still higher 90% 0.028 80% 0.028 50 than its setpoint, the return air damper will start to close to 0.026 70% 0.026 60% 0.024 0.024 force even more outside air to enter the system. The chilled 45 50% 0.022 0.022 water valve should not start to open until the economizer 40% 0.02 40 0.02 damper has been fully opened and the return air damper 0.018 0.018 30% 1 35 fully closed (or closed to its control limit ). 0.016 0.016 0.014 0.014 30 0.012 20% 0.012 0.01 25 0.01 0.008 0.008 ECONOMIZER ACTIVATION STRATEGIES air) dry (Lb/Lb Humidity Abs. 20 0.006 0.006 10% 15 The economizer control mode is typically enabled or 0.004 0.004 disabled based on outside air dry-bulb temperature 0.002 0.002 0 0 (temperature-based economizer) or outside air enthalpy in 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 Dry Bulb Temperature (deg F) comparison with the return air enthalpy (enthalpy-based economizer). The most often-used activation strategy is simply based on the outside air dry-bulb temperature. This is Figure 2. Houston weather data on Psychrometric chart because the key sensors required for the enthalpy-based economizer, i.e. the outside air relative humidity (RH) sensor and particularly the return air RH sensors, are often TMY Weather Data (Denver, CO) not available or unreliable. The maintenance and the 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 0.03 0.03 90% accuracy of the RH sensors are also a major concern in 0.028 80% 0.028 50 0.026 70% 0.026 implementing the enthalpy-based economizer. 60% 0.024 0.024 45 50% 0.022 0.022 40% For the temperature-based economizer, the activation 0.02 40 0.02 0.018 0.018 30% temperature is the outside air temperature at which the 35 0.016 0.016 economizer mode is activated. The determination of the 0.014 0.014 30 activation temperature, however, is rather arbitrary. The 0.012 20% 0.012 ASHRAE handbook (2007) points out that the activation 0.01 25 0.01 0.008 0.008 Abs. Humidity (Lb/Lb dry air) dry (Lb/Lb Humidity Abs. 20 0.006 0.006 temperature may be significantly lower than the return air 10% 15 temperature in humid climates where latent ventilation loads 0.004 0.004 0.002 0.002 are significant. However, in dry climates, the activation 0 0 temperature may be close to the return temperature. This is 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 Dry Bulb Temperature (deg F) obvious when looking at Figure 2 and Figure 3, where Figure 3. Denver weather data on Psychrometric chart 1 It is possible that closing the return damper to certain limit will force the supply air fan to speed up if the outside air duct is relatively small comparing to the return duct. Therefore it is necessary to enforce a control limit for the return air damper. Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 ESL-IC-08-10-54 The economizer saves energy when it takes less energy “minor” for Denver to “devastating” for Houston and (sensible and latent) to cool down the outside air to the Miami. discharge air temperature setpoint than the return air. Hour- by-hour energy consumption for economizer vs. non- economizer operations can be calculated and compared over Economizer savings under different OAT a typical meteorological year for each location (city). Energy 1,500.00 savings (defined as the difference between the mechanical cooling energy consumption for economizer and non- 1,000.00 economizer operations) can be summed up for each 1°F 2 outside air temperature bin , as shown in Figure 4 for 500.00 Phoenix, Arizona. Bt u/ Lb - As shown in Figure 4, the economizer energy savings 26.0 33.0 41.0 45.0 49.0 53.0 57.0 61.0 65.0 69.0 73.0 77.0 81.0 85.0 89.0 93.0 97.0 (500.00) 101.0 105.0 112.0 are positive when the outside air temperature is below 70°F and become negative (energy penalty) as the temperature (1,000.00) gets higher.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    5 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us