5KW MONO PHASE SOLAR INVERTER Technical Parameter

5KW MONO PHASE SOLAR INVERTER Technical Parameter

5KW MONO PHASE SOLAR INVERTER Technical Parameter INVI1-5-6000BL 3KW MONO PHASE SOLAR INVERTER Technical Parameter INVI1-3-4600BL 7.5KW MONO PHASE SOLAR INVERTER Technical Parameter INVI1-75-8000BL 15KW MONO PHASE SOLAR INVERTER Technical Parameter SFSA-15KD 10KW MONO PHASE SOLAR INVERTER Technical Parameter 20KW MONO PHASE SOLAR INVERTER INVI1-10-10500BL Technical Parameter SFSA-20KD 3KW THREE PHASE SOLAR INVERTER Technical Parameter INVI3-3-8100B 50KW MONO PHASE SOLAR INVERTER Technical Parameter SFSA-50D 4KW THREE PHASE SOLAR INVERTER Technical Parameter INVI3-4-8700B 10KW THREE PHASE SOLAR INVERTER Technical Parameter INVI3-10-18000B 7.5KW THREE PHASE SOLAR INVERTER Technical Parameter INVI3-75-14600b 15KW THREE PHASE SOLAR INVERTER Technical Parameter SFSA-15KD 20KW THREE PHASE SOLAR INVERTER 50KW THREE PHASE SOLAR INVERTER Technical Parameter Technical Parameter SFSA-50KS SFSA-20KS Isolating: Transformer Rated Power (KW): 3 Max PV Module Power Allowed (KW): 3.3 Max Open Voltage (VDC): 570 Recommended PV Module Numbers: 16 loops (17V/module) MPPT Range (VDC): 150~450 Rated AC Output Power (KW): 3 Grid Voltage Range (VAC): 180~260/90~130 Rated Grid Frequency (Hz): 50/60Hz Max Efficiency: 94.00% European Standard Efficiency: 93.50% Display: LCD 3KW SOLAR INVERTER THD (Iac): THD (Iac)<4 % (full-capacity) Technical Parameter MPPT Precision: 99% Grid Monitoring: RS485 GSG-3KSL-TW Electromagnetic Compatibility: EN50081.part1/ EN50082.part1 Power Disruption: EN61000-3-2 Power Detection: DIN VDE 126 Cooling method: By fan Equipment Self-Consumption at night (W): 0 Operating Environment Temperature: ~20~~~50~ DC Voltage Ripple: Vpp < 10 % Operating Environment Humidity: 0~95% (non-condensing) Isolating: Transformer Waterproof and Dustproof Level: IP54 (outdoors) Reference Dimension (mm): 450×600×295 Rated Power (KW): 2 Prevent Island Method: Vac; Fac Reference Weight (KG): 73 Max PV Module Power Allowed (KW ): 2.2 Max Open Voltage (VDC): 570 Recommended PV Module Numbers: 16 loops (17V/module) MPPT Range (VDC): 150 ~450 Grid Voltage Range (VAC): 330~460/170~230 Rated AC Output Power (KW): 2 Rated Grid Frequency (Hz): 50 / 60Hz Grid Voltage Range (VAC): 180~260/90~130 Max Efficiency: 94.80% Rated Grid Frequency (Hz): 50/60Hz European Standard Efficiency: 93.50% Max Efficiency: 0.94 Display: LCD European Standard Efficiency: 0.935 10KW SOLAR INVERTER THD (Iac): THD (Iac)<4 % (full-capacity) Display: LCD 2KW SOLAR INVERTER Technical Parameter Power factor: ≥0.99 (half-capacity) THD (Iac): THD (Iac)<4 % (full capacity) Technical Parameter MPPT Precision: 99% Power Factor: ≥0.99 (above half-capacity) Grid monitoring: RS485 GSG-10KTL-TV MPPT Precision: 0.99 GSG-2KSL-TW Electromagnetic Compatibility: EN50081,part1/ Grid Monitoring RS: 485 EN50082,part1 Electromagnetic Compatibility: EN50081.part1/ EN50082.part1 Power disruption: EN61000-3-2 Power Disruption: EN61000-3-2 Power Detection: DIN VDE 126 Power Detection: Din VDE 126 Equipment self-consumption at night (W): 0 Equipment Self-Consumption at night (W): 0 DC voltage ripple: Vpp < 10 % DC Voltage Ripple: Vpp < 10 % Waterproof and Dustproof level: IP20 (indoors) / IP42 Waterproof and Dustproof Level: IP65 (outdoors) (outdoors) Prevent Island Method: Vac; Fac Isolating: Transformer Prevent island method: Vac; Fac Cooling Method : By fan Rated Power (KW): 10 Cooling method: By fan Operating Environment Temperature: ~20~~~50~ The max PV module power allowed (KW): 11 Operating Environment Temperature: ~20~~~50~ Operating Environment Humidity: 0~95% (Non-Condensing) Max Open Voltage (VDC): 850 Operating Environment Humidity: 0~95% (non- Reference Dimension (mm): 346×425×213 Recommended PV module numbers: 16 loops (17V/module) condensing) Reference Weight (KG): 36 MPPT range (VDC): 250~800 @ 272 Reference Dimension (mm): 500×600×1300 Rated AC output power (KW): 10 Reference Weight (KG): 230 Rated AC Output Power (KW): 50 Grid Voltage Range (VAC): 330~460/170~230 Rated Grid Frequency (Hz): 50/60Hz Max Efficiency: 96.00% European Standard Efficiency: 95.50% 50KW SOLAR INVERTER Display: Touch Screen Technical Parameter THD (Iac): THD (Iac)<4 % (full-capacity) Power Factor: ≥0.99(above capacity) MPPT Precision: 99% GSG-50KTL-TV Grid Monitoring: RS232 Interface/RS485 option Electromagnetic Compatibility: EN50081, part1/ EN50082, part1 Power Disruption: EN61000-3-2 Power Detection: DIN VDE 126 Equipment Self-Consumption at night (W): < 20 DC Voltage Ripple: Vpp < 10 % Waterproof and Dustproof Level: IP20 (Indoors) / IP42 (outdoors) Isolating: Transformer Prevent Island Method: Vac; Fac Rated Power (KW): 50 Cooling Method: By fan Isolating: Transformer The max PV module power allowed (KW): 55 Operating Environment Temperature: -20~ C~+50 C Rated Power (KW): 30 Max Open Voltage (VDC) : 850 Operating Environment Humidity: 0~95% (non-condensing) The max PV module power allowed (KW): 33 Recommended PV Module Numbers: 16loops (35V/module) Reference Dimension (mm): 600×800×1600 Max Open Voltage (VDC): 850 MPPT Range (VDC): 440~800 Reference Weight (KG): 530 Recommended PV Module Numbers: 16loops (35V/module) MPPT Range (VDC): 440~800 Rated AC Output Power (KW): 30 Isolating: Transformer Grid Voltage Range (VAC): 330~460/170~230 Rated Power (KW): 100 Rated Grid Frequency (Hz): 50/60Hz Max PV Module Power Allowed (KW): 110 Max Efficiency: 94.50% Max Open Voltage (VDC): 850 European Standard Efficiency: 93.60% Recommended PV Module Numbers: 16loops (35V/ Display: LCD module) 100 KW SOLAR INVERTER THD (Iac): THD (Iac)<4 % (full-capacity) MPPT Range (VDC): 440~800 Technical Parameter Power Factor: ≥0.99(above half-capacity) Rated AC Output Power (KW): 100 MPPT Precision: 99% Grid Voltage Range (VAC): 330~460/170~230 Grid Monitoring: RS232 Interface/RS485 option GSG-100KTT-TV 30KW SOLAR INVERTER Rated Grid Frequency (Hz): 50 / 60Hz Electromagnetic Compatibility: EN50081, part1/ EN50082, part1 Technical Parameter Max Efficiency: 96.70% Power Disruption: EN61000-3-2 European Standard Efficiency: 96.00% Power Detection: DIN VDE 126 Display: Touch Screen GSG-30KTL-TV Equipment Self-Consumption at night (W): < 20 THD (Iac): THD (Iac)<4 % (Full Capacity) DC Voltage Ripple: Vpp < 10 % Power Factor: ≥0.99 (above half capacity) Waterproof and Dustproof Level: IP20 (Indoors) / IP42 (outdoors) MPPT Precision: 99% Prevent Island Method: Vac; Fac Grid Monitoring: RS232 Interface/RS485 Option Waterproof And Dustproof Level: IP20(indoors) / IP42(outdoors) Cooling Method: By fan Electromagnetic Compatibility: EN50081, part1/ Prevent Island Method: Vac; Fac Operating Environment Temperature: ~20~~~50~ EN50082, part1 Cooling Method: By fan Operating Environment Humidity: 0~95% (non-condensing) Power Disruption: EN61000-3-2 Operating Environment Temperature: ~20~~~50~ Reference Dimension (mm): 600×800×1600 Power Detection: DIN VDE 126 Operating Environment Humidity: 0~95%(non-condensing) Reference Weight (KG): 420 Equipment Self-Consumption at night(W): < 20W Reference Dimension (mm): 800×1000×2100 DC Voltage Ripple: Vpp < 10 % Reference Weight (KG): 1200 Isolating: Transformer Isolating: Transformer less Rated Power (Kw): 250 Rated Power (KW): 250 The Max PV Module Power Allowed (KW) : 275 The max PV module power allowed (KW): 275 Max Open Voltage (Vdc): 850 Max Open Voltage (VDC): 850 Recommended PV Module Numbers: 16 loops (35V/module) Recommended PV Module Numbers: 16loops (35V/module) MPPT Range (VDC): 440 ~ 800 MPPT Range (VDC): 440 ~ 800 Rated AC Output Power (KW): 250 Rated AC Output Power (KW): 250 Grid Voltage Range (VAC): 330~ 460 Grid Voltage Range (VAC): 230 ~ 300 Rated Grid Frequency (Hz): 50 / 60Hz Rated Grid Frequency (Hz): 50 / 60Hz Max Efficiency: 97.00% Max Efficiency: 98.20% European Standard Efficiency: 95.80% European Standard Efficiency: 97.50% Display: Touch Screen Display: Touch Screen THD (Iac): THD (Iac)<4 % (full-capacity) THD (Iac): THD (Iac)<4 % (full-capacity) Power Factor: ≥0.99 (above half-capacity) Power Factor: ≥0.99 (above half-capacity) MPPT Precision: 99% Mppt Precision: 99% Grid monitoring: RS232 Interface/RS485 option 250KW SOLAR INVERTER Grid Monitoring: RS232 Interface/RS485 option 250KW SOLAR INVERTER Electromagnetic Compatibility: EN50081, part1/EN50082, part1 Technical Parameter Electromagnetic Compatibility: EN50081,part1/EN50082,part1 Technical Parameter Power Disruption: EN61000-3-2 Power Disruption : EN61000-3-2 Power Detection: DIN VDE 126 Power Detection: DIN VDE 126 GSG-250KTT-TV GSG-250KTT-TV Equipment Self-Consumption At Night (W): < 50 Equipment self-consumption at night (W): < 50 DC Voltage Ripple: Vpp < 10 % DC Voltage Ripple: Vpp < 10 % Waterproof And Dustproof Level: IP20 (indoors) / IP42 (outdoors) Waterproof And Dustproof Level: IP20 (indoors)/IP42 (outdoors) Prevent Island Method: Vac; Fac Prevent Island Method: Vac; Fac Cooling Method: By fan Cooling Method: By fan Operating Environment Temperature: -20 C ~ 50 C Operating Environment Temperature: -20 C ~ +50 C Operating Environment Humidity: 0~ 95% (non-condensing) Operating Environment Humidity: 0 ~ 95% (non-condensing) Reference Dimension (mm): 840×1810×2160 Reference Dimension (mm): 860×1210×2160 Reference Weight (KG): 2000 Reference Weight (KG): 1000 Height of tower (m): 6 Blade diameter (m): 2 Weight of top section (kg): 27 Rated Rotated speed (r/m): 400 controller Parameter: 24V 40A Rated wind speed (m/s): 8 Inverter Parameter: DC24V (user’s local Rated power (w): 200 voltage & frequency) Max power (w): 300 tower pole type (mm): ~60*3 Output voltage (v): 24 20container (sets): 120 Start up wind speed

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    69 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us