1 Total Microscale Analytical Chemistry

1 Total Microscale Analytical Chemistry

3rd. International Microscale Chemistry Symposium México.2005 1 TOTAL MICROSCALE ANALYTICAL CHEMISTRY: PRECISION DATA IN VOLUMETRIC TITRATIONS Alejandro Baeza, Adrián de-Santiago, Eduardo Galicia , Irissol Hernández and Ricardo Lopez Analytical Chemistry Department. Faculty of Chemistry. National University of Mexico, UNAM. Mexico City PC 04510. [email protected] http//mx.geocities.com/electrokimica Microscale laboratory has been widely used in General Chemistry mainly in Synthetic Chemistry (inorganic and organic chemistry). Analytical Chemistry approaches just concern to titrimetric determinations with acid-base indicators using 5 mL pipets as burets to teach semi quantitative analysis aspects. Teaching Veq,: mean, standard deviation and Analytical Chemistry requires to focus in variation coefficient per cent, (s.d./x)100: quality aspects such as accuracy and VCP are determined. precision. This latter is the most affected when microscale conditions are assayed: Results obtained are shown bellow “to microtechniques, macroerrors”. compared with those obtained for two However if good experimental practices commercial 25 and 10 mL burets[1]: are observed these errors can be controlled and minimized to yield an Buret mean s.d. VCP adequate and good experimental teaching experience. 25 mL Veq.(mL) 14.72 0.3858 2.62 In this work we show that results 10 mL obtained with low cost equipment with Veq.(mL) 5.897 0.1140 1.94 locally materials are equivalent to those 1 mL obtained in macroscale conventional Veq.(mL) 0.561 0.0058 1.03 conditions respect to precision parameters assayed. Volumetric titrations results are Additionally a calibration curve was shown monitored by colored chemical performed to measure the real volume indicators or instrumentally poured by 1 mL microburet (by weighting (micropotentiometry or conductimetry). the poured water in analytical balance) respect to marked volume in the buret body : DV = (Vmarked-Vmeasured) versus the Experimental results marked volume. Figure in the next page shows that DV is Figure below shows the 1 mL buret used around ± 0.00791 mL for 0.5 mL as to determined the equivalent point equivalent volume (1.6%). For a 50 mL volume when titrating aliquots of 0.01 buret a V = 30 mL shows a 0.1% mol/L HCl with normalized 0.01M deviation[2]. NaOH using phenolphthalein as indicator. 3rd. International Microscale Chemistry Symposium México.2005 2 V = f (V ) DD marked For n= 30 next results were obtained: 0.01 (A) (B) 0.01 D D V , [mL] marked mean 0.0990 mL 0.0980 mL 0.00 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 s.d. 0.0011 0.0008 -0.01 VCP 1.16% 0.84% -0.01 -0.02 -0.02 End point monitoring potentiometrically -0.03 were performed with low cost -0.03 microelectrodes: Wº or PANI as pH [3,4] -0.04 sensors in aqueous and non aqueous -0.04 solvents, Cº for redox and complexometric titrations and Agº for halide titrations[5]. A redox titration of 0.5 mL 0.1N sodium tiosulphate with KMnO4 0.1 N was Next figure shows typical average additionally performed . The average Veq potentiometric titrations: (a) pH non found was 0.61 mL± 0.01 (n=17, VCP = aqueous solution titration of 1 mL of 1.99%). Visual indication was used. 0.2M 2-6 lutidine with 0.4 M methane sulphonic acid with a PANI micro pH In all cases above, insulin syringes were sensor in acetonitrile as solvent (n=5): used to deliver 0.5 mL samples to titrate. In order to know the precision associated to these syringes used as pipetting pH devices, measurements of the weight of 19 (a) water delivered with a 1 mL insuline syringe were performed and compared with those obtained with a commercial automatic pipet. The figure below show 16 the pipets assayed. 13 10 7 0 200 400 600 800 1000 1200 [mL] and (b) 0.5 mL of 0.1 M NaCl with 0.1 M AgNO3 with a silver rod microsensor with no salt bridge separation (n=10): (A) (B) 3rd. International Microscale Chemistry Symposium México.2005 3 (b) 7.00 pe 900 800 6.00 700 5.00 600 500 4.00 E(mv) 400 3.00 300 200 2.00 100 [ mmL] de Ag(I) 1.00 0 0 100 200 300 400 500 600 700 800 900 0 0.2 0.4 0.6 0.8 1 mL note: pe = E(mV)/60 (mV) Conclusions Next figure shows the microsensors used Precision in microscale conditions is suitable enough to ensure a good Reference experimental teaching in volumetric Wº Electrode analysis. Cº References 1) Alejandro Baeza “Microbureta a Microescala Total para Totulometría” Rev. Chil. Educ. Cient. 1[2](2003)4-7 Finally a conductimetric experimental set 2) Daniel C. Harris. Quantitative Chemical Analysis.” Fifth Edition. W.H. Freeman and up design in our laboratory is used to Co.(1998)55i. determine the equivalence point in acid- base titrations. C and W rods use for 3) Alejandro Baeza “Titulaciones ácido-base Potenciométricas a potentiometry can be used as conductors Microescala Total con Microsensores de pH y connected to a oscillographic interphase de Referenciade Bajo Costo” to measure the conductivity of the titrated Rev. Chil. Educ. Cient. 1[2](2003)16-19 solution. Figures below show the 4) Juan Vargas, Alejandro Baeza, Tatiana experimental set up used and a typical Urzúa, Jorge Rodríguez, Lizethly Cáceres. 0.1M HCl-0.1 M NaOH conductimetric “Titulaciones ácido-base a Microescala Química usando Microsensores de pH y titration average plot (n=10). Microelectrodo de Referencia: Adquisición de Datos con nuevas Tecnologías- Rev. Chil. Educ. Cient. 2[2](2004)25-29 5) Alejandro Baeza. Adrián de Santiago, Eduardo Galicia. “Titulaciones de Halogenuros a microescala Total con Microsensores de Ag y de Microrefrencia de Bajo Costo Sin Puente Salino” Rev. Chil. Educ. Cient. 3[[1]](2004)22-25 3rd. International Microscale Chemistry Symposium México.2005 4 .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us