Studies on Mass Attenuation Coefficient, Mass Energy Absorption

Studies on Mass Attenuation Coefficient, Mass Energy Absorption

Turkish Journal of Physics Turk J Phys (2015) 39: 81 { 90 http://journals.tubitak.gov.tr/physics/ ⃝c TUB¨ ITAK_ Research Article doi:10.3906/fiz-1408-4 Studies on mass attenuation coefficient, mass energy absorption coefficient, and kerma for Fe alloys at photon energies of 17.44 to 51.70 keV Demet YILMAZ∗, Yusuf S¸AHIN,_ L¨utf¨uDEMIR_ Department of Physics, Faculty of Sciences, Atat¨urkUniversity, Erzurum, Turkey Received: 05.08.2014 • Accepted: 17.09.2014 • Published Online: 23.02.2015 • Printed: 20.03.2015 Abstract: The mass attenuation coefficient (µm), the mass energy absorption coefficient (µen/ρ), and kerma relative to air were determined for some alloys, namely Fe 0:5 Cr 0:5 , Fe 0:7 Cr 0:3 , Fe 0:8 Cr 0:2 , Fe 0:9 Cr 0:1 , Fe 0:2 Ni 0:8 , Fe 0:3 Ni 0:7 , Fe 0:5 Ni 0:5 , Fe 0:6 Ni 0:4 , Fe 0:7 Ni 0:3 , and Fe 0:8 Ni 0:2 , at 17.44, 19.63, 22.10, 24.90, 32.06, 36.39, 37.26, 43.74, 44.48, 50.38, and 51.70 photon energies by using an HPGe detector with a resolution of 182 eV at 5.9 keV. The experimental results of µm were compared with the theoretical results. The theoretical values of µen/ρ were compared with the semiempirical values. It was observed that kerma values relative to air values were different in Fe{Ce and Fe{Ni alloys due to photoelectric cross sections depending on the atomic numbers of the material. Key words: Mass attenuation coefficient, mass energy absorption coefficient, kerma 1. Introduction The application of stainless steel alloy in nuclear reactors, modern technology, archeology, and petroleum plants prompts investigation of physical parameters such as the mass attenuation coefficients, the mass energy absorption coefficients, kerma, total atomic and electronic cross-sections, and effective atomic and electron numbers. The mass attenuation coefficient is an essential parameter for gamma ray interactions with the material. The mass attenuation coefficient (µm) is a measure of the average number of interactions between incident photons and matter occurring in a given mass-per-unit area thickness of the substance encountered [1]. The mass energy absorption coefficients of materials are important in several applications of medical physics, nuclear science, radiation physics, radiotherapy, irradiation technology, and radiation biology. The absorbed dose in a medium is measured by the mass energy absorption coefficient (µen/ρ). The photon energy transferred depends on the photon interaction process (photoelectric effect, Compton scattering, and pair production). Thus, µen/ρ is affected by atomic numbers of material and photon energy. Kerma (kinetic energy released per unit mass) is defined as the initial kinetic energy of all secondary charged particles released per unit mass at a point of interest by uncharged radiation. It is applicable to photons (X-ray, gamma ray, bremsstrahlung, etc.) and neutrons. In the kerma approximation, the effects induced by photons in the chemical content analysis are often scaled in terms of the absorbed dose (collision kerma). Various researchers have calculated and measured mass attenuation coefficients and mass energy absorp- tion coefficients. Han and Demir investigated mass attenuation coefficients, and effective atomic and electron numbers of Ti and Ni alloys [2]. Saim et al. investigated mass attenuation coefficients, and effective atomic ∗Correspondence: [email protected] 81 YILMAZ et al./Turk J Phys and electronic numbers of Cd 1−x Zn x Te alloys in the gamma ray energy region from 10 to 100 keV [3]. The mass attenuation coefficients for 22 high purity elemental materials were measured in the X-ray energy obtained by a variable energy X-ray source range from 13 keV to 50 keV using a high purity germanium detector [4]. Onder¨ et al. obtained mass attenuation coefficients, effective atomic numbers, and electron densities for TLD compounds [5]. Parthasaradhi et al. determined mass attenuation coefficients of tissue equivalent samples in the energy range of 13{44 keV [6]. Manjunathaguru and Umesh determined effective atomic numbers of sev- eral biologically important compounds [7]. Akkurt obtained effective atomic numbers for Fe{Mn alloy using a transmission experiment [8]. Hubbell calculated µen/ρ theoretically for elements and compounds from 1 keV to 20 MeV [9]. Singh et al. investigated energy absorption coefficients for 662 keV gamma rays in some compounds [10]. Seltzer calculated the mass energy-transfer and mass energy absorption coefficients for 1 keV to 100 MeV [11]. The photon energy absorption coefficients of complex molecules such as carbohydrates, proteins, lipids, and vitamins in energy of 200{1500 keV were investigated by Manjunathaguru and Umesh [12]. The energy absorption coefficients in some fatty acids were studied in energy of 662 and 1115 keV by Bhandal et al. [13]. The mass energy absorption coefficients and mass collision stopping powers for electrons in tumors were studied [14]. Shakhreet et al. measured µen/ρ of paraffin, wax, and gypsum at 662 keV photon energy [15]. Kerma and air kerma are important in radiographic images for image quality. Go¸calves et al. investigated the effects of aluminum{copper alloy filtration on photon spectra by air kerma rate [16]. In the present work, mass attenuation coefficients were measured for Fe 0:5 Cr 0:5 , Fe 0:7 Cr 0:3 , Fe 0:8 Cr 0:2 , Fe 0:9 Cr 0:1 , Fe 0:2 Ni 0:8 , Fe 0:3 Ni 0:7 , Fe 0:5 Ni 0:5 , Fe 0:6 Ni 0:4 , Fe 0:7 Ni 0:3 , and Fe 0:8 Ni 0:2 alloys at 17.44, 19.63, 22.10, 24.90, 32.06, 36.39, 37.26, 43.74, 44.48, 50.38, and 51.70 photon energies by using an HPGe detector with a resolution of 182 eV at 5.9 keV. The values of µen/ρ were taken from the compilation of Hubbell and Seltzer [17]. Moreover, the mass energy absorption coefficients were calculated using a semiempirical approximation for the low energy region. The kerma relative to air was computed and reported in the present work. 2. Theoretical background and computational method The mass attenuation coefficients for materials can be determined by radiation transmission method according to Lambert{Beer's law: I = I0 exp [−µmt] ; (1) 2 where µm is the mass attenuation coefficient (cm /g), I0 is incident photon intensity, I is attenuated photon intensity, and t is the mass thickness of the material. The theoretical µm values for the present alloys were obtained by the WinXCom code [18]. This program depends on the use of the mixture rule to calculate the partial and total mass attenuation coefficients for all elements, compounds, and mixtures at standard as well as selected energies. The mass energy absorption coefficient is the amount of incident photon energy transferred to kinetic energy changed particles by gamma ray interaction [19]. The mass energy absorption coefficient (µen/ρ) is defined by Ψ(J m −2). Ψ is the energy fluence of monoenergetic photons passing normally through an area Ain an absorber. Moreover, kerma is the energy transferred to charged particles in a volume. Kerma is ( ) ΨAµ dx µ K = en = Ψ en (2) ρAdx ρ 82 YILMAZ et al./Turk J Phys Therefore, kerma is the product of the energy fluence and the mass energy absorption coefficient. Kerma of an alloy relative to air can be expressed as (µen/ρ)Alloy KAlloy Ka = = (3) (µen/ρ)Air KAir In order to compute kerma relative to air, the values of mass energy absorption coefficients of air and alloys were calculated using the following equation: ( ) µ X µ en = w en ; (4) ρ i ρ i i where wi and (µen/ρ)i are the weight fraction and the mass energy absorption coefficient of the ith constituent element present in a material. 3. Experimental details The experimental setup used in the present study is shown in Figure 1. The source{sample and sample{detector distances were set to 30 mm and 30 mm, respectively. Sharanabasappa et al. suggested the transmission range 0.5 ≥ T ≥ 0.02 for HPGe detectors [20]. A variable energy X-ray source from Amersham (AMC.2084) was used in order to irradiate the alloys at energies of 17.44, 19.63, 22.10, 24.90, 32.06, 36.39, 37.26, 43.74, 44.48, 50.38, and 51.70 keV. This source contains a sealed ceramic primary source, 241 Am (intensity of 10 mCi), that excites characteristic X-rays from 6 different targets (Cu, Rb, Mo, Ag, Ba, and Tb) in turn (Figure 2). Photon intensities were measured using the HPGe detector. The HPGe detector is a DSG planar high purity germanium crystal with a diameter of 16 mm, a length of 10 mm, a beryllium window of 0.12 mm, and an active area of 200 mm 2 . A bias voltage of {1500 V was applied to the detector with a resolution of 182 eV at 5.9 keV. Source Source Target Pb sh!eld Pb sh!eld HPGe detector Figure 1. Experimental setup. The spectra were recorded using by a Canberra (AccuSpec) PC-based multichannel analyzer card. The time constant of the Ortec model 472 amplifier was set to 6 µs, ensuring optimum detector performance as specified by the manufacturer. Operating parameters of the system were governed and controlled by the 83 YILMAZ et al./Turk J Phys computer program Genie-2000. The pulse height spectra of X-rays were acquired for a period of 300{900 s. Background correction was applied to the data collected in 1024 channel of the MCA.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    10 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us