DOOR CONTROL AND SECURITY HARDWARE 2 Table of Contents Electric Strikes Series 6000 Electric Strikes . 4-11 Strikes for Rim Exit Devices . 5-6 Strikes for Mortise and Cylindrical Locks . 7-11 5100 Electric Strike . 12 Compatibility Charts. 13 Additional Information . 14 Electrical Accessories DE5101 . 22 Electric Mortise Lock . 25 Electric Trim. 15 Electric Mullions. 33 Electrical Power Transfers . 29 Exit Trim - Computer Managed. 26-27 Junction Box . 29 Monitor Strikes. 30-32 Power Supplies . 28 Pushpad. 19 Exit Devices Alarmed Exit Devices . 20-21 ALK Exit Alarm Kit. 23 Chexit Delayed Exit . 20-21 Guard-X. 24 Exit Devices (Electric Latch Retracting) . 16 Exit Devices— Monitoring . 17-19 Additional Information Handing of Doors. 34 Wire Size Selection . 34 3 Series 6000 Electric Strikes Electric Strikes provide remote release OPTIONS Optional of a locked door. They allow the door AC Operation Latchbolt to be opened without retracting the Position SO12 and SO24 are rectifier kits to Tripper latchbolt. This occurs by the releasing of convert AC voltage to operate the the electric strike lip (sometimes called DC solenoids. These kits are field keeper or gate). When the door closes installable and plug in-line to solenoid. the beveled latchbolt rides over the lip Wire Connector and falls into the electric strike pocket. DS and DS-LC — Dual Switch Monitoring (Factory Installed Only) VON DUPRIN SERIES 6000 Dual switch monitoring option has two ELECTRIC STRIKES Lip SPDT contacts, one switch monitors (keeper) Von Duprin is the leading manufacturer the tripper which is depressed when of premium, heavy-duty electric strikes the latchbolt is inserted into the strike known for their reliability, durability and pocket. The second switch monitors Faceplate security. the condition of the strike lip, open or Back closed and locked. Box Versatility • Non-handed DS is standard, rated 24V, operating range from 2 ampere to 50 milliampere. • Furnished 24VDC standard with 12VDC and AC operation optional. DS-LC low volt gold contact switches Solenoid 16V solenoids available. for use on applications associated with • Furnished fail secure (FSE) standard, computer control and monitoring, rated UL LISTED with fail safe (FS) optional. 24V, operating range 50 milliampere UL Listed Burglary-Resistant and Electric or below. • Strike box is adjustable to compensate Strike for fire doors and frames. A label for any misalignment of the door or Fail Secure — FSE for single doors and B label for double frame. FSE — FAIL-SECURE electric strikes doors. Strikes meet the requirements of ANSI 156.5, Grade 1, 1992. • Two piece plug connectors are require power to be applied to unlock the furnished for ease of installation and strike lip. On loss of power, the strike is TO ORDER, SPECIFY for removal during strike servicing. locked. Field convertible with parts. 1. Model number. Fail Safe — FS 2. FS (fail safe, when required). Durability FS — FAIL-SAFE electric strikes require 3. DS or DS-LC (dual switch, when Developed with Von Duprin’s high standards power to be applied to lock the strike lip. required). and engineering expertise. On loss of power, the strike is unlocked. 4. Voltage 12VDC or 24VDC For 16V Solenoids order separately. • Heavy-duty stainless steel construction. Building codes prohibit the use of 5. SO12 or SO24 (required when using AC) • Tested to over 250,000 cycles. fail-safe strikes on labeled openings. 6. Finish: US3, US4, US10, US10B, • 1500 lbs. holding strength. Field convertible with parts. US32, US32D. • 70 lbs. impact strength. Entry Buzzer — EB 7. EB (Entry buzzer), FSE only (when EB — Entry buzzer is available for use To assure the proper selection of an required). electric strike on new applications, with fail-secure strikes. Installed in the lockset compatibility charts are shown frame and in parallel with the circuit, the on page 13. When using a lockset not buzzer will sound when the strike is listed or when retrofitting a strike to an unlocked. existing application, consult Von Duprin Note: Information listed is for use on new for application assistance. applications. On retrofit applications, modification of the frame preparation may be required, consult factory. 4 6111, 6112, 6113 Electric Strikes 6111 FEATURES Electric strike for use with rim exit • Stainless Steel Construction 3 devices on single doors or double doors • Accepts ⁄4˝ (19mm) Throw Latchbolt with mullion applications (hollow metal, • Six Finishes aluminum or wood). Designed to replace • Non-handed Von Duprin 3031. Specify if using with • Fail Secure 55 rim devices. • Horizontally Adjustable • Plug Connectors 6112 Electric strike for use with rim exit OPTIONS devices on single door applications • FS (Fail Safe) (hollow metal, aluminum or wood). • DS or DS-LC (Dual Monitor Switches) 6111 Designed to replace Folger Adam 310-4, • EB (Entry Buzzer) minor frame prep modification required. 6111/6113 ELECTRIC STRIKE 6113 BLADE STOP SHIM 010055-XX Electric strike for use with rim exit devices on single door applications Use on cased opening (hollow metal, aluminum or wood), or blade stop frame. 1 1 ⁄2˝ (13mm) stop or greater. Designed to ⁄2" (13mm) aluminum, replace Von Duprin 3011 and 3021. not for fire door application. Specify if using with 55 rim devices. 6112 6113 SPECIFICATIONS 12V 24V Resistance in Ohms±10% @ 70°F 21 82 UL listed Burglary Resistant Watt-seated @ 70°F 7.5 8 CVXY and Electric Strike for fire doors or frames GXAY (fail secure Amps-seated @ 70°F .6 .33 only). ANSI E59311 Amps-inrush @ 70°F .6 .33 Listing applies to Von Duprin rim devices. DIMENSIONS AND CONFIGURATIONS 6111 6112 6113 3 7 1 5/8" /4" /8" 1 (41mm) /2" 5 (19mm) (22mm) 1 /8" 1 5/8" 15 (13mm) 1 5/8" (41mm) 9 1 /16" (41mm) /16" (49mm) (41mm) (14mm) 6" 2 3/16" 4 1/2" 1 (152mm) 6" 1 4 /2" (56mm) (114mm) 9" 4 1/2" 2 /4" 2 9/16" (152mm) (114mm) (229mm) (114mm) (57mm) (65mm) Minimum 1 3/8" Clearance 3 5 1 /8" (35mm) 1 /8" (35mm) (41mm) Minimum Minimum Clearance 7/8" 7/8" 13 9 Clearance (22mm) /16" /16" (22mm) (21mm) 7/8" (14mm) (22mm) 5 6114, 6121 Electric Strikes 6114 FEATURES Electric strike for use with rim night • Stainless Steel Construction 3 3 latches having up to ⁄4˝ (19mm) bolt • Accepts ⁄4˝ (19mm) Throw Latchbolt throw. Replace Folger Adam 310-5. • Six Finishes • Non-handed 6121 • Fail Secure Electric strike for use with rim exit • Horizontally Adjustable devices on double door applications, • Plug Connectors without mullion (hollow metal, aluminum or wood). Strike mounts on inactive leaf. OPTIONS Replace Folger Adam 310-4-100. • FS (Fail Safe) • DS or DS-LC (Dual Monitor Switches) • EB (Entry Buzzer) SPECIFICATIONS 12V 24V 6114 Resistance in Ohms±10% @ 70°F 21 82 Watt-seated @ 70°F 7.5 8 Amps-seated @ 70°F .6 .33 Amps-inrush @ 70°F .6 .33 6121 UL listed Burglary Resistant CVXY. DIMENSIONS AND CONFIGURATIONS ANSI E59371 6114 6121 2 1/2" (64mm) 1 7/16" (37mm) 1/8" (22mm) 1 5/8" 3 3/32" (41mm) (79mm) 1 5 9 /8" 1 /8" (232mm) 7 1/2" (41mm) (191mm) 6 6210, 6211, 6211AL, 6211WF Electric Strikes 6210 6211WF Electric strike for use with mortise locks Electric strike for use on new without deadbolt on single door, hollow installations with mortise locks metal frame applications and using ANSI without deadbolt or cylindrical locks prep at standard height. Strike pocket on single door, wood frame applications. inserts are provided to accommodate Designed to replace Folger Adam 732. different manufacturers deadlocking FEATURES trigger locations. • Stainless Steel Construction 3 6211 • Accepts ⁄4" (19mm) Throw Latchbolt Electric strike for use on new • Six Finishes installations with mortise locks • Non-handed without deadbolt or cylindrical locks • Fail Secure on single door, hollow metal frame • Horizontally Adjustable 6210 applications. Designed to replace • Plug Connectors Von Duprin 3140 or Folger Adam 712. OPTIONS 6211 6211AL • FS (Fail Safe) Electric strike for use on new • DS or DS-LC (Dual Monitor Switches) installations with mortise locks • EB (Entry Buzzer) without deadbolt or cylindrical locks on single door, aluminum frame applications. Designed to replace Folger Adam 722. SPECIFICATIONS 12V 24V 6211AL Resistance in Ohms±10% @ 70°F 21 82 Watt-seated @ 70°F 7.5 8 UL listed Burglary Amps-seated @ 70°F .6 .33 Resistant CVXY and Amps-inrush @ 70°F .6 .33 Electric Strike for fire 6211WF doors or frames GXAY (fail secure only). ANSI E59321 DIMENSIONS AND CONFIGURATIONS 6210 6211 6211AL 6211WF 15 1 19/16" 1 /32" 1 /4" 1 1/4" (38mm) 1 (49mm) (32mm) (32mm) 1 /4" 1 3/4" (32mm) 1 11/16" (44mm) (43mm) 3 3/8" 3 3/8" 4 7/8" 4 7/8" 4 7/8" (86mm) (86mm) (124mm) (124mm) (124mm) 12" 3 1/4" 1 (305mm) 7 2 /16" (83mm) 12" /8" (52mm) Minimum 7/8" 7/8" (305mm) (22mm) Clearance (22mm) 1 3/8" (22mm) 1 1 /4" 1 1/4" (35mm) 1/8" 1 1/8" 1 (32mm) /2" (32mm) 1/2" /2" (3mm) (3mm) (13mm) (13mm) (13mm) 1 15/32" 1 15/32" 1 (49mm) 1 /4" (49mm) 11 (32mm) 1 /16" 4 1/2" (43mm) (114mm) 3 3/8" 7 3 (86mm) 12" 4 /8" 3 /8" 3 9/16" (305mm) 1 (124mm) (86mm) (90mm) 2 /6" Minimum 1 (52mm) 2 /6" Clearance (52mm) 7/8" 1/8" Minimum (22mm) (3mm) Clearance 1/8" (3mm) 7 6212, 6212WF Electric Strikes 6212 FEATURES Electric strike for use with mortise locks • Stainless Steel Construction 3 without deadbolt or cylindrical locks on • Accepts ⁄4˝ (19mm) Throw Latchbolt single door, hollow metal or • Six Finishes aluminum frame applications. • Non-handed Fits modified ANSI 115.2 cutout.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages36 Page
-
File Size-