Hemodynamics Overview and Terminology

Hemodynamics Overview and Terminology

Hemodynamics Hemodynamics Bioengineering 6000 CV Physiology Overview and Terminology • Parameters – Pressure – Velocity Arterioles – Flow • laminar vs. turbulent – Resistance – Viscosity – Energy – Area – Volume Hemodynamics Bioengineering 6000 CV Physiology Structural Overview Intro to Circulation Bioengineering 6000 CV Physiology Functional Overview Arterial System Bioengineering 6000 CV Physiology Blood Distribution • Velocities/Flows Percent of blood Cross-sectional area volume – Aorta: 30-50 cm/s – Capillaries: 0-1 cm/s Velocity or 5.5 hours/mm3 • Blood mass: 8% of Pressure body mass • Volumes (percent of total blood volume) – Systemic: 83% • Arteries: 11% • Capillaries: 5% Aorta Arteries Arterioles Capillaries Venules Veins Venae • Veins: 67% Cava – Pulmonary: 12% Pressure Velocity – Heart: 5% Cross-sectional area Percent of blood volume Hemodynamics Bioengineering 6000 CV Physiology Velocity vs. Area • Flow is constant throughout • Flow =∫velocity * area Hemodynamics Bioengineering 6000 CV Physiology Hemodynamics Basics • "The problem of treating the pulsatile flow of blood through the cardiovascular system in precise mathematical terms is insuperable" (Berne and Levy) – Blood is not Newtonian (viscosity is not constant) – Flow is not steady but pulsatile – Vessels are elastic, multibranched conduits of constantly changing diameter and shape. – Use equations qualitatively • Local control of blood flow Hemodynamics Bioengineering 6000 CV Physiology Laminar Flow and Turbulence • Laminar flow – Parabolic profile • Pulsatile laminar flow – Velocity changes – May reverse direction • Turbulent flow – Nonaligned movement – Noisy (BP cuff) Velocity Profiles Velocity – Reynolds number • > 1000 = turbulence • > 200 = eddies possible – Rarely occurs in healthy vessels Hemodynamics Bioengineering 6000 CV Physiology Hemodynamic Parameters . P = pressure V = volume Q = flow η = viscosity ∆P • Resistance R = ∆Q˙ ∆V • Compliance C = ∆P ∆P • Inertance L = ∆Q/˙ ∆t ⇡r4 • Poiseuille's Law Q˙ =(P1 P2) – laminar flow − 8⌘l – Newtonian fluid V – rigid tube 8⌘l (I = ) – works for small R = R arteries and ⇡r4 veins Hemodynamics Bioengineering 6000 CV Physiology Hemodynamic Parameters . P = pressure V = volume Q = flow η = viscosity ∆P • Resistance R = ∆Q˙ ∆V • Compliance C = ∆P ∆P • Inductance L = ∆Q/˙ ∆t ⇡r4 • Poiseuille's Law Q˙ =(P1 P2) – laminar flow − 8⌘l – Newtonian fluid V – rigid tube 8⌘l (I = ) – works for small R = R arteries and ⇡r4 veins Hemodynamics Bioengineering 6000 CV Physiology Resistance and Compliance ∆P R = ˙ • Veins vs. arteries ∆Q – have 24 times the Normal compliance of arteries – carry 65% of the blood Blood Flow – have even higher blood 0 100 200 storage capacity Arterial Pressure [mm Hg] • Autonomic control Sympathetic inhibition Sympathetic stimulation – alters resistance but not compliance (slopes of ∆V C = curves) Venous ∆P – acts to shift blood volume Blood Volume Arterial 0 70 140 Pressure [mm Hg] Hemodynamics Bioengineering 6000 CV Physiology Viscosity U F A • Viscosity increases with u y Y – increased hematocrit – constrictions in vessels • Viscosity decreases with ⌧ F/A Shear stress – increased flow velocity ⌘ = = = du/dy U/Y Shear rate – vessel diameter below 300 µm Definition for 10 homogenous Newtonian fluid 8 Poor formula for viscosity in 6 small vessels Blood 4 2 Plasma Viscosity (water=1) Viscosity Water 10 20 30 40 50 60 70 Hematocrit [%] Hemodynamics Bioengineering 6000 CV Physiology Viscosity Hemodynamics Bioengineering 6000 CV Physiology Viscosity Shear Thinning or Thickening? Hemodynamics Bioengineering 6000 CV Physiology Factors that Affect Viscosity • Flow rate: as flow decreases, viscosity increases up to 10-fold. Mechanism: RBCs adhering to each other, and the vessel walls. • RBCs stick at constrictions, increase viscosity. • Concentration, distribution, shape, and rigidity of the suspended particles (e.g., RBCs drift to the center so velocity profile flattens from ideal parabolic) • Fahraeus-Lindqvist effect: reduced η when RBCs line up in small vessels (< 300 µm). • In very small vessels (< 20 µm), η increases as RBCs fill the capillaries, “tractor tread” motion • Temperature, blood pressure, presence of anticoagulants, • Measurement conditions: higher in vitro than in vivo. • History (pulsatile flow) Hemodynamics Bioengineering 6000 CV Physiology Velocity and Pressure • Example: Aortic stenosis – increased velocity ˙ ˙ ˙ ˙ ˙ ˙ – decreased lateral Q = Qo Q = Qo Q = Qo pressure v = vo v = kvo v = vo – reduced coronary Ptot = Po Ptot = Po Ptot = Po flow = Pdo + Plo = Pd + Pl – coronary ischemia 1 2 1 2 Pd = ⇢v P = ⇢(kv ) P = P 2 o d 2 o d do 2 = Pdo = k Pdo Pl = Plo P = P P Pl = Plo l tot − d <Plo Hemodynamics Bioengineering 6000 CV Physiology Aortic Stenosis • Pressure losses P (lower than – kinetic energy ao conversion normal) – energy loss (friction) Pavo Coronary Coronary artery artery Pv Left ventricle Hemodynamics Bioengineering 6000 CV Physiology Resistance of the Circulatory System • Resistance high where Cross-sectional area pressure drops Velocity • Arterioles have highest resistance • Paradox? Pressure – arterioles have more total area than arteries – vessels with larger area have smaller resistance – but arterioles have larger resistance than arteries? Aorta Arteries Arterioles Capillaries Venules Veins Venae Cava Velocity Cross-sectional area Pressure Percent of blood volume Hemodynamics Bioengineering 6000 CV Physiology Resistance-Area Paradox An,rn,Rn Aw =4An Aw,rw,Rw rw =2rn Rt • Net flow must be 1 4 1 4 constant = = R R R • One vessel 8⌘l k t 1=1 n n R = = X splitting to four ⇡r4 r4 R k increases total n Rt = = 4 resistance! 4 4rn k k k 1 k Rt Rw = 4 = 4 = 4 = 4 = rw (2rn) 16rn 4 ⇤ 4rn 4 Rt =4Rw! Hemodynamics Bioengineering 6000 CV Physiology Resistance Break Even Point • Break-even point at 16 to 1 (for Rw=Rt). • Capillaries have more than 16:1 ratio An,rn,Rn Aw,rw,Rw Rt At = 16An =4Aw Rw = Rt Hemodynamics Bioengineering 6000 CV Physiology.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    10 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us